LigaSure LF2019Recalls & reported problems
Covidien LP · LIGASURE EXACT DISSECTOR · Class 2
All models of LigaSure (32)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
Quick summary
This Covidien LigaSure Exact Dissector is an electrosurgical instrument that seals and cuts tissue. The 936 reports mostly describe parts detaching or peeling, weak or missing energy output, and some note the jaws locking closed while still delivering energy. Some mention bleeding and burns. The reports include no deaths and 73 injuries, and no recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 929
- Deaths reported
- 0
- Injuries reported
- 73
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 929 adverse event reports that list this exact device (DI 10884521741096), received between Mar 28, 2018 and Jun 26, 2026 — classified as 73 injuries, 856 malfunctions.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (419 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component419
- Energy Output Problem282
- Peeled/Delaminated201
- Retraction Problem60
- Device Alarm System55
- Difficult to Open or Close50
- Intermittent Energy Output47
- Break46
Patient problems
- No Clinical Signs, Symptoms or Conditions610
- No Consequences Or Impact To Patient168
- Insufficient Information61
- Hemorrhage/Blood Loss/Bleeding30
- Burn(s)14
- No Information14
- Device Embedded In Tissue or Plaque11
- No Code Available11
Recent adverse event reports
The 25 most recent of 929 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 26, 2026Self-Activation or Keying; Difficult to Open or Close; Intermittent Energy Output
IT WAS REPORTED THAT DURING A PROCEDURE, THE DEVICE WAS USED AND AFTER SOME TIME OF USE, THE DEVICE LOCKED IN THE CLOSED POSITION AND CONTINUED TO DELIVER COAGULATION UNINTERRUPTEDLY. THE DEVICE WAS REPLACED BY TWO OTHER DEVICES OF THE SAME REFERENCE/BATCH THAT SHOWED THE SAME MALFUNCTION DURING THE OPERATION. CHANGED THE DEVICE TO PREVENT PERMANENT INJURY OR IMPAIRMENT. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25638854 ↗MalfunctionJun 26, 2026Self-Activation or Keying; Difficult to Open or Close; Intermittent Energy Output
IT WAS REPORTED THAT DURING A PROCEDURE, THE DEVICE WAS USED AND AFTER SOME TIME OF USE, THE DEVICE LOCKED IN THE CLOSED POSITION AND CONTINUED TO DELIVER COAGULATION UNINTERRUPTEDLY. THE DEVICE WAS REPLACED BY TWO OTHER DEVICES OF THE SAME REFERENCE/BATCH THAT SHOWED THE SAME MALFUNCTION DURING THE OPERATION. CHANGED THE DEVICE TO PREVENT PERMANENT INJURY OR IMPAIRMENT. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25638806 ↗MalfunctionJun 26, 2026Self-Activation or Keying; Difficult to Open or Close; Intermittent Energy Output
IT WAS REPORTED THAT DURING A PROCEDURE, THE DEVICE WAS USED AND AFTER SOME TIME OF USE, THE DEVICE LOCKED IN THE CLOSED POSITION AND CONTINUED TO DELIVER COAGULATION UNINTERRUPTEDLY. THE DEVICE WAS REPLACED BY TWO OTHER DEVICES OF THE SAME REFERENCE/BATCH THAT SHOWED THE SAME MALFUNCTION DURING THE OPERATION. CHANGED THE DEVICE TO PREVENT PERMANENT INJURY OR IMPAIRMENT. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25638741 ↗MalfunctionJun 17, 2026Energy Output Problem
IT WAS REPORTED THAT DURING A THYROIDECTOMY/THYROID GLAND RESECTION PROCEDURE WITH A USE OF THE DEVICE WITH A GENERATOR CONNECTED, INADEQUATE OR PARTIAL SEALING OCCURRED WITH EVIDENCE OF ENERGY DELIVERY AND END TONES HEARD, AND THE SEAL WAS REPORTED TO BLEED AFTER CUTTING. THE SEALING WAS POOR AND IT WAS STILL BLEEDING. ANOTHER DEVICE WAS REPORTED TO HAVE BEEN USED SUCCESSFULLY WITH THE SAME GENERATOR.
