Dexcom G7 GSS (161) STP-AT-013Recalls & reported problems
Dexcom, Inc. · G7 US Medicare Sensor/Transmitter 1-pack · Class 2
All models of Dexcom G7 (32) · Dexcom G7 GSS (161) (4)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
Quick summary
This Dexcom G7 sensor and transmitter has 16,679 adverse event reports in the FDA database, including 386 injuries and no deaths. Reports mostly describe sensors coming off, signal loss, and low readings, and some list a detached part left in the body. Reports in the last 12 months (11,490) are far higher than in the 12 months before (5,054). No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 16,596
- Deaths reported
- 0
- Injuries reported
- 388
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 16,596 adverse event reports that list this exact device (DI 00386270004116), received between May 10, 2024 and Sep 23, 2026 — classified as 388 injuries, 16,208 malfunctions.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (6,370 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component6,370
- Wireless Communication Problem5,675
- Low Readings2,328
- Break876
- High Readings674
- Incorrect, Inadequate or Imprecise Result or Readings242
- Appropriate Device Problem Term/Code Not Available160
- Premature End-of-Life Indicator154
Patient problems
- No Clinical Signs, Symptoms or Conditions12,998
- Hyperglycemia2,397
- Hypoglycemia566
- Foreign Body In Patient491
- Loss of consciousness105
- Dizziness59
- Vomiting57
- Confusion/ Disorientation56
Recent adverse event reports
The 25 most recent of 16,596 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 23, 2026Wireless Communication Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50876241 ↗MalfunctionSep 23, 2026Break
It was reported that a broken sensor wire occurred. No product or data was provided for evaluation. The allegation and a probable cause could not be determined. No injury or medical intervention was reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50871667 ↗MalfunctionSep 23, 2026Wireless Communication Problem
It was reported that a signal loss occurred. No product or data was provided for evaluation. The allegation and a probable cause could not be determined. No injury or medical intervention was reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50871337 ↗MalfunctionSep 21, 2026Wireless Communication Problem
It was reported that a signal loss occurred. No product or data was provided for evaluation. The allegation and a probable cause could not be determined. No injury or medical intervention was reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50840290 ↗MalfunctionSep 15, 2026Wireless Communication Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50775799 ↗MalfunctionSep 14, 2026Wireless Communication Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50763505 ↗MalfunctionSep 11, 2026Wireless Communication Problem
It was reported that a pairing issue occurred. Performance data was reviewed. A pairing issue was not found within the investigation window. The allegation was not confirmed. However, signal loss over one hour was found in connection to the reported allegation. The probable cause of the signal loss could not be determined. No injury or medical intervention was reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50736731 ↗MalfunctionSep 11, 2026Wireless Communication Problem
It was reported that signal loss occurred. The product was evaluated. An external visual inspection was performed and passed. Nordic Bluetooth Pairing Test was performed and passed. Performance data was not provided for evaluation. The allegation could not be determined. A probable cause could not be determined as the allegation was not found. No injury or medical intervention was reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50725516 ↗MalfunctionSep 10, 2026Wireless Communication Problem
It was reported that signal loss occurred. Product was provided for investigation. An external visual inspection was performed and passed. Nordic Bluetooth Pairing Test was performed and passed. Performance data was reviewed. The allegation was confirmed due to the finding of signal loss over an hour within the investigation window. The probable cause could not be determined. No injury or medical intervention was reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50717207 ↗InjurySep 9, 2026Low Readings
