Medical device recalls: January 2016
The FDA posted 118 medical device recall records in January 2016, from 53 recall events by 50 companies. 7 are Class I, the most serious category.
Each product in a recall gets its own record, so one recall event can cover several records. What recall classes mean.
Companies with the most recall events
- Boston Scientific Corporation · 2 events, 3 records
- Cyberonics, Inc · 2 events, 2 records
- Stryker Sustainability Solutions · 2 events, 2 records, 1 Class I
- Philips Electronics North America Corporation · 1 event, 29 records
- Siemens Healthcare Diagnostics Inc · 1 event, 11 records
- Perkinelmer · 1 event, 7 records
- GE Medical Systems, LLC · 1 event, 6 records
- Biomet 3i, LLC · 1 event, 4 records
FDA root cause
- Device Design · 40
- Nonconforming Material/Component · 17
- Labeling design · 11
- Process control · 10
- Software design · 8
- Under Investigation by firm · 7
- Process design · 5
- Component design/selection · 5
Class I recalls (7)
The most serious: a reasonable probability that using the device will cause serious health problems or death.
- Z-0660-2016 · St Jude Medical Cardiac Rhythm Management Division · posted Jan 21, 2016 · Terminated
Leads may have been compromised during the manufacturing process, with cuts in the insulation layer of the SVC shock coil.
- Z-0598-2016 · Brainlab AG · posted Jan 19, 2016 · Terminated
Software Error: The effect of setup on overall navigation accuracy could potentially intensify small inaccuracies arising from individual steps of a complex navigation procedure that may cause an inaccurate display of instruments by the navigation system…
- arkray SPOTCHEM II Glucose Reagent test strips, Item No. 77101, MEDTEST DX Catalog # 77424. ↗Class IZ-0630-2016 · Arkray Factory USA, Inc. · posted Jan 15, 2016 · Terminated
One lot each of SPOTCHEM II Basic PANEL-1 Reagent Test Strip and SPOTCHEM II Glucose Reagent Test Strip are being recalled due to a lowered reaction rate in the reagent pad for glucose. The affected lots will display a result of approximately 300 to 400…
- Z-0631-2016 · Arkray Factory USA, Inc. · posted Jan 15, 2016 · Terminated
One lot each of SPOTCHEM II Basic PANEL-1 Reagent Test Strip and SPOTCHEM II Glucose Reagent Test Strip are being recalled due to a lowered reaction rate in the reagent pad for glucose. The affected lots will display a result of approximately 300 to 400…
- Z-0586-2016 · Thornhill Research Inc · posted Jan 11, 2016 · Terminated
Batteries found unresponsive after storage, not recognized by main device, and are perpetually enabled.
- Z-0587-2016 · Thornhill Research Inc · posted Jan 11, 2016 · Terminated
Batteries found unresponsive after storage, not recognized by main device, and are perpetually enabled.
- Z-0478-2016 · Stryker Sustainability Solutions · posted Jan 4, 2016 · Terminated
Stryker Sustainability Solutions is recalling the Fuhrman Pleural & Pneumopericardial Drainage Set due to receiving complaints that it broke off in the pleural cavity while inserting the device into the patient.
Class II recalls (110)
The device may cause temporary or medically reversible health problems, or the chance of serious harm is remote.
