SPEEDTRAP 223747Recalls & reported problems

Medos International Sàrl · SPEEDTRAP Graft Preparation System WHITE 30 mm · Class 2 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
9
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 10886705027149), received between Jun 4, 2018 and Jan 14, 2025 — classified as 9 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 2 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Detachment of Device or Device Component2
  • Appropriate Device Problem Term/Code Not Available1
  • Crack1
  • Device-Device Incompatibility1
  • Loosening of Implant Not Related to Bone-Ingrowth1
  • Migration or Expulsion of Device1
  • Positioning Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7
  • No Consequences Or Impact To Patient2

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 14, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE BEFORE TIGHTENING THE SPEEDTRAP WHITE 30MM DEVICE THE SUTURE DETACHED BEFORE TIGHTENING. THE PROCEDURE WAS COMPLETE SUCCESSFULLY. THERE WAS NO DELAY IN THE PROCEDURE REPORTED. NO FRAGMENTS WERE GENERATED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. THE DATE OF EVENT WAS UNKNOWN BUT WAS KNOWN TO HAVE OCCURRED IN 2024. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21152088 ↗
  • MalfunctionJan 10, 2025Use of Device Problem; Device-Device Incompatibility; Use of Device Problem; Device-Device Incompatibility

    IT WAS REPORTED THAT DURING AN ANTERIOR CRUCIATE LIGAMENT PROCEDURE, THE SPEEDTRAP WHITE 30MM DEVICE COULD NOT BE PULLED OUT AND ATTACHED TO THE GRAFT AFTER A FEW TRIES BY THE SURGEON. ANOTHER DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO DELAY IN THE PROCEDURE REPORTED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21123433 ↗
  • MalfunctionMay 22, 2024Unintended Movement; Unintended Movement

    IT WAS REPORTED THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE THE SPEEDTRAP WHITE 30MM SUTURE LOOSENED PRIOR TO USE. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO DELAY IN THE PROCEDURE REPORTED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19369239 ↗
  • MalfunctionJan 18, 2024Break; Break

    IT WAS REPORTED BY THE SALES REP IN CHINA THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE ON (B)(6) 2024, IT WAS OBSERVED THAT THE SPEEDTRAP CONSTRUCT WHITE, 30MM DEVICE SUTURE WAS BROKEN OFF. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18533692 ↗
  • MalfunctionApr 18, 2023Break; Appropriate Device Problem Term/Code Not Available; Break; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED BY THE SALES REP IN HONG KONG THAT DURING AN UNKNOWN PROCEDURE ON (B)(6) 2023, IT WAS OBSERVED THAT THE SPEEDTRAP CONSTRUCT  WHITE, LONG DEVICE WAS DAMAGED AT THE END OF THE GRAFT THAT CAUSED THE GRAFT TO BREAK. DURING IN-HOUSE ENGINEERING EVALUATION, IT WAS DETERMINED THAT THE WINDING WHITE SUTURE ON THE DEVICE WAS FRAYED AND BROKEN. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16763312 ↗
  • MalfunctionSep 27, 2022Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED BY THE SALES REP IN HONG KONG THAT DURING AN ACL (ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION) PROCEDURE ON (B)(6) 2022, IT WAS OBSERVED THAT THE SPEEDTRAP CONSTRUCT  WHITE, LONG DEVICE FAILED TO COMPRESS ONTO THE GRAFT; AND THEREFORE, FELL OFF FROM THE GRAFT. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15495024 ↗
  • MalfunctionJun 21, 2021Crack; Crack

    IT WAS REPORTED BY THE AFFILIATE IN (B)(6) THAT DURING AN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION PROCEDURE ON (B)(6) 2021, IT WAS OBSERVED THAT THE SPEEDTRAP WHITE 20MM SUTURE DEVICE SNAPPED AS IT WAS STRETCHED FROM THE FIXATION AT THE FEMORAL SIDE TO THE TIBIAL SIDE. THE SNAPPED GRAFTS WERE THEN SHORTENED BUT WAS USED TO COMPLETE THE FIXATION. THE PROCEDURE WAS COMPLETED WITH LESS THAN 30-MINUTE SURGICAL DELAY. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12033720 ↗
  • MalfunctionJan 22, 2020Positioning Failure; Positioning Failure

    IT WAS REPORTED BY THE AFFILIATE THAT DURING AN UNKNOWN PROCEDURE THE SPEEDTRAP WHITE 30MM FAILED TO DEPLOY. ADDITIONAL INFORMATION COULD NOT BE PROVIDED REGARDING THE EVENT OUTCOME, PATIENT STATUS, OR IF THE DEVICE WILL BE RETURNED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9619427 ↗
  • MalfunctionJun 4, 2018Migration or Expulsion of Device; Loosening of Implant Not Related to Bone-Ingrowth; Migration or Expulsion of Device; Loosening of Implant Not Related to Bone-Ingrowth

    IT WAS REPORTED BY OUR AFFILIATE THAT THE REPORTED PRODUCT WAS USED FOR THE ACL RECONSTRUCTION BY TENSIONING TO THE SEMITENDINOSUS MUSCLE ON (B)(6) 2018. IT WAS REPORTED THAT THE SUTURE WAS DETACHED WHEN THE ADJUSTABLE SUTURE WAS INSERTED TO THE BONE HOLE. THE ADJUSTABLE SUTURE COULD NOT APPLY ENOUGH TENSION TO THE SEMITENDINOSUS MUSCLE. THE SURGERY WAS COMPLETED BY INSERTING THE ANCHOR TO OPPOSITE SIDE OF THE GRAFT. IT WAS BRAND NEW AND THE FIRST USE WHEN THE ISSUE OCCURRED. THERE WAS LESS THAN 30 MIN. SURGICAL DELAY AND NO HARM TO THE PATIENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7566941 ↗

Other SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE devices

All SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page