It was reported that an inaccuracy between the Continuous Glucose Monitor (CGM) and the Blood Glucose (BG) meter occurred. On 08/09/2026, the patient experienced lethargy and increased urination. The patient was brought to the hospital and when a fingerstick was taken the CGM reading was LOW, and the blood glucose reading was 500 mg/dL. Ketones were high, but no specific value was reported. The patient experienced Diabetic Ketoacidosis and was treated with intravenous insulin and fluids. No further medication was reported and the patient was discharged after spending less than 24 hours at the hospital. There was no documentation of further medical evaluation or intervention. At the time of the report the patient was stable. Data was evaluated and the allegation was undetermined. The probable cause could not be determined via data. The reported glucose values fall within the D zone of the Parkes Error Grid. The data investigation did not find blood glucose calibration values to compare to CGM values during the reported sensor session or the calibrations during the reported sensor session were in accurate range per device specifications. No additional patient or event information is
Patient problems: Elevated Ketones/ Diabetic Ketoacidosis; Lethargy; Urinary Frequency / Polyuria
MAUDE report 50696291 ↗MalfunctionSep 9, 2026Wireless Communication Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50696129 ↗InjurySep 9, 2026Appropriate Device Problem Term/Code Not Available
It was reported that a wearable failure occurred. The wearable was inserted into the arm on (b)(6) 2026. The date of the event is an approximation. On 03/24/2026, the patient reported experiencing a Dexcom G7 sensor failure that displayed a "Replace Sensor" message, resulting in the loss of sensor functionality. The patient did not have a replacement sensor available at that time. The exact time of the sensor failure was unknown. No symptoms or treatment were reported immediately following the malfunction, and it was unknown whether the patient performed fingerstick blood glucose (BG) measurements after the sensor failed. On (b)(6) 2026, at an unknown time, the patient reported developing diabetic ketoacidosis (DKA) and was subsequently hospitalized. The patient stated that her blood glucose level was greater than 400 mg/dL prior to hospitalization and approximately 756 mg/dL upon arrival at the hospital. The patient reported remaining hospitalized for approximately five days, including treatment in the intensive care unit (ICU). The patient further reported that the event caused a prior bypass to fail and that she now uses a wheelchair; however, no additional information was avail
Patient problems: Elevated Ketones/ Diabetic Ketoacidosis
MAUDE report 50694521 ↗InjurySep 8, 2026Incorrect, Inadequate or Imprecise Result or Readings
It was reported that an inaccuracy between the Continuous Glucose Monitor (CGM) and the Blood Glucose (BG) meter occurred frequently between (b)(6) 2026 and (b)(6) 2026. The patient was using an Omnipod 5 pump at the time of the event. On (b)(6) 2026, the patient experienced CGM inaccurate readings and the reporter and the patient attempted to manage the situation at home for approximately one day. The spouse was unable to recall the exact CGM values but estimated a difference of approximately 20 to 30 mg/dL between the CGM readings and fingerstick blood glucose (FSBG) measurements. The reporter could not recall whether the CGM values were higher or lower than the FSBG values. The only glucose value recalled was an FSBG reading of approximately 400 mg/dL. During this period, the patient experienced symptoms consistent with hyperglycemia, including irritability, difficulty expressing himself, and speech that was difficult to understand. On (b)(6) 2026, due to ongoing concerns, the reporter transported the patient to the Emergency Department (ED). Upon arrival, the CGM continued to display inaccurate readings; however, the spouse was unable to recall the specific CGM values. She only
Patient problems: Altered State of Consciousness; Cognitive Changes; Confusion/ Disorientation; Hyperglycemia; Irritability
MAUDE report 50675600 ↗MalfunctionSep 2, 2026Unable to Obtain Readings
I had two (2) Dexcom G7 Glucose Sensor fail in a row and could not get a blood glucose reading to deliver my insulin. Both sensors are from the same lot. I am tired of having sensor after sensor fail, Dexcom product quality is dangerously poor. Dexcom put my life in danger when shipping faulty product. This is not a first time failure, on average one out of every four sensors has failed for me. The fact that the company replaces them is not a sufficient remedy. / UDI: (b)(4). (Dexcom G7 GSS (161) Integrated Continuous Glucose Monitoring System, Factory Calibrated). THIS REPORTS CAPTURES DEXCOM G7 #2. ANNEX A: 1516. ANNEX E: 4582. ANNEX G: 510. ANNEX F: 2199. REFERENCE REPORT MW6001784.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50567905 ↗MalfunctionSep 2, 2026Unable to Obtain Readings