- Z-0702-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Allura Xper FD10/10 ↗Class IIZ-0703-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Allura Xper FD10 OR Table ↗Class IIZ-0704-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Allura Xper FD20/10 ↗Class IIZ-0705-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Allura Xper FD20/15 ↗Class IIZ-0706-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Allura Xper FD20 ↗Class IIZ-0707-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- UNIQ FD ↗Class IIZ-0708-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- UNIQ FD OR table ↗Class IIZ-0709-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Allura Xper FD20 OR Table ↗Class IIZ-0710-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Allura Xper FD20 Biplane ↗Class IIZ-0711-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Z-0712-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Allura Xper FD20/20 ↗Class IIZ-0713-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Allura Xper FD20/20 OR Table ↗Class IIZ-0714-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Allura CV20 ↗Class IIZ-0715-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Cardiovascular Allura Centron ↗Class IIZ-0716-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- INTEGRIS H3000 ↗Class IIZ-0717-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- INTEGRIS HM3000 ↗Class IIZ-0718-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- INTEGRIS BN/BV3000 ↗Class IIZ-0719-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- INTEGRIS BH3000 ↗Class IIZ-0720-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- INTEGRIS V3000 ↗Class IIZ-0721-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- INTEGRIS H5000 ↗Class IIZ-0722-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- INTEGRIS BH5000 ↗Class IIZ-0723-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Z-0724-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Z-0725-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- INTEGRIS Allura 9 (biplane) ↗Class IIZ-0726-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- INTEGRIS Allura 15-12 (mono) ↗Class IIZ-0727-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Z-0728-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- INTEGRIS CV ↗Class IIZ-0729-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- INTEGRIS BV3000 MONO ↗Class IIZ-0730-2016 · Philips Electronics North America Corporation · posted Jan 30, 2016 · Terminated
The use of Allura Xper, Allura Clarity, Allura CV, Allura Centron and UNIQ systems regarding live images and still images can lead to still images being interpreted as live Images.
- Z-0731-2016 · Baxter Corporation Englewood · posted Jan 30, 2016 · Terminated
All lots of RAPIDFILL Syringe Strips lack evidence supporting the packaging claim for 12-month shelf life on released product.
- PS-500 Scope Warmer ↗Class IIZ-0732-2016 · JosNoe Medical, Inc. · posted Jan 30, 2016 · Terminated
Damage to package seals potentially compromising sterility.
- Z-0733-2016 · Owens & Minor Distribution, Inc. · posted Jan 30, 2016 · Terminated
MediChoice sterile cohesive bandages imported and sold under a private brand by Owens & Minor were tested and found to have microbial contamination.
- Z-0734-2016 · Owens & Minor Distribution, Inc. · posted Jan 30, 2016 · Terminated
MediChoice sterile cohesive bandages imported and sold under a private brand by Owens & Minor were tested and found to have microbial contamination.
- Z-0735-2016 · Owens & Minor Distribution, Inc. · posted Jan 30, 2016 · Terminated
MediChoice sterile cohesive bandages imported and sold under a private brand by Owens & Minor were tested and found to have microbial contamination.
- Z-0699-2016 · Smith & Nephew, Inc., Endoscopy Div. · posted Jan 29, 2016 · Terminated
Driver does not meet specification, oversized. Driver may not be able to be fully inserted into the screw, or screw may become stuck on the driver.
- Z-0700-2016 · Smith & Nephew, Inc., Endoscopy Div. · posted Jan 29, 2016 · Terminated
Driver does not meet specification, oversized. Driver may not be able to be fully inserted into the screw, or screw may become stuck on the driver.
- Z-0701-2016 · Mindray DS USA, Inc. dba Mindray North America · posted Jan 29, 2016 · Terminated
An issue with the Panorama Central Station may cause the system to spontaneously restart. This may occur after about 49 days of continuous operation. On restart, monitoring will be lost for about 2.5 minutes. Settings and configurations are maintained.
- Z-0697-2016 · Phadia Ab · posted Jan 28, 2016 · Terminated
All equivocal and positive results (greater or equal 7 EliA U/ml) on EliA SmDP well lot 0018 may be incorrect and must be considered invalid. Patient samples in complaint investigations caused unspecific signals up to 22 U/ml on EliA SmDP well lot 0018.…
- Z-0693-2016 · Fresenius Medical Care Renal Therapies Group, LLC · posted Jan 27, 2016 · Terminated
The door latch may not fully close and the door may open unexpectedly. The door may make physical contact with anything near the door of the machine, including the patient. May cause injury, delay in treatment, or Increased Intraperitoneal Volume (IIPV)…
- Fuse 1C Colonoscope ↗Class IIZ-0694-2016 · EndoChoice, Inc. · posted Jan 27, 2016 · Terminated
The bending section of the device may partially separate from the insertion tube. Potential for tissue trauma.
- D-10 Rack Loader ↗Class IIZ-0695-2016 · Bio-Rad Laboratories, Inc. · posted Jan 27, 2016 · Terminated
On a rare occasion, there is a potential to assign a patient result to an incorrect sample ID when running in D10 Rack Loader configuration.
