AGENT™ H7493960815400Recalls & reported problems
Boston Scientific Corporation · Paclitaxel-Coated Balloon Catheter · Class 3
All models of AGENT (23)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00191506014773), received between May 5, 2025 and Aug 19, 2026 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
- Contamination1
- Difficult to Advance1
- Material Rupture1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 19, 2026Break; Difficult to Advance
It was reported that a shaft break occurred.The 90% stenosed target lesion was located in a moderately tortuous and severely calcified distal right coronary artery (RCA). A 4.00 mm x 15.00 mm Agent drug coated balloon (DCB) was selected for treatment. During the procedure, while the physician was advancing the balloon, it snapped at the mid shaft. The device was removed as a single unit, and the procedure was completed using a different device.It was further reported that the user encounter resistance while advancing the device. It was fractured on the balloon shaft. And there was no patient complications.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50334625 ↗MalfunctionMay 12, 2026Material Rupture
IT WAS REPORTED THAT A BALLOON RUPTURE OCCURRED. A 4.00 MM X 15.00 MM AGENT DRUG-COATED BALLOON (DCB) WAS SELECTED FOR A PERCUTANEOUS CORONARY INTERVENTION (PCI). DURING THE PROCEDURE, THE BALLOON RUPTURED. THE DEVICE WAS REMOVED AND THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25150240 ↗MalfunctionMay 5, 2025Contamination; Contamination
IT WAS REPORTED THAT CONTAMINATION OCCURRED. A 4.00 X 15MM AGENT DCB BALLOON WAS SELECTED FOR IN-STENT RESTENOSIS PERCUTANEOUS CORONARY INTERVENTION (ISR PCI) PROCEDURE. DURING PREPARATION, BALLOON BECAME CONTAMINATED ON THE FIELD AFTER OPENING. PROCEDURE WAS COMPLETED USING NEW AGENT DCB BALLOON AND NO PATIENT COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21959887 ↗
Other Drug-eluting percutaneous transluminal coronary angioplasty catheter devices
- AGENT™ H7493960830250Boston Scientific Corporation · Drug-eluting percutaneous transluminal coronary angioplasty catheter10 reports
- AGENT™ H7493960830300Boston Scientific Corporation · Drug-eluting percutaneous transluminal coronary angioplasty catheter8 reports
- AGENT™ H7493960820300Boston Scientific Corporation · Drug-eluting percutaneous transluminal coronary angioplasty catheter8 reports
- AGENT™ H7493960820250Boston Scientific Corporation · Drug-eluting percutaneous transluminal coronary angioplasty catheter6 reports
- AGENT™ H7493960830400Boston Scientific Corporation · Drug-eluting percutaneous transluminal coronary angioplasty catheter6 reports
- AGENT™ H7493960830350Boston Scientific Corporation · Drug-eluting percutaneous transluminal coronary angioplasty catheter5 reports
- AGENT™ H7493960820400Boston Scientific Corporation · Drug-eluting percutaneous transluminal coronary angioplasty catheter5 reports
- AGENT™ H7493960815300Boston Scientific Corporation · Drug-eluting percutaneous transluminal coronary angioplasty catheter5 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page