VULCAN 7210812SRecalls & reported problems
Smith & Nephew, Inc. · VULCAN GENERATOR ONLY SERVICE REPLACEMENT · Class 2
All models of VULCAN (6)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
Quick summary
This Smith & Nephew Vulcan generator is an electrosurgical unit used for cutting and coagulation during surgery. The 31 reports mostly describe the unit shutting down or rebooting mid-procedure, failing to power up, and giving voltage calibration error messages; nearly all were service or inspection cases with no patient involved, and none describe a death or injury. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 31
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 31 adverse event reports that list this exact device (DI 03596010542182), received between Jan 8, 2018 and May 29, 2021 — classified as 31 malfunctions.
The most frequently reported specific device problem is “Unexpected Shutdown” (7 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Unexpected Shutdown7
- Protective Measures Problem6
- Calibration Problem5
- Failure to Power Up5
- Power Problem3
- Communication or Transmission Problem2
- Electrical Shorting2
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- No Patient Involvement15
- No Clinical Signs, Symptoms or Conditions13
- Burn, Thermal1
- No Consequences Or Impact To Patient1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 25 most recent of 31 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 29, 2021Calibration Problem; Calibration Problem
IT WAS REPORTED THAT THE VULCAN GENERATOR HAD VOLTAGE CALIBRATION FAIL. NO CASE REPORTED; THEREFORE, NO PATIENT WAS INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11905738 ↗MalfunctionMay 29, 2021Calibration Problem; Calibration Problem
IT WAS REPORTED THAT THE VOLTAGE CALIBRATION OF THE VULCAN GENERATOR FAILED. NO CASE REPORTED; THEREFORE, NO PATIENT WAS INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11905737 ↗MalfunctionApr 28, 2021Failure to Power Up; Failure to Power Up
IT WAS REPORTED THAT THE VULCAN GENERATOR HAD THE POWER SUPPLY BROKE DOWN. NO CASE INVOLVED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11735999 ↗MalfunctionApr 14, 2021Unexpected Shutdown; Unexpected Shutdown
IT WAS REPORTED THAT, DURING INSPECTION, THE POWER OF THE "VULCAN GENERATOR" TURNED OFF DURING OUTPUT. NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11665848 ↗MalfunctionApr 6, 2021Protective Measures Problem; Protective Measures Problem
IT WAS REPORTED THAT THE VULCAN GENERATOR HAD A "VOLTAGE CALIBRATION" FAILURE. NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11617299 ↗MalfunctionMar 27, 2021Calibration Problem; Communication or Transmission Problem; Protective Measures Problem; Calibration Problem; Communication or Transmission Problem; Protective Measures Problem
IT WAS REPORTED THAT THE SET TEMP BUTTON AND COAG BUTTON WERE FLASHING. NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. RESULTS OF INVESTIGATION HAVE CONCLUDED THAT THIS UNIT HAD A VOLTAGE CAL FAILURE WHICH MAKES IT A REPORTABLE EVENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11579351 ↗MalfunctionFeb 9, 2021Unexpected Shutdown; Unexpected Shutdown
IT WAS REPORTED THAT THE VULCAN GENERATOR WAS REBOOTING DURING OPERATION. NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11305269 ↗MalfunctionJan 18, 2021Protective Measures Problem; Protective Measures Problem
IT WAS REPORTED THAT THE VULCAN GENERATOR SHOWED A VOLTAGE CAL FAILURE MESSAGE. NO CASE INVOLVED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11184030 ↗MalfunctionDec 28, 2020Unexpected Shutdown; Unexpected Shutdown
IT WAS REPORTED THAT THE VULCAN GENERATOR POWERED OFF. NO CASE INVOLVED. THEREFORE, THERE WAS NO PATIENT INVOLVED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11085154 ↗MalfunctionDec 28, 2020Unexpected Shutdown; Unexpected Shutdown
IT WAS REPORTED THAT THE VULCAN GENERATOR POWERED OFF. NO CASE INVOLVED. THEREFORE, THERE WAS NO PATIENT INVOLVED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11085101 ↗MalfunctionDec 15, 2020Unexpected Shutdown; Unexpected Shutdown
IT WAS REPORTED THAT THE VULCAN GENERATOR POWERED OFF. NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11009212 ↗MalfunctionDec 11, 2020Failure to Power Up; Failure to Power Up
