ECHELON ENDOPATH GST45WRecalls & reported problems
Ethicon Endo-Surgery, LLC · The ECHELON, ECHELON ENDOPATH™ and ECHELON FLEX™ families of endoscopic linear cutters and reloads are sterile, single patient use instruments that simultaneously cut and staple tissue. There are six staggered rows of staples, three on either side of the cut line. The 45 mm instruments have a staple line thatis approximately 45 mm long and a cut line that is approximately 42 mm long. The shaft can rotate freely in both directions and an articulation mechanism on articulating instruments enables bending the distal portionof the shaft to facilitate lateral access of the operative site.The instruments are shipped without a reload and must be loaded prior to use. A staple retaining cap on the reload protects the staple leg points during shipping and transportation. The instruments’ lock-out feature is designed to prevent a used reload from being refired. · Class 2 · Implant
All models of ECHELON ENDOPATH (31)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
Quick summary
This Ethicon Echelon Endopath stapler is a single-use instrument that cuts and staples tissue during surgery. Of the 160 reports, many describe staples that do not form properly or the stapler failing to fire. The reports include 1 death and 39 injuries. There is 1 open recall, started in December 2023, over staples that may not form fully and could cause bleeding.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 163
- Deaths reported
- 1
- Injuries reported
- 39
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 163 adverse event reports that list this exact device (DI 10705036014928), received between Jan 31, 2018 and Sep 28, 2026 — classified as 1 death, 39 injuries, 123 malfunctions.
The most frequently reported specific device problem is “Failure to Form Staple” (53 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Recalls naming this device
- Dec 11, 2023Open, Classified
There is the potential for incomplete staple line formation during the firing sequence, without most or all staples, which may lead to insufficient tissue apposition that could require surgical intervention. This may result in bleeding, prolonged surgery, or surgical delay.
Z-0834-2024 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported problems
Device problems
- Failure to Form Staple53
- Adverse Event Without Identified Device or Use Problem35
- Material Integrity Problem20
- Failure to Fire17
- No Apparent Adverse Event10
- Ejection Problem7
- Separation Problem5
- Device Markings/Labelling Problem4
Patient problems
- No Clinical Signs, Symptoms or Conditions114
- Hemorrhage/Blood Loss/Bleeding33
- No Consequences Or Impact To Patient8
- Blood Loss6
- No Code Available5
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available2
- Ecchymosis2
- Insufficient Information2
Recent adverse event reports
The 25 most recent of 163 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 28, 2026Failure to Form Staple
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50916695 ↗MalfunctionSep 20, 2026Device Markings/Labelling Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50834833 ↗MalfunctionSep 20, 2026Device Markings/Labelling Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50834832 ↗MalfunctionAug 24, 2026Failure to Fire
It was reported that during an unspecified surgical procedure, it was observed that the device could not be fired properly. There was no patient consequence nor surgical delay reported. No additional information provided.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50409146 ↗MalfunctionJul 27, 2026Failure to Form Staple; No Apparent Adverse Event
Patient problems: Hemorrhage/Blood Loss/Bleeding; No Clinical Signs, Symptoms or Conditions
MAUDE report 50011982 ↗MalfunctionJul 13, 2026Failure to Form Staple; No Apparent Adverse Event
IT WAS REPORTED THAT DURING A LUNG RESECTION, IT WAS OBSERVED THAT A FEW STAPLES WERE FORMED WITH IRREGULAR SHAPES AFTER FIRING; AND ANASTOMOTIC SITE WAS OOZING. SUTURE WAS USED TO OVERSEW. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION COULD BE PROVIDED.
Patient problems: Hemorrhage/Blood Loss/Bleeding; No Clinical Signs, Symptoms or Conditions
MAUDE report 25798166 ↗MalfunctionJun 15, 2026Failure to Form Staple
IT WAS REPORTED THAT DURING A LUNG RESECTION PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. THEY USED SUTURE TO OVERSEW. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION CAN BE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25510948 ↗InjuryJun 8, 2026Patient Device Interaction Problem
IT WAS REPORTED THAT DURING A GASTRIC BYPASS THE DOCTOR SAID EVERYTHING WENT WELL AT FIRST GLANCE, WHEN HE IS GOING TO PERFORM THE POSTOPERATIVE CONTROL THE SAME DAY IN THE AFTERNOON HE NOTICES THE PATIENT WITH HER HEMODYNAMIC PARAMETERS ALTERED, THEY PERFORM AN ENDOSCOPY TO CHECK IF THERE IS ANY PROBLEM WITH THE SURGERY AND HE REALIZES THAT CLOSE TO THE STAPLE LINE OF THE GASTRIC POUCH AND THE GASTROJEJUNAL ANASTOMOSIS THAT HE PERFORMS MANUALLY, THE PATIENT HAS BRUISES AND CLOTS. WAS THERE ANY HARM TO THE REPORTED PATIENT OR USER? YES. DID THE PATIENT/USER REQUIRE ANY MEDICAL OR SURGICAL INTERVENTION AS A RESULT OF THE EVENT? YES. DESCRIPTION: THE PATIENT HAD TO UNDERGO SURGERY AGAIN, SINCE IN THE POSTOPERATIVE PERIOD THE DOCTOR PERFORMED AN ENDOSCOPY AND SHOWED THAT THE PATIENT HAD BRUISES AND CLOTS IN THE GASTROJEJUNAL ANASTOMOSIS, SO IT WAS DECIDED TO OPERATE ON HER AGAIN. DID THE PATIENT/USER REQUIRE PROLONGED HOSPITALIZATION AS A RESULT OF THE EVENT? UNKNOWN. WHAT IS THE PATIENT/USER STATUS AFTER THE EVENT? NOW IT'S OKAY. WAS THERE A SIGNIFICANT DELAY?
