Renuvion APYX-RS3Recalls & reported problems

Apyx Medical Corporation · Renuvion® System Generator · Class 2

All models of Renuvion (4)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
5
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00607151050115), received between Jul 15, 2022 and Jun 7, 2025 — classified as 5 injuries.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information3
  • Patient Device Interaction Problem1
  • Self-Activation or Keying1
  • Use of Device Problem1

Patient problems

  • Full thickness (Third Degree) Burn3
  • Burn(s)1
  • Low Oxygen Saturation1
  • Pain1
  • Partial thickness (Second Degree) Burn1
  • Pneumothorax1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 7, 2025Use of Device Problem; Insufficient Device Problem Information; Use of Device Problem; Insufficient Device Problem Information

    THE PATIENT APPEARED TO EXPERIENCE SUBCUTANEOUS EMPHYSEMA WITH DROP IN PERIPHERAL OXYGEN SATURATION DURING A PROCEDURE IN WHICH RENUVION WAS USED AS PART OF THE OVERALL SURGICAL TREATMENT. THE PATIENT APPEARED TO EXPERIENCE SUBCUTANEOUS EMPHYSEMA WITH DROP IN PERIPHERAL OXYGEN SATURATION DURING A PROCEDURE IN WHICH RENUVION WAS USED AS PART OF THE OVERALL SURGICAL TREATMENT.

    Patient problems: Low Oxygen Saturation; Pain; Pneumothorax

    MAUDE report 22162119 ↗
  • InjuryMar 3, 2025Self-Activation or Keying; Self-Activation or Keying

    THE PATIENT WAS BURNED BY THE UNPROMPTED ACTIVATION OF AN UNIDENTIFIED MONOPOLAR HANDPIECE DURING A PROCEDURE IN WHICH AN APYX GENERATOR WAS USED.

    Patient problems: Full thickness (Third Degree) Burn

    MAUDE report 21510528 ↗
  • InjuryOct 24, 2023Insufficient Device Problem Information; Insufficient Device Problem Information

    THE PATIENT RECEIVED A 3RD DEGREE BURN ON HER NECK.

    Patient problems: Burn(s)

    MAUDE report 17995657 ↗
  • InjuryMar 23, 2023Insufficient Device Problem Information; Insufficient Device Problem Information

    AN APYX MEDICAL SALES REPRESENTATIVE REPORTED ON 13FEB2023 THAT THEY RECEIVED A REPORT FROM (B)(6) COSMETIC SURGERY INDICATING A PATIENT EXPERIENCED BURNS AFTER A SURGICAL PROCEDURE PERFORMED ON (B)(6) 2022 IN WHICH RENUVION WAS ALSO USED AS PART OF THE OVERALL SURGICAL PROCEDURE. APYX MEDICAL CONTACTED THE OFFICE ON 01MAR2023. THE SURGEON STATED THERE WAS NO DEVICE MALFUNCTION BUT THAT THEY BELIEVE RENUVION, USED IN CONJUNCTION WITH VASER LIPOSUCTION, MAY HAVE CAUSED OR CONTRIBUTED TO THE PATIENT'S BURNS.

    Patient problems: Full thickness (Third Degree) Burn

    MAUDE report 16601548 ↗
  • InjuryJul 15, 2022Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THAT A 60 YEAR OLD VERY THIN FEMALE PATIENT WITH NO MEDICAL HISTORY AND NO PREVIOUS PROCEDURES TO THE TREATED AREA UNDERWENT MICRO-AIRE LIPOSUCTION FOLLOWED BY SUBDERMAL COAGULATION WITH RENUVION TO THE SUBMENTAL AREA. THE SURGEON REPORTED A NOTICEABLE BLISTER FORMATION IN THE TREATMENT AREA FOLLOWING 1 TREATMENT PASS OF THE RENUVION DEVICE WITH GENERATOR SETTINGS OF 20% POWER AND 4 LITER PER MINUTES (LPM) OF HELIUM FLOW. UPON DISCOVERY OF THE BLISTER, THE GENERATOR SETTINGS WERE CHANGED TO 60% POWER AND 1.5 LPM OF HELIUM FLOW, AND THE TREATMENT WAS CONTINUED TO BOTH THE RIGHT AND LEFT SIDE OF THE NECK. THE INITIAL GENERATOR SETTINGS OF 20% AND 4 LPM OF THE RENUVION DEVICE WOULD NOT HAVE CONTRIBUTED TO FORMATION OF A BLISTER AFTER ONE TREATMENT PASS AT APPROPRIATE DEVICE TREATMENT SPEEDS. CONTINUING TREATMENT FOLLOWING FORMATION OF A BLISTER IN THE TREATMENT AREA IS NOT RECOMMENDED. THE CAUSE OF THE EVENT IS UNKNOWN AT THIS TIME, BUT CONTINUING TREATMENT FOLLOWING FORMATION OF A BLISTER IN THE TREATMENT AREA IS NOT RECOMMENDED. THE GENERATOR WILL BE SENT BACK TO APYX MEDICAL CORPORATION FOR A FULL EVALUATION.

    Patient problems: Full thickness (Third Degree) Burn; Partial thickness (Second Degree) Burn

    MAUDE report 15028217 ↗