Patient problems: Hemorrhage/Blood Loss/Bleeding
MAUDE report 25528811 ↗MalfunctionJun 15, 2026Energy Output Problem
IT WAS REPORTED THAT DURING A PROCEDURE, THE DEVICE HAD SEALING INADEQUATE/PARTIAL (WITH EVIDENCE OF ENERGY DELIVERY AND END TONES H EARD). ANOTHER DEVICE USED SUCCESSFULLY WITH THE SAME GENERATOR. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25498258 ↗MalfunctionJun 15, 2026Peeled/Delaminated; Device Damaged Prior to Receipt by User; Detachment of Device or Device Component
IT WAS REPORTED THAT PRIOR TO USE, ALL SIX DEVICES ARRIVED BROKEN AND WERE IN UNUSABLE CONDITION. THE PHOTO SUBMITTED SHOWS TIP OF THE DEVICES WERE DAMAGED AND ONE DEVICE TIP HAD BROKEN OFF. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25498229 ↗MalfunctionJun 15, 2026Peeled/Delaminated; Device Damaged Prior to Receipt by User; Detachment of Device or Device Component
IT WAS REPORTED THAT PRIOR TO USE ALL SIX DEVICES ARRIVED BROKEN AND WERE IN UNUSABLE CONDITION. THE PHOTO SUBMITTED SHOWS TIP OF THE DEVICES WERE DAMAGED AND ONE DEVICE TIP HAD BROKEN OFF. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25498217 ↗MalfunctionJun 15, 2026Peeled/Delaminated; Device Damaged Prior to Receipt by User; Detachment of Device or Device Component
IT WAS REPORTED THAT PRIOR TO USE, ALL SIX DEVICES ARRIVED BROKEN AND WERE IN UNUSABLE CONDITION. THE PHOTO SUBMITTED SHOWS TIP OF THE DEVICES WERE DAMAGED AND ONE DEVICE TIP HAD BROKEN OFF. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25498210 ↗MalfunctionJun 15, 2026Peeled/Delaminated; Device Damaged Prior to Receipt by User; Detachment of Device or Device Component
IT WAS REPORTED THAT PRIOR TO USE, ALL SIX DEVICES ARRIVED BROKEN AND WERE IN UNUSABLE CONDITION. THE PHOTO SUBMITTED SHOWS TIP OF THE DEVICES WERE DAMAGED AND ONE DEVICE TIP HAD BROKEN OFF. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25498193 ↗MalfunctionJun 10, 2026Peeled/Delaminated; Detachment of Device or Device Component
IT WAS REPORTED THAT, DURING THYROIDECTOMY SURGERY, THE TIP OF THE HANDPIECE BROKE OFF.
Patient problems: Insufficient Information
MAUDE report 25457728 ↗MalfunctionJun 2, 2026Peeled/Delaminated; Device Damaged Prior to Receipt by User; Detachment of Device or Device Component
IT WAS REPORTED THAT PRIOR TO USE, ALL SIX DEVICES ARRIVED BROKEN AND WERE IN UNUSABLE CONDITION. THE PHOTO SUBMITTED SHOWED THAT THE TIPS OF THE DEVICES WERE DAMAGED, AND THE TIP OF ONE DEVICE HAD BROKEN OFF. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25362377 ↗MalfunctionApr 30, 2026Peeled/Delaminated; Detachment of Device or Device Component
IT WAS REPORTED THAT, DURING PROCEDURE, THE TIP OF THE DEVICE CHIPPED OFF. A NEW DEVICE WAS OPENED WITH THE SAME ISSUE. THE TIP WAS RETRIEVED. THERE WAS NO PATIENT HARM/INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25046301 ↗MalfunctionApr 30, 2026Peeled/Delaminated; Detachment of Device or Device Component
IT WAS REPORTED THAT, DURING PROCEDURE, THE TIP OF THE DEVICE CHIPPED OFF. A NEW DEVICE WAS OPENED WITH THE SAME ISSUE. THE TIP WAS RETRIEVED. THERE WAS NO PATIENT HARM/INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25046024 ↗MalfunctionApr 30, 2026Peeled/Delaminated; Detachment of Device or Device Component; Insufficient Device Problem Information
IT WAS REPORTED THAT, DURING A PROCEDURE, THE TIP OF THE HANDPIECE CHIPPED OFF. A SECOND DEVICE WAS OPENED AND USED BUT HAD THE SAME ISSUE. TIP WAS RETRIEVED. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25045679 ↗MalfunctionApr 30, 2026Peeled/Delaminated; Detachment of Device or Device Component; Insufficient Device Problem Information