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Ecchymosis
MAUDE report 25428825 ↗InjuryJun 8, 2026Patient Device Interaction Problem
IT WAS REPORTED THAT DURING A GASTRIC BYPASS THE DOCTOR SAID EVERYTHING WENT WELL AT FIRST GLANCE, WHEN HE IS GOING TO PERFORM THE POSTOPERATIVE CONTROL THE SAME DAY IN THE AFTERNOON HE NOTICES THE PATIENT WITH HER HEMODYNAMIC PARAMETERS ALTERED, THEY PERFORM AN ENDOSCOPY TO CHECK IF THERE IS ANY PROBLEM WITH THE SURGERY AND HE REALIZES THAT CLOSE TO THE STAPLE LINE OF THE GASTRIC POUCH AND THE GASTROJEJUNAL ANASTOMOSIS THAT HE PERFORMS MANUALLY, THE PATIENT HAS BRUISES AND CLOTS. WAS THERE ANY HARM TO THE REPORTED PATIENT OR USER? YES DID THE PATIENT/USER REQUIRE ANY MEDICAL OR SURGICAL INTERVENTION AS A RESULT OF THE EVENT? YES. DESCRIPTION: THE PATIENT HAD TO UNDERGO SURGERY AGAIN, SINCE IN THE POSTOPERATIVE PERIOD THE DOCTOR PERFORMED AN ENDOSCOPY AND SHOWED THAT THE PATIENT HAD BRUISES AND CLOTS IN THE GASTROJEJUNAL ANASTOMOSIS, SO IT WAS DECIDED TO OPERATE ON HER AGAIN. DID THE PATIENT/USER REQUIRE PROLONGED HOSPITALIZATION AS A RESULT OF THE EVENT? UNKNOWN WHAT IS THE PATIENT/USER STATUS AFTER THE EVENT? NOW IT'S OKAY. WAS THERE A SIGNIFICANT DELAY?
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Ecchymosis
MAUDE report 25428824 ↗MalfunctionJun 2, 2026Delivered as Unsterile Product
IT WAS REPORTED THAT PREOPERATIVELY TO AN UNSPECIFIED SURGICAL PROCEDURE, IT WAS OBSERVED THAT THE PACKAGING OF THE DEVICE WAS DAMAGED. CHANGED TO ANOTHER TWO TO CONTINUE THE PROCEDURE BUT THE SAME PROBLEM HAPPENED AGAIN. ANOTHER DEVICE WAS USED TO COMPLETE THE SURGERY. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION COULD BE PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25364857 ↗MalfunctionMay 29, 2026Failure to Form Staple
IT WAS REPORTED THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25336738 ↗MalfunctionMay 29, 2026Failure to Form Staple
IT WAS REPORTED THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25333147 ↗MalfunctionMay 29, 2026Failure to Form Staple
IT WAS REPORTED THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25332235 ↗MalfunctionApr 21, 2026Failure to Form Staple
IT WAS REPORTED THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24945001 ↗MalfunctionApr 9, 2026Failure to Form Staple
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE, IT WAS OBSERVED THAT SOME STAPLES WERE MALFORMED WITH IRREGULAR SHAPE (WITH STRAIGHT LEG) AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE PROCEDURE AND USED SUTURE TO OVERSEW. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24835401 ↗MalfunctionFeb 17, 2026No Apparent Adverse Event
IT WAS REPORTED THAT THE CUSTOMER RECEIVED ALLEGEDLY DEFECTIVE PRODUCTS. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24366570 ↗MalfunctionFeb 9, 2026No Apparent Adverse Event
IT WAS REPORTED THAT THE CUSTOMER RECEIVED ALLEGEDLY DEFECTIVE PRODUCTS. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24298468 ↗MalfunctionFeb 6, 2026Failure to Form Staple
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24283074 ↗MalfunctionFeb 6, 2026Failure to Form Staple
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE, IT WAS OBSERVED THAT THE STAPLES WERE MALFORMED AFTER FIRING. CHANGED TO A NEW ONE TO COMPLETE THE PROCEDURE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24282708 ↗MalfunctionJan 16, 2026Manufacturing, Packaging or Shipping Problem