I had two (2) Dexcom G7 Glucose Sensor fail in a row and could not get a blood glucose reading to deliver my insulin. Both sensors are from the same lot. I am tired of having sensor after sensor fail, Dexcom product quality is dangerously poor. Dexcom put my life in danger when shipping faulty product. This is not a first time failure, on average one out of every four sensors has failed for me. The fact that the company replaces them is not a sufficient remedy. / UDI: (b)(4) (Dexcom G7 GSS (161) Integrated Continuous Glucose Monitoring System, Factory Calibrated). THIS REPORTS CAPTURES DEXCOM G7 #1. ANNEX A: 1516. ANNEX E: 4582. ANNEX G: 510. ANNEX F: 2199. REFERENCE REPORT MW6001786.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50567865 ↗MalfunctionSep 1, 2026Wireless Communication Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50550534 ↗MalfunctionAug 31, 2026Wireless Communication Problem
It was reported that a signal loss occurred. No product or data was provided for evaluation. The allegation and a probable cause could not be determined. No injury or medical intervention was reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50531790 ↗MalfunctionJul 29, 2026Wireless Communication Problem
It was reported that signal loss occurred. Performance data was reviewed. The allegation was confirmed due to the finding of signal loss over an hour within the investigation window. The probable cause was determined to be transmitter timer not advancing. No injury or medical intervention was reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50065222 ↗MalfunctionJul 16, 2026Low Readings
IT WAS REPORTED THAT AN INACCURACY BETWEEN THE CONTINUOUS GLUCOSE MONITOR (CGM) AND THE BLOOD GLUCOSE (BG) METER OCCURRED. THE SENSOR WAS INSERTED INTO THE ARM, ON (b)(6) 2026. DATA WAS EVALUATED AND THE ALLEGATION WAS UNDETERMINED. IT WAS INDICATED THAT THE PATIENT WAS TAKING MEDICATION CONTAINING MORE THAN 1 GRAM (1,000 MG) ACETAMINOPHEN OVER THE COURSE OF 6 HOURS, WHICH IS OFF-LABEL USAGE OF THE DEVICE AND WHICH MAY AFFECT THE CGM READINGS.\THE PROBABLE CAUSE COULD NOT BE DETERMINED VIA DATA. THE REPORTED GLUCOSE VALUES FALL WITHIN THE D ZONE OF THE PARKES ERROR GRID. THE DATA INVESTIGATION DID NOT FIND BLOOD GLUCOSE CALIBRATION VALUES TO COMPARE TO CGM VALUES DURING THE REPORTED SENSOR SESSION OR THE CALIBRATIONS DURING THE REPORTED SENSOR SESSION WERE IN ACCURATE RANGE PER DEVICE SPECIFICATIONS. NO INJURY OR MEDICAL INTERVENTION WAS REPORTED.
Patient problems: Hyperglycemia
MAUDE report 25849408 ↗MalfunctionJul 16, 2026Detachment of Device or Device Component
IT WAS REPORTED THAT PHYSICAL DAMAGE OCCURRED. PRODUCT WAS PROVIDED FOR INVESTIGATION. AN EXTERNAL VISUAL INSPECTION WAS PERFORMED AND PASSED. PHYSICAL DAMAGE WAS NOT FOUND WITHIN THE INVESTIGATION WINDOW. THE ALLEGATION WAS NOT CONFIRMED. HOWEVER, A BROKEN OR DETACHED NEEDLE OR CANNULA WAS FOUND IN CONNECTION TO THE REPORTED EVENT. THE PROBABLE CAUSE OF THE BROKEN OR DETACHED NEEDLE OR CANNULA COULD NOT BE DETERMINED. NO INJURY OR MEDICAL INTERVENTION WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25847718 ↗MalfunctionJul 13, 2026Wireless Communication Problem
IT WAS REPORTED THAT SIGNAL LOSS OCCURRED FREQUENTLY BETWEEN (b)(6)2026-(b)(6)2026. PRODUCT WAS PROVIDED FOR INVESTIGATION. AN EXTERNAL VISUAL INSPECTION WAS PERFORMED AND PASSED. NORDIC BLUETOOTH PAIRING TEST WAS PERFORMED AND PASSED. PERFORMANCE DATA WAS REVIEWED. THE ALLEGATION WAS CONFIRMED DUE TO THE FINDING OF SIGNAL LOSS OVER ONE HOUR FREQUENTLY WITHIN THE INVESTIGATION WINDOW. THE PROBABLE CAUSE WAS THE TRANSMITTER AND APP WERE UNABLE TO ESTABLISH A CONNECTION. NO INJURY OR MEDICAL INTERVENTION WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25795856 ↗MalfunctionJul 7, 2026Wireless Communication Problem
IT WAS REPORTED THAT SIGNAL LOSS OCCURRED. PRODUCT WAS PROVIDED FOR INVESTIGATION. AN EXTERNAL VISUAL INSPECTION WAS PERFORMED AND PASSED. NORDIC BLUETOOTH PAIRING TEST WAS PERFORMED AND PASSED. PERFORMANCE DATA WAS REVIEWED. THE ALLEGATION WAS CONFIRMED DUE TO THE FINDING OF SIGNAL LOSS OVER AN HOUR WITHIN THE INVESTIGATION WINDOW. THE PROBABLE CAUSE COULD NOT BE DETERMINED. NO INJURY OR MEDICAL INTERVENTION WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25739453 ↗MalfunctionJul 7, 2026Wireless Communication Problem
