PULSAR®II PS100-100RFRecalls & reported problems

Medtronic, Inc. · GENERATOR PS100-100RF REFURB PULSAR · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00643169078406), received between Jan 13, 2020 and Nov 8, 2023 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Activation Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Activation Problem2
  • Device Damaged Prior to Use1
  • Material Separation1

Patient problems

  • Full thickness (Third Degree) Burn1
  • No Clinical Signs, Symptoms or Conditions1
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 8, 2023Activation Problem; Activation Problem

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A GENERATOR. IT WAS REPORTED THAT WHEN THE DOCTOR USED THE HANDPIECE FOR ABOUT 5 MINUTES, THEY NOTICED IT WOULD SOMETIMES OUTPUT CUT WHEN USING COAG. THEY RECONNECTED THE BLADE BUT IT PERSISTED. AFTER SWITCHING TO A NEW HANDPIECE, THE SAME ISSUE OCCURRED. THE DOCTOR CAREFULLY USED THE HANDPIECE TO COMPLETE THE PROCEDURE. ADDITIONAL INFORMATION WAS RECEIVED. IT WAS REPORTED THAT THIS OCCURRED DURING A MASTECTOMY AND THERE WAS NO DELAY AND NO IMPACT ON PATIENT OUTCOME.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18093708 ↗
  • InjuryJan 11, 2021Material Separation; Device Damaged Prior to Use; Material Separation; Device Damaged Prior to Use

    INFORMATION WAS RECEIVED FROM A HEALTHCARE PROFESSIONAL (HCP) VIA A MANUFACTURE REPRESENTATIVE (REP) REGARDING A GENERATOR AND A HANDPIECE. IT WAS REPORTED THAT DURING A PROCEDURE A PIECE OF THE HANDPIECE BEING USED CAME FREE OF THE TIP AND BURNED THE PATIENT. THE BURN WAS FULL THICKNESS, AND THE CHAR NEEDED TO BE EXCISED AND THREE SEPARATE AREAS WERE STITCHED AS A RESULT OF THIS INCIDENT. THE SUTURES NEEDED TO BE REVISED AND RE-STITCHED. IT WAS ALSO NOTED THAT THEY WERE UNABLE TO USE THE USB PORT. 5-10 MINUTES OF DELAY WHILE THE WOUNDS WERE INVESTIGATED PLUS ADDITIONAL TIME TO REVISE. IT WAS STATED THAT THERE WAS NO IMPACT TO THE PATIENT OUTCOME.

    Patient problems: Full thickness (Third Degree) Burn

    MAUDE report 11147989 ↗
  • MalfunctionJan 13, 2020Activation Problem; Activation Problem

    ADDITIONAL INFORMATION WAS RECEIVED FROM A HEALTHCARE PROFESSIONAL (HCP) VIA A MANUFACTURER REPRESENTATIVE (REP). IT WAS REPORTED THE GENERATOR WAS STILL IN USE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9583471 ↗

Other ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES devices

All ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES devices →