- Z-0690-2016 · Globalmed Logistix · posted Jan 25, 2016 · Terminated
The cannulae may bend during procedure.
- Z-0689-2016 · Cook Medical Incorporated · posted Jan 22, 2016 · Terminated
Manufacturing of the joint between the inner catheter and stylet of the delivery system does not consistently meet specifications, and the joint may separate during deployment. Failure of this joint during a procedure may result in a partial stent…
- Z-0674-2016 · Valeant Pharmacueticals International · posted Jan 21, 2016 · Terminated
The Serial I.D. Label and some information in the Operation Manual for the SPAG 2 6000 series is incorrect or out of date, including references to accessories that are no longer available.
- Z-0675-2016 · Rymed Technologies, LLC · posted Jan 21, 2016 · Terminated
Potential for the female luer component of the InVision-Plus IV connector to crack during use.
- InVision-Plus CS Needleless IV Connector, Catalog Number RYM-7001. Disposable, Single Use. ↗Class IIZ-0676-2016 · Rymed Technologies, LLC · posted Jan 21, 2016 · Terminated
Potential for the female luer component of the InVision-Plus IV connector to crack during use.
- Z-0677-2016 · GE Medical Systems, LLC · posted Jan 21, 2016 · Terminated
The Drive Gas Check Valve of certain Anesthesia products could become stuck in a fixed open position, which could cause pressure to build in the mechanical ventilation cycle. If this issue is left unresolved, it could result in excessive or prolonged…
- Z-0678-2016 · GE Medical Systems, LLC · posted Jan 21, 2016 · Terminated
The Drive Gas Check Valve of certain Anesthesia products could become stuck in a fixed open position, which could cause pressure to build in the mechanical ventilation cycle. If this issue is left unresolved, it could result in excessive or prolonged…
- Z-0679-2016 · GE Medical Systems, LLC · posted Jan 21, 2016 · Terminated
The Drive Gas Check Valve of certain Anesthesia products could become stuck in a fixed open position, which could cause pressure to build in the mechanical ventilation cycle. If this issue is left unresolved, it could result in excessive or prolonged…
- Z-0680-2016 · GE Medical Systems, LLC · posted Jan 21, 2016 · Terminated
The Drive Gas Check Valve of certain Anesthesia products could become stuck in a fixed open position, which could cause pressure to build in the mechanical ventilation cycle. If this issue is left unresolved, it could result in excessive or prolonged…
- Z-0681-2016 · GE Medical Systems, LLC · posted Jan 21, 2016 · Terminated
The Drive Gas Check Valve of certain Anesthesia products could become stuck in a fixed open position, which could cause pressure to build in the mechanical ventilation cycle. If this issue is left unresolved, it could result in excessive or prolonged…
- Z-0682-2016 · GE Medical Systems, LLC · posted Jan 21, 2016 · Terminated
The Drive Gas Check Valve of certain Anesthesia products could become stuck in a fixed open position, which could cause pressure to build in the mechanical ventilation cycle. If this issue is left unresolved, it could result in excessive or prolonged…
- Z-0683-2016 · Iba Dosimetry Gmbh · posted Jan 21, 2016 · Terminated
When the electric lift table is connected to the mains power, in a very rare occasion, the table may start to move up in an uncontrolled manner.
- Z-0687-2016 · Siemens Medical Solutions USA, Inc. · posted Jan 21, 2016 · Terminated
To provide operator instruction manuals for the e.cam Dual Signature; Gamma Camera that were not sent in its entirety when the e.cam systems were refurbished and shipped to the customer.
- Z-0662-2016 · Innovasis, Inc · posted Jan 19, 2016 · Terminated
Innovasis recalled two lots of Excella II titanium rods which were packaged using each other's labels.
- Z-0661-2016 · Fukuda Denshi USA, Inc. · posted Jan 16, 2016 · Terminated
A possible malfunction where a Short-term Battery Error message has appeared and has been traced back to a bad (damaged) Lithium-Ion capacitor (Short-term Backup battery).