IT WAS REPORTED THAT, DURING A PROCEDURE, THE TIP OF THE HANDPIECE CHIPPED OFF. A SECOND DEVICE WAS OPENED AND USED BUT HAD THE SAME ISSUE. TIP WAS RETRIEVED. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25045575 ↗MalfunctionApr 27, 2026Peeled/Delaminated; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING PROCEDURE, EXPOSED WIRES WERE OBSERVED ON THE DEVICE'S JAWS. THE DEVICE WAS PLUGGED INTO A GENERATOR AT THE TIME OF THE EVENT, AND ANOTHER DEVICE WAS USED SUCCESSFULLY WITH THE SAME GENERATOR. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. MEDTRONIC'S INITIAL EVALUATION OF THE INCIDENT DEVICE FOUND THAT THE TIP OF THE JAW WAS DAMAGED AND MATERIAL WAS MISSING, EXPOSING THE METAL UNDERNEATH.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24998864 ↗MalfunctionApr 10, 2026Peeled/Delaminated; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING A NECK DISSECTION PROCEDURE, THE TOP OF THE JAW HAD A BROKEN PLASTIC, AND PLASTIC WAS CHIPPED OFF. THE KNIFE BLADE WAS NOT EXTENDED AND DID NOT PROTRUDE BEYOND THE EDGE OF THE JAWS. THE PIECE OF PLASTIC WAS LOCATED AND REMOVED WITHOUT INJURY.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 24841897 ↗MalfunctionApr 10, 2026Peeled/Delaminated; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING AN OPEN NECK DISSECTION, THE EXACT DISSECTOR LIGASURE 21 CM WAS PLUGGED INTO A GENERATOR WHEN A JAW ISSUE OCCURRED IN WHICH THE TIP OF THE JAW CRACKED AND FELL OFF. IT WAS REPORTED THAT PLASTIC FROM THE JAW FELL INTO THE PATIENT AND THE FOREIGN PLASTIC PIECE HAD TO BE RETRIEVED FROM THE PATIENT DURING THE PROCEDURE. NO ADDITIONAL INTERVENTION WAS NEEDED SUCH AS X-RAY TO RETRIEVE THE BROKEN PIECE. THE PATIENT WAS REPORTED TO BE ALIVE WITH NO INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24841895 ↗MalfunctionApr 10, 2026
INCOMPLETE SEAL CYCLE ERROR---2 DEVICES: LOT # 60070164X, EXP 01.06.2031. LOT# 52320234X, EXP 08.19.2030.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24839064 ↗MalfunctionApr 7, 2026Peeled/Delaminated; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING A PROCEDURE, THE TIP OF TWO HANDPIECES BROKE OFF IN PATIENT. THE BROKEN PIECE WAS RECOVERED WITH NO X-RAY OR EXTRA STEPS NEEDED. ANOTHER HANDPIECE WAS USED WITH THE SAME GENERATOR AND IT WORKED FINE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24797925 ↗MalfunctionApr 7, 2026Peeled/Delaminated; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING A PROCEDURE, THE TIP OF TWO HANDPIECES BROKE OFF IN PATIENT. THE BROKEN PIECE WAS RECOVERED WITH NO X-RAY OR EXTRA STEPS NEEDED. ANOTHER HANDPIECE WAS USED WITH THE SAME GENERATOR AND IT WORKED FINE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24797845 ↗InjuryApr 6, 2026Peeled/Delaminated; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING A PAROTIDECTOMY CASE, THE DEVICE¿S TIP CHIPPED OFF BY 0.1 CM. THE BREAKAGE WAS NOTICED AFTER CLEANING THE TIP WITH A SALINE WET SWAB. THE SURGEON WAS INFORMED, AND A SEARCH WAS CONDUCTED AROUND THE AREA AND SWABS USED, BUT NOTHING WAS FOUND. THE SURGEON DETERMINED THAT THE FRAGMENT WAS VERY SMALL AND DECIDED THERE WAS NO NEED TO PERFORM X-RAY. NO FURTHER DAMAGE WAS NOTED DURING THE CASE. THE DEVICE WAS CLEANED AFTER USE AND KEPT IN THE TEAM LEADER'S OFFICE, AND THE MATRON WAS INFORMED. THERE WAS NO PATIENT INJURY. PHOTOGRAPH WAS RECEIVED AND SHOWED THAT THE DEVICE¿S INSULATION TIP WAS BROKEN OFF.
