D.A.S.H. G34779Recalls & reported problems
Cook Incorporated · D.A.S.H. Preloaded with Acrobat Wire Guide · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10827002347790), received between Oct 21, 2016 and Feb 28, 2017 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Peeled/Delaminated” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Peeled/Delaminated2
Patient problems
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 28, 2017Peeled/Delaminated; Peeled/Delaminated
DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP), THE PHYSICIAN USED A COOK DASH PRE-LOADED WITH ACROBAT WIRE GUIDE SPHINCTEROTOME. AFTER SEVERAL EXCHANGES, THE COATING AROUND THE WIRE GUIDE BEGAN TO STRIP OFF REVEALING THE CORE OF THE WIRE GUIDE [COATING DAMAGE]. THE TECHNICIAN NOTICED ON FLUOROSCOPY WHAT LOOKED LIKE A SPRING AT THE TIP OF THE WIRE GUIDE. THEY REMOVED IT AND REALIZED THE COATING HAD STRIPPED OFF. THE WIRE GUIDE WAS INTACT, NO PIECES OR PARTS BROKE OFF, AND THERE WAS NOTHING LEFT BEHIND IN THE PATIENT NOR WAS THERE ANY HARM TO THE PATIENT AS A RESULT OF THE WIRE STRIPPING. THEY WERE ABLE TO USE ANOTHER WIRE AND COMPLETE THE PROCEDURE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6364348 ↗MalfunctionOct 21, 2016Peeled/Delaminated; Peeled/Delaminated
DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP), THE PHYSICIAN USED A COOK D.A.S.H. PRE-LOADED WITH ACROBAT WIRE GUIDE. THE TIP OF THE WIRE GUIDE GOT [A] TEAR [COATING DAMAGE AT DISTAL END]. SUBSEQUENTLY, THE DEVICE WAS REMOVED FROM THE PATIENT [DEVICE WAS TAKEN OUT DUE TO THE COATING DAMAGE].
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6048400 ↗
Other Unit, electrosurgical, endoscopic (with or without accessories) devices
- THUNDERBEAT 5 mm, 35 cm, Front-actuated Grip TB-0535FCOlympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)1 recall2 deaths404 reports
- SONICBEAT 5 mm, 35 cm, Front-actuated Grip SB-0535FCOlympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)379 reports
- Single Use Electrosurgical Knife KD-611LOlympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)1 death357 reports
- Autotome™ RX 44 M00545170Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)1 recall262 reports
- TRUEtome 44 M00584170Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)237 reports
- Dreamtome™ RX 44 M00584040Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)1 recall165 reports
- Dreamtome™ RX 44 M00584050Boston Scientific Corporation · Unit, electrosurgical, endoscopic (with or without accessories)1 recall127 reports
- Single Use 3-Lumen Sphincterotome V KD-V411M-0725Olympus Medical Systems Corp. · Unit, electrosurgical, endoscopic (with or without accessories)160 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page