Xper Flex Cardio Physiomonitoring System Xper Flex Cardio FC2020 REV CRecalls & reported problems

Philips Ds North America LLC · Class 2

All models of Xper Flex Cardio Physiomonitoring System (19)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
4
Deaths reported
0
Injuries reported
1
Recalls naming it
1

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00884838084919), received between Oct 25, 2019 and Nov 4, 2021 — classified as 1 injury, 3 malfunctions.

The most frequently reported specific device problem is “Application Program Problem” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Recalls naming this device

  1. Mar 29, 2021Class IIOpen, Classified

    Performance issues with the Xper Flex Cardio Physio Monitoring System include: potential delay of up to 10 seconds in displaying ECG, invasive blood pressure and other parameters; patient weight is rounded to the nearest whole kilogram;Xper IM software used with the Xper Flex Cardio Physio Monitoring System may periodically crash; No SpO2 numeric or plethysmography is displayed when SpO2 is connected o the Flex Cardio device; display of certain data from the FC2010 becomes frozen, i.e., waveforms cease sweeping and updating and the ECG, IBP, and respiration numeric values cease to update;e ECG, IBP, and respiration waveforms become flat lines and no audible alarms are produced for HR and IBP, upon start up, an unexpected non physiological ECG waveform, erratic heart rate numeric value, and non-physiological display of any other active waveforms may appear on the Boom Monitor

    Z-1517-2021 · Root cause: Software design · Recall details · FDA record ↗

Most reported problems

Device problems

  • Application Program Problem1
  • Defibrillation/Stimulation Problem1
  • Device Alarm System1
  • Self-Activation or Keying1
  • Use of Incorrect Control/Treatment Settings1

Patient problems

  • No Known Impact Or Consequence To Patient3
  • Insufficient Information1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 4, 2021Defibrillation/Stimulation Problem; Application Program Problem; Defibrillation/Stimulation Problem; Application Program Problem

    THE CUSTOMER REPORTED THAT THE MONITORING SCREEN WENT BLANK AFTER SHOCKING (DEFIBRILLATING) A PATIENT. THE DEVICE WAS IN USE ON A PATIENT. THERE WAS NO REPORT OF PATIENT OR USER HARM.

    Patient problems: Insufficient Information

    MAUDE report 12753672 ↗
  • MalfunctionMar 19, 2020Device Alarm System

    THE CUSTOMER REPORTED ALARM ISSUE ON ALL BED SIDES. THE DEVICE WAS IN USE ON A PATIENT. THERE WAS NO REPORT OF PATIENT OR USER HARM.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9856062 ↗
  • MalfunctionOct 29, 2019Self-Activation or Keying

    THE CUSTOMER REPORTED THAT THE FLEX CARDIO SWEEP SPEED ON THE BOOM MONITOR ABRUPTLY CHANGES TO 400+ MM/SEC. THERE WAS NO REPORTED PATIENT IMPACT / INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9249420 ↗
  • MalfunctionOct 25, 2019Use of Incorrect Control/Treatment Settings

    THE CUSTOMER REPORTED THAT THE FLEX CARDIO SWEEP SPEED ON THE BOOM MONITOR ABRUPTLY CHANGED TO 400+ MM/SEC. THERE WAS NO REPORTED PATIENT IMPACT / INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9241444 ↗

Other MONITOR,PHYSIOLOGICAL,PATIENT(WITHOUT ARRHYTHMIA DETECTION OR ALARMS) devices

All MONITOR,PHYSIOLOGICAL,PATIENT(WITHOUT ARRHYTHMIA DETECTION OR ALARMS) devices →