- Z-0656-2016 · DePuy Mitek, Inc., a Johnson & Johnson Co. · posted Jan 15, 2016 · Terminated
Product is incorrectly labeled. The blade configuration in the affected lots does not match the description on the label.
- Z-0657-2016 · DePuy Mitek, Inc., a Johnson & Johnson Co. · posted Jan 15, 2016 · Terminated
Product is incorrectly labeled. The blade configuration in the affected lots does not match the description on the label.
- Z-0658-2016 · DePuy Mitek, Inc., a Johnson & Johnson Co. · posted Jan 15, 2016 · Terminated
Product is incorrectly labeled. The blade configuration in the affected lots does not match the description on the label.
- Z-0659-2016 · Cyberonics, Inc · posted Jan 15, 2016 · Terminated
Recall being initiated in response to three reports of "Burst Watchdog Timeout" events occurring with the Model 106 AspireSR Generator, resulting in a device reset condition where stimulation output is disabled.
- 0 deg, 8mm Endoscope, IS4000: ↗Class IIZ-0652-2016 · Intuitive Surgical, Inc. · posted Jan 14, 2016 · Terminated
This correction to the da Vinci Xi I&A User Manual communicates proper use of the da Vinci Xi 8 mm Endoscopes in combination with the da Vinci 8 mm and 12 mm cannulae, cannula reducers, and monopolar energy instruments. It informs customers of scenarios…
- 30 deg, 8mm Endoscope, IS4000: ↗Class IIZ-0653-2016 · Intuitive Surgical, Inc. · posted Jan 14, 2016 · Terminated
This correction to the da Vinci Xi I&A User Manual communicates proper use of the da Vinci Xi 8 mm Endoscopes in combination with the da Vinci 8 mm and 12 mm cannulae, cannula reducers, and monopolar energy instruments. It informs customers of scenarios…
- Z-0655-2016 · Skytron, Div. The KMW Group, Inc · posted Jan 14, 2016 · Terminated
The hardware that holds the VESA plate and the display interface / monitor to the bracket may fail causing the display interface to fall from the bracket. Over time and with use the threaded rod hardware material can weaken and detach from the bracket. A…
- Z-0640-2016 · Ortho-Clinical Diagnostics · posted Jan 13, 2016 · Terminated
Software anomaly may allow VITROS Systems to sample and process assays while the fluids and reagent temperatures are not in the required temperature range for optimal processing. When this intermittent issue occurs, the VITROS Systems continue to operate…
- Z-0641-2016 · Ortho-Clinical Diagnostics · posted Jan 13, 2016 · Terminated
Software anomaly may allow VITROS Systems to sample and process assays while the fluids and reagent temperatures are not in the required temperature range for optimal processing. When this intermittent issue occurs, the VITROS Systems continue to operate…
- Z-0642-2016 · Ortho-Clinical Diagnostics · posted Jan 13, 2016 · Terminated
Software anomaly may allow VITROS Systems to sample and process assays while the fluids and reagent temperatures are not in the required temperature range for optimal processing. When this intermittent issue occurs, the VITROS Systems continue to operate…
- Z-0643-2016 · Ortho-Clinical Diagnostics · posted Jan 13, 2016 · Terminated
Software anomaly may allow VITROS Systems to sample and process assays while the fluids and reagent temperatures are not in the required temperature range for optimal processing. When this intermittent issue occurs, the VITROS Systems continue to operate…
- Z-0644-2016 · CompView Medical, LLC · posted Jan 13, 2016 · Terminated
The attachment of the NuCART Spring Arm to the NuCART horizontal boom may come apart if the securing ring (snap ring) was not installed correctly causing the spring arm to release and detach.
- Z-0645-2016 · Cyberonics, Inc · posted Jan 13, 2016 · Terminated
Certain Model 106 Pulse Generators demonstrate delays in sensing during use of the 'Verify Heartbeat Detection' feature and exhibit the potential for decreased battery longevity.
- Z-0650-2016 · Biomet, Inc. · posted Jan 13, 2016 · Terminated
PMMA is listed as a material on the label but the product does not contain PMMA.