IT WAS REPORTED THAT "SIGNAL LOSS" OCCURRED. NO PRODUCT OR DATA WAS PROVIDED FOR INVESTIGATION. THE ALLEGATION AND THE PROBABLE CAUSE CANNOT BE DETERMINED. NO INJURY OR MEDICAL INTERVENTION WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25738270 ↗MalfunctionJul 2, 2026Wireless Communication Problem
IT WAS REPORTED THAT SIGNAL LOSS OCCURRED. PRODUCT WAS PROVIDED FOR INVESTIGATION. AN EXTERNAL VISUAL INSPECTION WAS PERFORMED AND PASSED. NORDIC BLUETOOTH PAIRING TEST WAS PERFORMED AND FAILED. PERFORMANCE DATA WAS REVIEWED. THE ALLEGATION WAS CONFIRMED DUE TO THE FINDING OF SIGNAL LOSS OVER AN HOUR WITHIN THE INVESTIGATION WINDOW. THE PROBABLE CAUSE COULD NOT BE DETERMINED. NO INJURY OR MEDICAL INTERVENTION WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25692402 ↗MalfunctionJul 1, 2026Wireless Communication Problem
IT WAS REPORTED THAT A SIGNAL LOSS OCCURRED. NO PRODUCT OR DATA WAS PROVIDED FOR EVALUATION. THE ALLEGATION AND A PROBABLE CAUSE COULD NOT BE DETERMINED. NO INJURY OR MEDICAL INTERVENTION WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25685022 ↗
FDA clearance and classification
The FDA regulates product code QBJ (integrated continuous glucose monitoring system, factory calibrated) under 21 CFR 862.1355 as a Class II device. 21 CFR 862.1355 ↗
Devices of this type normally need 510(k) clearance before sale.
FDA definition of this device type: An integrated continuous glucose monitoring system (iCGM) is intended to automatically measure glucose in bodily fluids continuously or frequently for a specified period of time. iCGM systems are designed to reliably and securely transmit glucose measurement data to digitally connected devices, including automated insulin dosing systems, and are intended to be used alone or in conjunction with these digitally connected medical devices for the purpose of managing a disease or condition related to glycemic control.
Common questions about the Dexcom G7 GSS (161) STP-AT-013
Has the Dexcom G7 GSS (161) STP-AT-013 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00386270004116), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Dexcom G7 GSS (161) STP-AT-013?
The FDA's MAUDE database lists 16,596 adverse event reports for this device, received between May 10, 2024 and Sep 23, 2026. In those reports, the most common specific device problems are “Detachment of Device or Device Component” (6,370), “Wireless Communication Problem” (5,675) and “Low Readings” (2,328); the most common patient problems are “Hyperglycemia” (2,397), “Hypoglycemia” (566) and “Foreign Body In Patient” (491). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Dexcom G7 GSS (161) STP-AT-013?
None of the reports are classified as deaths, 388 as injuries and 16,208 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Dexcom G7 GSS (161) STP-AT-013 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Unsafe: it should not be taken into an MRI scanner room.
Who makes the Dexcom G7 GSS (161) STP-AT-013, and is it still sold?
The FDA's device database lists Dexcom, Inc. as the company responsible for it (brand Dexcom G7 GSS (161), model STP-AT-013). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Integrated Continuous Glucose Monitoring System, Factory Calibrated devices
- Dexcom G6 Transmitter 9445-24Dexcom, Inc. · Integrated Continuous Glucose Monitoring System, Factory Calibrated240,475 reports
- Dexcom G6 Transmitter 9445-02Dexcom, Inc. · Integrated Continuous Glucose Monitoring System, Factory Calibrated3 deaths229,489 reports
- Dexcom G6 Sensor Applicator Assembly 9500-45Dexcom, Inc. · Integrated Continuous Glucose Monitoring System, Factory Calibrated1 recall4 deaths114,621 reports
- US G6 Transmitter (Retail, Receiver Optional) STT-OE-002Dexcom, Inc. · Integrated Continuous Glucose Monitoring System, Factory Calibrated76,498 reports
- Dexcom G7 GSS (161) 9500-161Dexcom, Inc. · Integrated Continuous Glucose Monitoring System, Factory Calibrated70,146 reports
- Dexcom G7 iOS App SW12300Dexcom, Inc. · Integrated Continuous Glucose Monitoring System, Factory Calibrated3 recalls1 death54,855 reports
- Dexcom G7 GSS (161) STP-AT-012Dexcom, Inc. · Integrated Continuous Glucose Monitoring System, Factory Calibrated1 recall5 deaths47,762 reports
- G6 Medicare Transmitter STT-OM-001Dexcom, Inc. · Integrated Continuous Glucose Monitoring System, Factory Calibrated38,212 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page