Aquamantys™ 23-317-1Recalls & reported problems

Medtronic Navigation, Inc. · BIPOLAR SEALER 23-317-1 AQM ENDO DBS 8.7 · Class 2

All models of Aquamantys (12)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00763000280956), received between May 17, 2021 and Aug 14, 2026 — classified as 1 injury, 5 malfunctions.

The most frequently reported specific device problem is “Energy Output Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Energy Output Problem2
  • Failure to Shut Off2
  • No Device Output2
  • Break1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Hemorrhage/Blood Loss/Bleeding2

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 14, 2026Energy Output Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50250500 ↗
  • MalfunctionJul 28, 2025Energy Output Problem; Energy Output Problem

    INFORMATION WAS RECEIVED FROM A DISTRIBUTOR REGARDING A GENERATOR. IT WAS REPORTED THAT THE HANDPIECE COULDN'T STOP BLEEDING DURING A PROCEDURE.

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 22629634 ↗
  • InjuryJun 13, 2025No Device Output; No Device Output

    INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER REGARDING A HANDPIECE. IT WAS REPORTED THAT DURING A CASE, WHEN SITE OPENED THE PACKAGE AND USED THE HANDPIECE, IT EXPERIENCED NO OUTPUT. INITIALLY, IT WAS SUSPECTED THAT THE HOST WAS FAULTY, SO USED WITH ANOTHER HOST, BUT STILL DEVICE HAD NO OUTPUT. SITE TRIED HANDPIECE WITH TWO DIFFERENT MACHINES BUT ISSUE STILL PERSISTED. SO IT WAS REPLACED WITH A NEW HANDPIECE. ADDITIONAL INFORMATION WAS RECEIVED. IT WAS REPORTED THAT THERE WAS A SERIOUS HARM ASSOCIATED WITH PATIENT. FAILED TO USE THE DEVICE WHICH LEAD TO INCREASE BLEEDING DURING SURGERY AND REQUIRED BLOOD TRANSFUSION. THE SURGICAL PROCEDURE PERFORMED DURING THE EVENT OCCURRED WAS RIGHT HEMI LIVER RESECTION AND THERE WAS A SURGICAL DELAY OF LESS THAN ONE HOUR.

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 22202794 ↗
  • MalfunctionMar 10, 2022No Device Output; Failure to Shut Off; No Device Output; Failure to Shut Off

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A HANDPIECE. IT WAS REPORTED THAT DURING A LIVER PROCEDURE, THE HANDPIECE WAS STUCK ON ACTIVATION. THERE WAS NO IMPACT TO PATIENT OUTCOME.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13721306 ↗
  • MalfunctionFeb 22, 2022Failure to Shut Off; Failure to Shut Off

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A GENERATOR. IT WAS REPORTED THAT AFTER COMPLETION OF PROCEDURE, THE TIPS OF THE DEVICE HAD SALINE FLOW CONTINUE, AS WELL AS BIPOLAR ACTIVATION WITHOUT ANYONE DEPRESSING ACTIVATION BUTTON. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13578261 ↗
  • MalfunctionMay 17, 2021Break; Break

    INFORMATION WAS RECEIVED FROM A HEALTHCARE PROFESSIONAL (HCP) VIA A MANUFACTURE REPRESENTATIVE (REP) REGARDING A HANDPIECE. IT WAS REPORTED THAT UPON PASSING THE HANDPIECE DEVICE TO THE SURGICAL FIELD AND BEING CONNECTED TO THE EQUIPMENT, THE DOCTOR PERFORMED THE FUNCTIONAL TEST WITH THE BUTTON AND FOUND THAT THE METAL STEM WAS ROTATING ON ITS AXIS, THEN THEY TESTED IT TO COAGULATE AND REALIZE THAT IT WAS NOT THERE. WORKING AND BECAUSE THERE WAS NO PASSAGE OF ENERGY, THE DOCTOR DECIDED NOT TO USE IT AND REMOVE IT FROM THE SURGICAL FIELD. ADDITIONAL INFORMATION WAS RECEIVED AND IT WAS NOTED THAT THE TIP DID NOT BREAK OFF FROM THE HANDPIECE. THE FUNCTIONAL TEST WITH THE BUTTON AND FOUND THAT THE METAL STEM WAS ROTATING ON ITS AXIS, THEN THEY TESTED IT TO COAGULATE AND REALIZE THAT IT WAS NOT THERE. BOTH CUT AND COAG NEVER WORKED BECAUSE THE METAL PART WAS NOT MAKING CONTACT WITH THE HANDPIECE. THE GENERATOR WAS WORKING WELL. THERE WAS NO PATIENT INVOLVE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11832286 ↗

Other Electrosurgical, cutting & coagulation & accessories devices

All Electrosurgical, cutting & coagulation & accessories devices →