- Z-0629-2016 · Stryker Sustainability Solutions · posted Jan 12, 2016 · Terminated
Reprocessed Stryker Pressure Tourniquet Cuffs were mislabeled, including some labeled as single port when they contained dual port, and vice versa.
- Z-0632-2016 · Perkinelmer · posted Jan 12, 2016 · Terminated
The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the…
- Z-0633-2016 · Perkinelmer · posted Jan 12, 2016 · Terminated
The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the…
- Z-0634-2016 · Perkinelmer · posted Jan 12, 2016 · Terminated
The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the…
- Z-0635-2016 · Perkinelmer · posted Jan 12, 2016 · Terminated
The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the…
- Z-0636-2016 · Perkinelmer · posted Jan 12, 2016 · Terminated
The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the…
- Z-0637-2016 · Perkinelmer · posted Jan 12, 2016 · Terminated
The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the…
- Z-0638-2016 · Perkinelmer · posted Jan 12, 2016 · Terminated
The content of the second #023 barcode ID label in the Barcode ID Label Binder is incorrect. The second barcode ID label #023 symbol incorrectly identifies as #024 when scanned. If measurement protocols have been programmed for both ID #023 and #024, the…
- Z-0627-2016 · Bayer Healthcare · posted Jan 11, 2016 · Terminated
The firm's investigation of the Medrad Intego indicates that the inner diameter of the saline tubing is out of specification and may result in the system failing to position the dose correctly during extraction, potentially leading to a low measurement of…
- Z-0626-2016 · Encore Medical, Lp · posted Jan 9, 2016 · Terminated
The trial shell mating feature on the broach is undersized.
- Z-0620-2016 · Boston Scientific Corporation · posted Jan 8, 2016 · Terminated
The literature packet packaged with the devices incorrectly describes the pacemaker as SR when it is actually a DR pacemaker or DR when it is actually a SR pacemaker.
- Z-0621-2016 · Boston Scientific Corporation · posted Jan 8, 2016 · Terminated
The literature packet packaged with the devices incorrectly describes the pacemaker as SR when it is actually a DR pacemaker or DR when it is actually a SR pacemaker.
- Z-0623-2016 · ArthroCare Corporation · posted Jan 8, 2016 · Terminated
There is cracking in the tray when the device is snapped into place. The crack is through the full thickness of the tray, compromising the sterile barrier.
- NIPRO SET / SLIMLINE BLOOD TUBING SET for Hemodialysis with Transducer Protectors and Priming Set ↗Class IIZ-0624-2016 · Nipro Medical Corporation · posted Jan 8, 2016 · Terminated
Blood foaming was found during evaluation of the product.
- Z-0609-2016 · Siemens Healthcare Diagnostics Inc · posted Jan 7, 2016 · Terminated
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
- Z-0610-2016 · Siemens Healthcare Diagnostics Inc · posted Jan 7, 2016 · Terminated
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
- Z-0611-2016 · Siemens Healthcare Diagnostics Inc · posted Jan 7, 2016 · Terminated
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
- Z-0612-2016 · Siemens Healthcare Diagnostics Inc · posted Jan 7, 2016 · Terminated
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
- Z-0613-2016 · Siemens Healthcare Diagnostics Inc · posted Jan 7, 2016 · Terminated
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
- Z-0614-2016 · Siemens Healthcare Diagnostics Inc · posted Jan 7, 2016 · Terminated
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
- Z-0615-2016 · Siemens Healthcare Diagnostics Inc · posted Jan 7, 2016 · Terminated
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
- Z-0616-2016 · Siemens Healthcare Diagnostics Inc · posted Jan 7, 2016 · Terminated
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
- Z-0617-2016 · Siemens Healthcare Diagnostics Inc · posted Jan 7, 2016 · Terminated
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
- Siemens Acute Care MYO DilPak ↗Class IIZ-0618-2016 · Siemens Healthcare Diagnostics Inc · posted Jan 7, 2016 · Terminated
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
- Z-0619-2016 · Siemens Healthcare Diagnostics Inc · posted Jan 7, 2016 · Terminated
Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
- Z-0591-2016 · Biomet 3i, LLC · posted Jan 6, 2016 · Terminated
Inadequate biocompatibility testing.