IT WAS REPORTED THAT THE VULCAN GENERATOR DOES NOT POWER ON. NO CASE WAS INVOLVED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10992573 ↗MalfunctionDec 9, 2020Unexpected Shutdown; Unexpected Shutdown
IT WAS REPORTED THAT THE VULCAN GENERATOR POWER OFF. NO CASE WAS INVOLVED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10975192 ↗MalfunctionNov 19, 2020Calibration Problem; Calibration Problem
IT WAS REPORTED THAT THE VULCAN GENERATOR HAD A "CURRENT CALIBRATION FAILURE". NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Patient Involvement
MAUDE report 10871888 ↗MalfunctionNov 18, 2020Calibration Problem; Calibration Problem
IT WAS REPORTED THAT THE VULCAN GENERATOR HAD A VOLTAGE CAL FAILURE. NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Patient Involvement
MAUDE report 10862975 ↗MalfunctionNov 12, 2020Protective Measures Problem; Protective Measures Problem
IT WAS REPORTED THAT THE VULCAN GENERATOR DISPLAYED A POWER CAL FAILURE. NO CASE WAS INVOLVED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Patient Involvement
MAUDE report 10828039 ↗MalfunctionNov 12, 2020Unexpected Shutdown; Unexpected Shutdown
IT WAS REPORTED THAT THE GENERATOR SUDDENLY HAD THE POWER DOWN. NO CASE INVOLVED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Patient Involvement
MAUDE report 10828016 ↗MalfunctionOct 26, 2020Failure to Power Up; Failure to Power Up
IT WAS REPORTED THAT, THE "VULCAN GENERATOR" POWER OFF WHEN WORKING. NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Patient Involvement
MAUDE report 10737757 ↗MalfunctionOct 22, 2020Failure to Power Up; Failure to Power Up
IT WAS REPORTED THAT THE VULCAN HAD THE POWER DOWN. NO CASE REPORTED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Patient Involvement
MAUDE report 10718246 ↗MalfunctionOct 1, 2020Protective Measures Problem; Protective Measures Problem
IT WAS REPORTED THAT THE VULCAN GENERATOR HAD A POWER CAL FAILURE ERROR. NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Patient Involvement
MAUDE report 10618258 ↗MalfunctionSep 18, 2020Power Problem; Power Problem
IT WAS REPORTED THAT THE VULCAN GENERATOR HAD NO POWER. NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Patient Involvement
MAUDE report 10554208 ↗MalfunctionSep 16, 2020Failure to Deliver Energy; Failure to Deliver Energy
IT WAS REPORTED THE VULCAN GENERATOR HAD NO OUTPUT POWER. NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Patient Involvement
MAUDE report 10543717 ↗MalfunctionSep 16, 2020Failure to Power Up; Failure to Power Up
IT WAS REPORTED THAT THE VULCAN GENERATOR HAD A POWE DROPS. NO CASE INVOLVED. THEREFORE, THERE WAS NO PATIENT INVOLVED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Patient Involvement
MAUDE report 10543382 ↗MalfunctionAug 31, 2020Communication or Transmission Problem; Communication or Transmission Problem
IT WAS REPORTED THAT THE VULCAN GENERATOR DID NOT RECOGNIZE THE RETURN ELECTRODE. NO CASE REPORTED; THEREFORE, THERE WAS NO PATIENT INVOLVEMENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Patient Involvement
MAUDE report 10474199 ↗MalfunctionAug 12, 2020Complete Loss of Power; Complete Loss of Power
IT WAS REPORTED THAT THE GENERATOR HAD A POWER SUPPLY FAILURE, THE POWER WAS DOWN. NO CASE INVOLVED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Patient Involvement
MAUDE report 10398667 ↗
Other ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES devices
- Vasoview Hemopro 2 VH-4000Maquet Cardiovascular LLC · Electrosurgical, Cutting & Coagulation & Accessories6 recalls1 death3,232 reports
- LigaSure LF1937Covidien LP · Electrosurgical, cutting & coagulation & accessories3 deaths2,090 reports
- Olympus WB91051WOLYMPUS Winter & Ibe GmbH · Electrosurgical, Cutting & Coagulation & Accessories1 death1,951 reports
- Valleylab FT10 VLFT10GENCovidien LP · Electrosurgical, cutting & coagulation & accessories1 recall5 deaths1,062 reports
- LigaSure LF1837Covidien LP · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES1 recall967 reports
- LigaSure LF2019Covidien LP · Electrosurgical, cutting & coagulation & accessories948 reports
- VAPR 225028Depuy Mitek, LLC · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES895 reports
- LigaSure LF1923Covidien LP · Electrosurgical, cutting & coagulation & accessories855 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page