Patient problems: Foreign Body In Patient
MAUDE report 24792002 ↗MalfunctionApr 6, 2026Detachment of Device or Device Component
IT WAS REPORTED THAT DURING AN OPEN PARATHYROID SURGERY WITH NECK DISSECTION, A DEVICE WAS BEING USED WHILE PLUGGED INTO A GENERATOR WHEN A COMPONENT ISSUE OCCURRED, IN WHICH A PIECE OF THE JAW BROKE OFF THE DEVICE AND WAS RETRIEVED WITHOUT ISSUE. ANOTHER DEVICE WAS REPORTED TO HAVE BEEN USED SUCCESSFULLY WITH THE SAME GENERATOR. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24791233 ↗MalfunctionApr 1, 2026Device Alarm System; Energy Output Problem
IT WAS REPORTED THAT DURING THE MASTECTOMY PROCEDURE, THE LIGASURE HAD AN INSUFFICIENT SEALING/ONLY PART, ALTHOUGH ENERGY OUTPUT AND SEALING COMPLETION SOUND WERE CONFIRMED. A SEAL ERROR OCCURRED FREQUENTLY. THE JAW REGION WAS IN A CLEAN CONDITION AND WAS CLEANED EVERY TIME IT GOT DIRTY. THE DEVICE WAS PLUGGED INTO A GENERATOR AT THE TIME OF THE EVENT, AND ANOTHER LIGASURE DEVICE WAS USED SUCCESSFULLY WITH THE SAME GENERATOR. THE ISSUE OCCURRED WHILE SEALING A TISSUE BUNDLE THAT WAS APPROXIMATELY 1 MM THICK. THERE WAS NO BLEEDING. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24754586 ↗MalfunctionMar 31, 2026Energy Output Problem; Intermittent Energy Output
IT WAS REPORTED THAT DURING A THYROIDECTOMY PROCEDURE INVOLVING THE DEVICE, AN ENERGY ACTIVATION ISSUE AND A SEALING ISSUE OCCURRED. AFTER THE DEVICE WAS CONNECTED TO THE GENERATOR, IT INITIALLY PERFORMED TWO SUCCESSFUL ACTIVATIONS. ON THE THIRD ACTIVATION, THE GENERATOR EMITTED THE SEALING SOUND AND FINAL TONE, BUT UPON OPENING THE CLAMP, THE TISSUE WAS NOT CLOTTED. IT WAS USED ON A NORMAL THICKNESS TISSUE AND THERE WAS NO RE-GRASP ALERT. THE SAME PROBLEM OCCURRED ON A SUBSEQUENT ATTEMPT. THE SURGICAL TEAM THEN SWITCHED TO A DIFFERENT DEVICE FROM THE SAME BATCH, WHICH FUNCTIONED CORRECTLY FOR THE REMAINDER OF THE SURGERY. THERE WAS NO BLEEDING AND THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24743076 ↗
FDA clearance and classification
Cleared through 510(k) K202917 on Mar 23, 2021 (decision: Substantially Equivalent). Submitted by Covidien, LLC as “LigaSure Exact Dissector, Nano-coated”. The FDA review took 175 days. FDA record ↗
Cleared through 510(k) K173281 on Mar 2, 2018 (decision: Substantially Equivalent). Submitted by Covidien as “LigaSure Exact Dissector, Nano-coated”. The FDA review took 137 days. FDA record ↗
The FDA regulates product code GEI (electrosurgical, cutting & coagulation & accessories) under 21 CFR 878.4400 as a Class II device. 21 CFR 878.4400 ↗
Common questions about the LigaSure LF2019
Has the LigaSure LF2019 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10884521741096), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the LigaSure LF2019?
The FDA's MAUDE database lists 929 adverse event reports for this device, received between Mar 28, 2018 and Jun 26, 2026. In those reports, the most common specific device problems are “Detachment of Device or Device Component” (419), “Energy Output Problem” (282) and “Peeled/Delaminated” (201); the most common patient problems are “Hemorrhage/Blood Loss/Bleeding” (30), “Burn(s)” (14) and “Device Embedded In Tissue or Plaque” (11). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the LigaSure LF2019?
None of the reports are classified as deaths, 73 as injuries and 856 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the LigaSure LF2019 FDA approved?
It was cleared through 510(k) K173281 on Mar 2, 2018; its record lists 2 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the LigaSure LF2019, and is it still sold?
The FDA's device database lists Covidien LP as the company responsible for it (brand LigaSure, model LF2019). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Electrosurgical, cutting & coagulation & accessories devices
- Vasoview Hemopro 2 VH-4000Maquet Cardiovascular LLC · Electrosurgical, Cutting & Coagulation & Accessories6 recalls1 death3,137 reports
- LigaSure LF1937Covidien LP · Electrosurgical, cutting & coagulation & accessories3 deaths2,038 reports
- Olympus WB91051WOLYMPUS Winter & Ibe GmbH · Electrosurgical, Cutting & Coagulation & Accessories1 death1,891 reports
- Valleylab FT10 VLFT10GENCovidien LP · Electrosurgical, cutting & coagulation & accessories1 recall5 deaths1,046 reports
- LigaSure LF1837Covidien LP · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES1 recall957 reports
- VAPR 225028Depuy Mitek, LLC · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES874 reports
- LigaSure LF1923Covidien LP · Electrosurgical, cutting & coagulation & accessories831 reports
- Vasoview Hemopro VH-3500Maquet Cardiovascular LLC · Electrosurgical, Cutting & Coagulation & Accessories4 recalls618 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page