- Z-0592-2016 · Biomet 3i, LLC · posted Jan 6, 2016 · Terminated
Inadequate biocompatibility testing.
- Z-0593-2016 · Biomet 3i, LLC · posted Jan 6, 2016 · Terminated
Inadequate biocompatibility testing.
- Z-0594-2016 · Biomet 3i, LLC · posted Jan 6, 2016 · Terminated
Inadequate biocompatibility testing.
- Z-0596-2016 · Philips Ultrasound, Inc. · posted Jan 6, 2016 · Terminated
Color Flow direction is displayed incorrectly in Lumify 1.0. The system displayed Color Flow direction does not correctly represent the annotated Color Bar or Velocity Markers. (e.g.) When the Color Bar conveys that Red is to be displayed for color flow…
- Z-0597-2016 · Siemens Medical Solutions USA, Inc · posted Jan 6, 2016 · Terminated
Potential post-processing software issue when using tabcard "4D" on X-Workplace with software version VD10E. A too small measurement in the MPRs of a volume when images are acquired with a CT scanner with a tilted gantry. In a 2x2 layout, the 4D tabcard…
- Z-0600-2016 · Kci USA, Inc. · posted Jan 6, 2016 · Terminated
There is potential for small holes, the size of a pin, to develop in the pouches of the ActiV.A.C. Sterile Canisters.
- Z-0602-2016 · Ethicon, Inc. · posted Jan 6, 2016 · Terminated
Stability data does not substantiate the labeled two-year shelf life of affected product.
- SYNTHES ↗Class IIZ-0585-2016 · Synthes (USA) Products LLC · posted Jan 5, 2016 · Terminated
The 13.5mm Medullary Reamer head, lot #F-17180, is etched as dimension 13.5mm while the actual dimension is 14mm.
- Z-0588-2016 · Boston Scientific Corporation · posted Jan 5, 2016 · Terminated
Potential for separation of the proximal handle from the shaft.
- Z-0589-2016 · Maquet Cardiovascular Us Sales, Llc · posted Jan 5, 2016 · Terminated
Failure of the HEATER-COOLER UNIT (HCU 30) Type 2 power supply board. A drop of more than 10% voltage can cause overheating and subsequent failing of the R56 thermistor of the power supply board. Board failure typically occurs when the compressor is…
- Z-0590-2016 · Zimmer Manufacturing B.V. · posted Jan 5, 2016 · Terminated
A product complaint was received stating that a carton labeled as a Precoat Stemmed Tibia Size 3 was opened for use and the contents were a non-augmented Stemmed Tibia Plate size 3.
- Z-0572-2016 · Partners In Medicine Llc · posted Jan 4, 2016 · Terminated
Device non-conformity which may lead to an incorrect oscillometric measurement of upper arm blood pressure values in some subjects - mainly in tall and slim persons (overestimation of systolic blood pressure, underestimation of diastolic blood pressure).
- Z-0573-2016 · Smith & Nephew, Inc. · posted Jan 4, 2016 · Terminated
One lot of 35 mm patella implants is labeled as 32 mm. These implants have pegs which are spaced proportionally; therefore the mismatch prevents the pegs from properly aligning with pre-drilled holes during implantation.
- Z-0582-2016 · Vidco, Inc. · posted Jan 4, 2016 · Terminated
Testing at customer site showed unit Remote Patient Monitoring System MDP2040-0100 in a continuous trap condition, not allowing system to reset and reboot. Two customers recently complained of the system freezing and it could only be restarted if the user…
Class III recalls (1)
Using the device is not likely to cause health problems, but it violates FDA rules.
- Z-0628-2016 · Becton, Dickinson and Company, BD Biosciences · posted Jan 11, 2016 · Terminated
Becton, Dickinson and Company (BD) has determined that the FMC7 FITC (ASR) is exhibiting functional degradation. The functional degradation has the effect of reducing the percent positive from 100% down to approximately 87%.
Source: FDA Medical Device Recalls and FDA enforcement reports (recall class), via openFDA. Records are grouped by the date the FDA posted them. Methodology · Not medical advice.