Skip to content

Medline Industries, Inc. recallZ-2304-2023 · MEDLINE INDUSTRIES, LP - Northfield · initiated May 15, 2023

Open, Classified

Is my device affected?

  1. Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
  2. If yours is listed, follow the instructions from MEDLINE INDUSTRIES, LP - Northfield or your healthcare provider. The company's action is summarized under what the company is doing.
  3. Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.

Where to find your model and lot numbers · What recall classes and statuses mean

Why it was recalled

Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.

FDA root cause category: Nonconforming Material/Component

What the company is doing

Medline notified customers beginning on 05/15/2023, via mail and email with letter. Customers with Medline Probe Cover Kits were instructed to check inventory for affected kits, destroy any affected kits, and complete and return the response form. Distributors were instructed to notify their customers and have them document and destroy affected kits. Customers with the non-sterile and sterile procedural kits were instructed to quarantine kits, complete and return the response form and, once updated labels are received, over label and discard the affected ultrasound gel product within the kits. Distributors were instructed to notify customers of the recall and have customers return any affected product for return to Medline. Medline identified additional units of Medline Probe Cover Kits and notified customers on 06/22/2023. Customers were instructed to quarantine kits, complete and return the response form and, once updated labels are received, over label and discard the affected ultrasound gel product within the kits.

Recall details

Recall number
Z-2304-2023
Status
Open, Classified
Initiated by the company
May 15, 2023
Posted by the FDA
Aug 3, 2023
Recalling firm
MEDLINE INDUSTRIES, LP - Northfield
Quantity
1,218 kits
Product code
OFD
Distribution
Worldwide distribution - US Nationwide and the countries of Canada, China, Costa Rica, India, Lebanon, Panama, Qatar, Saudi Arabia, Singapore, United Arab Emirates.

Product description

Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. 16CM CENTRAL LINE BUNDLE, Model Number: STCVC2020; b. ARTERIAL LINE TRAY, Model Number: ART905; c. CATHETERLESS INSERTION KIT, Model Number: CVI4510; d. OR CATHETER INSERTION SETUP PACK, Model Number: ECVC7165A; e. VANTEX 7FR 3L 16CM CVC BUNDLE, Model Number: STCVC01145B; f. VANTEX TRIPLE LUMEN BUNDLE, Model Number: STCVC2000;

Code information (models, lots, serial numbers)

All lot numbers for the following models and corresponding UPCs distributed from Medline between 04/01/2020 and 04/28/2023: a. Model Number: STCVC2020, UPC Number: 10653160338765. b. Model Number: ART905, UPC Number: 10653160326557. c. Model Number: CVI4510, UPC Number: 10653160321194. d. Model Number: ECVC7165A, UPC Number: 10653160346760. e. Model Number: STCVC01145B, UPC Number: 10653160351924. f. Model Number: STCVC2000, UPC Number: 10653160336792.

Devices named in this recall

6 devices in the FDA device registry whose identifier appears in the recall's code information.

Product lines

Other products in the same recall event

The FDA groups related products into one recall event (event 92399).

Sources and updates

How recalls are matched to devices · Editorial policy · Report an error on this page