Bausch + Lomb INJ100Recalls & reported problems

Bausch & Lomb Incorporated · Bausch + Lomb IOL Injector 10/B · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
5
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00757770505326), received between Mar 22, 2023 and Aug 19, 2025 — classified as 5 injuries.

The most frequently reported specific device problem is “Device Difficult to Setup or Prepare” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Device Difficult to Setup or Prepare1
  • Failure to Eject1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Insufficient Information1
  • Visual Disturbances1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 19, 2025Failure to Eject; Failure to Eject

    THE HEALTH CARE FACILITY REPORTED DURING AN INTRAOCULAR LENS IOL IMPLANT PROCEDURE, THE LENS HOOKED IN THE INJECTOR. THE PROCEDURE TIME WAS PROLONGED BY APPROXIMATELY 20 MINUTES AND WAS COMPLETED WITH A DIFFERENT MODEL IOL, A CAPSULAR TENSION RING AND A SULCUS-SUTURE. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22837385 ↗
  • InjuryNov 22, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ADDITIONAL INFORMATION WAS RECEIVED INDICATING THAT REPORT RELATES TO THE PATIENT¿S LEFT EYE. THE REPLACEMENT IOL WAS A PRELOADED LENS WITH THE SAME MODEL AND DIOPTER. THE PATIENT HAS NOT NOTICED A DECREASE IN THEIR VISION.

    Patient problems: Visual Disturbances

    MAUDE report 18191013 ↗
  • InjuryJul 3, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE LEADING HAPTIC BROKE OFF WHEN INSERTING THE INTRAOCULAR LENS (IOL) INTO THE EYE. THE HAPTIC REMAINED IN THE INJECTOR CHAMBER. THE LENS WAS CUT AND THE INCISION WAS ENLARGED TO REMOVE THE LENS. ANOTHER LENS WITH THE SAME MODEL AND DIOPTER WAS SUCCESSFULLY IMPLANTED. THERE WAS NO PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17245630 ↗
  • InjuryJun 30, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REPORTEDLY, THE SURGEON DISCOVERED A BROKEN HAPTIC AFTER IMPLANTATION OF AN INTRAOCULAR LENS. THE LENS WAS REMOVED INTRAOPERATIVELY. A REPLACEMENT LENS OF THE SAME DIOPTER WAS IMPLANTED 1-WEEK POSTOP.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 17240203 ↗
  • InjuryMar 22, 2023Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare

    IT WAS REPORTED THAT AN IOL WAS INTRODUCED INTO THE PATIENT'S EYE WITH THE LEADING HAPTIC STICKING OUT AND THE TRAILING HAPTIC STUCK IN THE INJECTOR. DURING INSERTION, THE TRAILING HAPTIC THEN BROKE. THE SURGEON DECIDED TO CUT THE IOL IN HALF AND REMOVE FROM THE EYE. THE INCISION WAS ENLARGED. AN IOL OF THE SAME MODEL AND DIOPTER WAS INSERTED SUCCESSFULLY. IN THE SURGEON'S OPINION, THE LIKELY CAUSE OF THE EVENT WAS INCORRECT LOADING.

    Patient problems: No Clinical Signs, Symptoms or Conditions