IT WAS REPORTED THAT DURING A THORACOSCOPIC PULMONARY SEGMENTECTOMY, WHEN THE CIRCULATING NURSE OPENED THE CARTRIDGE PACKAGE AND GAVE IT TO THE SCRUB NURSE, THE CARTRIDGE PAN WAS BROKEN. THE SALES REP ATTENDED THE OPERATION AND DETERMINED THAT THERE WAS NO NEGLIGENCE ON THE PART OF THE NURSE AND THAT THE PROBLEM WAS DUE TO A PRODUCT ASSEMBLY FAILURE. AS IT HAD NOT YET BEEN USED, THERE WAS NO IMPACT ON THE PATIENT. THE CARTRIDGE COLOR WAS WHITE. ANOTHER DEVICE WAS USED TO COMPLETE THE CASE. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24100016 ↗MalfunctionJan 7, 2026Separation Problem
IT WAS REPORTED THAT DURING AN UNKNOWN LAPAROSCOPIC UROLOGICAL PROCEDURE, THE CARTRIDGE WAS USED AT THE 1ST FIRING, AND THE CARTRIDGE WOULD NOT FIT PROPERLY WHEN TRYING TO LOAD THE 2ND FIRING. AFTER TRYING SEVERAL TIMES AND STILL NOT BEING ABLE TO LOAD, IT WAS FOUND THAT THE CARTRIDGE PAN (WHICH HAD ALREADY BEEN SENT AS A DEFECT) WAS STILL LEFT TO THE MAIN BODY WHEN CHECKED THE MAIN BODY. THE PART REMAINING IN THE MAIN BODY WAS REMOVED WITH FORCEPS AND LOADED. THE DOCTOR WANTED TO KNOW WHY THIS WAS POSSIBLE. THE CARTRIDGE COLOR WAS WHITE. ANOTHER DEVICE WAS USED TO COMPLETE THE CASE. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23990041 ↗MalfunctionJan 6, 2026Ejection Problem
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE, IT WAS OBSERVED THAT THE GST45W RELOAD COULD NOT MATCH WITH THE GST GUN. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23975681 ↗MalfunctionDec 2, 2025Delivered as Unsterile Product; Delivered as Unsterile Product
IT WAS REPORTED THAT DURING A GASTROPLASTY PROCEDURE, DURING THE OPENING OF THE KIT, A PACKAGE WAS IDENTIFIED CONTAINING ONE LOOSE STAPLE INSIDE THE SEAL, COMPROMISING THE USE OF THE PACKAGE. THERE WAS NO PATIENT CONSEQUENCE NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23693471 ↗MalfunctionNov 26, 2025No Apparent Adverse Event; No Apparent Adverse Event
IT WAS REPORTED BY THE KEY ACCOUNT MANAGER THAT THE CLINIC RECEIVED BATCHES OF PRODUCTS (SPECIFIED IN THE CONTRACT AS ETHICON PRODUCTS) THAT WERE NOT SHIPPED TO OUR WAREHOUSE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23657203 ↗MalfunctionNov 11, 2025No Apparent Adverse Event; No Apparent Adverse Event
IT WAS REPORTED THAT THE CUSTOMER RECEIVED ALLEGEDLY DEFECTIVE PRODUCTS. THERE WAS NO PATIENT CONSEQUENCE REPORTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23524445 ↗
Other STAPLE, IMPLANTABLE devices
- Endo GIA EGIA60AMTCovidien LP · STAPLE, IMPLANTABLE19 deaths10,680 reports
- Endo GIA Ultra EGIAUSTNDCovidien LP · STAPLE, IMPLANTABLE5 deaths9,730 reports
- Signia SIGPHANDLECovidien LP · STAPLE, IMPLANTABLE1 recall3 deaths5,356 reports
- ECHELON FLEX PSEE60AEthicon Endo-Surgery, LLC · STAPLE, IMPLANTABLE1 recall13 deaths3,294 reports
- Endo GIA Ultra EGIAUSHORTCovidien LP · STAPLE, IMPLANTABLE2 deaths3,011 reports
- Endo GIA EGIA45AMTCovidien LP · STAPLE, IMPLANTABLE10 deaths2,965 reports
- Endo GIA Ultra EGIAUXLCovidien LP · STAPLE, IMPLANTABLE2,909 reports
- ENDOPATH ATS45Ethicon Endo-Surgery, LLC · STAPLE, IMPLANTABLE2 deaths2,046 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page