Terumo Advanced Perfusion System 1Recalls & reported problems across all models

Terumo Cardiovascular Systems Corporation · 31 models in the FDA device registry

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1,869
Deaths reported
2
Injuries reported
1
Recalls
11

We found 31 models of Terumo Advanced Perfusion System 1 by Terumo Cardiovascular Systems Corporation in the FDA's device registry (GUDID). Together they are named in 1,869 adverse event reports in the FDA's MAUDE database, received between May 18, 2018 and Sep 29, 2026 — classified as 2 deaths, 1 injury, 1,866 malfunctions.

The most frequently reported specific device problem is “Output Problem” (509 reports).

11 FDA recall records name at least one of these models by its device identifier.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works

Reports received per month, all models

Nov 2023: 26 reportsDec 2023: 11 reportsJan 2024: 26 reportsFeb 2024: 6 reportsMar 2024: 23 reportsApr 2024: 18 reportsMay 2024: 18 reportsJun 2024: 20 reportsJul 2024: 20 reportsAug 2024: 18 reportsSep 2024: 22 reportsOct 2024: 27 reportsNov 2024: 9 reportsDec 2024: 9 reportsJan 2025: 13 reportsFeb 2025: 17 reportsMar 2025: 26 reportsApr 2025: 17 reportsMay 2025: 34 reportsJun 2025: 17 reportsJul 2025: 23 reportsAug 2025: 28 reportsSep 2025: 12 reportsOct 2025: 16 reportsNov 2025: 29 reportsDec 2025: 25 reportsJan 2026: 11 reportsFeb 2026: 10 reportsMar 2026: 24 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 5 reportsSep 2026: 12 reportsOct 2026: 0 reports20242025202634
Last 36 months. The most recent month may be incomplete.

Terumo Advanced Perfusion System 1 recalls

FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.

  1. Jun 8, 2021Terminated

    intermittent failure causes a blender initialization fault upon start-up, or during an EPGS calibration attempt following the 15-minute warm-up period. The control sliders on the Central Control Monitor (CCM) are disabled and the gas system can only be controlled by the local control knobs

    Z-2350-2021 · Root cause: Nonconforming Material/Component · Recall details · FDA record ↗

  2. Aug 25, 2020Terminated

    Internal testing at the supplier, revealed that a crimped wire was placed into an air bubble detector (ABD) sensor connector backwards, preventing the crimped wire from locking into the mating wire connector. This intermittent connection may result in false air bubble alarms.

    Z-2961-2020 · Root cause: Employee error · Recall details · FDA record ↗

  3. Aug 25, 2020Terminated

    Internal testing at the supplier, revealed that a crimped wire was placed into an air bubble detector (ABD) sensor connector backwards, preventing the crimped wire from locking into the mating wire connector. This intermittent connection may result in false air bubble alarms.

    Z-2960-2020 · Root cause: Employee error · Recall details · FDA record ↗

  4. Aug 25, 2020Terminated

    Internal testing at the supplier, revealed that a crimped wire was placed into an air bubble detector (ABD) sensor connector backwards, preventing the crimped wire from locking into the mating wire connector. This intermittent connection may result in false air bubble alarms.

    Z-2959-2020 · Root cause: Employee error · Recall details · FDA record ↗

  5. Jan 10, 2020Terminated

    These roller pumps were assembled with pump shafts that may fail at the location of the thread where a locknut is installed. The failure is associated with a noise that is atypical of roller pump operation. The noise is caused when an unsecured shaft end contacts the rotating pulley of the roller pump. Prolonged use of a roller pump in this condition could lead to an eventual pump stop, resulting in the inability to create pump flow due to pulley loosening and drive belt damage.

    Z-1109-2020 · Root cause: Nonconforming Material/Component · Recall details · FDA record ↗

  6. Jan 10, 2020Terminated

    These roller pumps were assembled with pump shafts that may fail at the location of the thread where a locknut is installed. The failure is associated with a noise that is atypical of roller pump operation. The noise is caused when an unsecured shaft end contacts the rotating pulley of the roller pump. Prolonged use of a roller pump in this condition could lead to an eventual pump stop, resulting in the inability to create pump flow due to pulley loosening and drive belt damage.

    Z-1108-2020 · Root cause: Nonconforming Material/Component · Recall details · FDA record ↗

  7. Oct 17, 2018Terminated

    An intermittent failure which causes a blender initialization fault upon start-up or during an EPGS calibration attempt leads to the Central Control Monitor control sliders being disabled, such that the gas system can only be controlled by the local control knobs.

    Z-1769-2019 · Root cause: Process control · Recall details · FDA record ↗

  8. Sep 13, 2018Terminated

    The service manual was not updated at the time of the release of software version 1.30.

    Z-0176-2019 · Root cause: Error in labeling · Recall details · FDA record ↗

  9. Jan 19, 2018Terminated

    Inaccurrate flow readings. Depending on the degree of inaccuracy, this issue may not be easy for the user to detect during setup or use (for example, following a Flow Probe relocation or manipulation).

    Z-1478-2018 · Root cause: Employee error · Recall details · FDA record ↗

  10. Feb 20, 2017Terminated

    Terumo CVS initiated a voluntary recall for the Level Sensor II Pads and Level Sensor Gel Pads due to non-compliant labeling because the product expiration date is displayed in a format that may not be recognizable to all users.

    Z-1459-2017 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

  11. Feb 20, 2017Terminated

    Terumo CVS initiated a voluntary recall for the Level Sensor II Pads and Level Sensor Gel Pads due to non-compliant labeling because the product expiration date is displayed in a format that may not be recognizable to all users.

    Z-1458-2017 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

Most reported Terumo Advanced Perfusion System 1 problems

Device problems

  • Output Problem509
  • Display or Visual Feedback Problem197
  • Device Alarm System165
  • Calibration Problem120
  • Incorrect, Inadequate or Imprecise Result or Readings116
  • Mechanical Problem111
  • Failure to Calibrate88
  • Charging Problem72

Patient problems

  • No Clinical Signs, Symptoms or Conditions1,259
  • No Consequences Or Impact To Patient345
  • No Patient Involvement214
  • Insufficient Information139
  • No Known Impact Or Consequence To Patient55
  • Death2
  • Blood Loss1

Terumo Advanced Perfusion System 1 models

31 models, most reported first. Each model has its own page with its reports, recalls and device details.

Recent Terumo Advanced Perfusion System 1 adverse event reports

The 15 most recent reports across all models, in the reporter's own words as published by the FDA.