Skip to content

SABERX .014 PTA Dilatation Catheter 47540150MRecalls & reported problems

Cordis US Corp. · PTA, RX, 4.0 x 150, 150cm · Class 2

All models of SABERX .014 PTA Dilatation Catheter (16)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20705032087169), received between Jan 9, 2026 and Jan 9, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Material Rupture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Rupture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 9, 2026Material Rupture

    AS REPORTED, A 4 MM X 15 CM SABERX .014 150 CM PTA BALLOON CATHETER RUPTURED DURING INFLATION AFTER EXCEEDING NOMINAL PRESSURE. AFTER THE BALLOON RUPTURE, DILATION WAS PERFORMED WITH A NEW UNKNOWN 4 MM X 4 CM BALLOON, FOLLOWED BY AN UNKNOWN DRUG-COATED BALLOON, AND THE PROCEDURE WAS COMPLETED. THERE WAS NO REPORTED PATIENT INJURY. THE PROCEDURE INVOLVED TREATMENT OF LEFT SUPERFICIAL FEMORAL ARTERY (SFA) TO BELOW-KNEE ARTERY (BKA) STENOSIS VIA RIGHT GROIN ACCESS, INSERTION OF AN UNKNOWN 6F GUIDING SHEATH, LESION CROSSING WITH AN UNKNOWN 0.014 GUIDEWIRE, AND PRE-DILATION USING AN UNKNOWN 1.25 MM X 1.5 CM BALLOON FOLLOWED BY AN UNKNOWN 3 MM X 4 CM BALLOON. IT WAS UNCLEAR WHETHER THE CAUSE OF THE BALLOON RUPTURE WAS LESION CALCIFICATION OR PRODUCT QUALITY. THE PRODUCT WAS STORED PROPERLY PER THE INSTRUCTIONS FOR USE (IFU) AND THERE WERE NO DIFFICULTIES REMOVING IT FROM THE HOOP, THE PROTECTIVE BALLOON COVER, THE STYLET, OR ANY STERILE PACKAGING COMPONENTS. NO KINKS OR DAMAGES WERE NOTED PRIOR TO INSERTION. THE DEVICE WAS PREPPED ACCORDING TO THE IFU AND MAINTAINED NEGATIVE PRESSURE NORMALLY. THE INTENDED PROCEDURE WAS PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) USING A CONTRALATERAL AP

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24026126 ↗

Other Catheter, angioplasty, peripheral, transluminal devices

All Catheter, angioplasty, peripheral, transluminal devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page