STEPHANIX D2RS_9090_B1_NV2Recalls & reported problems
Stephanix · D2RS is a direct digital dynamic remote-controlled fluoroscopy and radiography system equipped with the latest generation of Flat Panel Detector (FPD). The single FPD can perform both fluoroscopy and radiography. Not for mammography. · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03664049001052), received between Jul 15, 2025 and Jul 15, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Unintended Movement” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Unintended Movement1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 15, 2025Unintended Movement; Unintended Movement
DURING A MOVEMENT ORDERED FROM THE CONSOLE BY A RADIOLOGY OPERATOR, THE TABLE DID NOT STOP. NO PATIENT, NO INJURY. THE USER DID NOT USE THE EMERGENCY STOP BUTTONS. AFTER ANALYSIS OF THE LOGS BY OUR SUPPORT TEAM, WE FOUND THAT WHEN THE TILTING CONTROL WAS RELEASED, A BUG OCCURRED IN THE INVERTERS AND MOVEMENT CONTINUED WITHOUT REACHING THE LIMIT SWITCH. WE HAVE IMPLEMENTED A HARDWARE SAFETY WHICH MONITORS IF AN ABNORMAL SITUATION LIKE THIS OCCURS AND CUTS THE POWER SO THAT THE MOVEMENT STOPS IMMEDIATELY. DURING THIS ISSUE, THE CONTACTOR FAILED TO OPEN PROPERLY AND THE EQUIPMENT REMAINED POWERED. OUR TECHNICAL TEAM ADJUSTED THE LIMIT SWITCH AND CHANGED THE CONTACTOR (MANUFACTURED BY SCHNEIDER ELECTRIC), THE COMPONENT THAT CUTS OFF THE POWER WHEN THE PROBLEM OCCURS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22506256 ↗
FDA clearance and classification
Cleared through 510(k) K213479 on Dec 23, 2021 (decision: Substantially Equivalent). Submitted by Stephanix as “D²RS and D²RS 9090”. The FDA review took 55 days. FDA record ↗
The FDA regulates product code JAA (system, x-ray, fluoroscopic, image-intensified) under 21 CFR 892.1650 as a Class II device. 21 CFR 892.1650 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the STEPHANIX D2RS_9090_B1_NV2
Has the STEPHANIX D2RS_9090_B1_NV2 been recalled?
No FDA recall record in our data names this exact device identifier (DI 03664049001052), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the STEPHANIX D2RS_9090_B1_NV2?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Jul 15, 2025. That report lists device problem “Unintended Movement” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the STEPHANIX D2RS_9090_B1_NV2?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the STEPHANIX D2RS_9090_B1_NV2 FDA approved?
It was cleared through 510(k) K213479 on Dec 23, 2021. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the STEPHANIX D2RS_9090_B1_NV2, and is it still sold?
The FDA's device database lists Stephanix as the company responsible for it (brand STEPHANIX, model D2RS_9090_B1_NV2). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other System, X-Ray, Fluoroscopic, Image-Intensified devices
- Azurion Azurion 5 M20Philips Medical Systems Nederland B.V. · System, x-ray, fluoroscopic, image-intensified9 recalls7 reports
- Azurion Azurion 3 M15Philips Medical Systems Nederland B.V. · System, x-ray, fluoroscopic, image-intensified7 recalls1 report
- Azurion Azurion 3 M12Philips Medical Systems Nederland B.V. · System, x-ray, fluoroscopic, image-intensified6 recalls4 reports
- INTERVENTIONAL ANGIOGRAPHY SYSTEM INFX-8000CCanon Inc. · System, x-ray, fluoroscopic, image-intensified5 recalls5 reports
- ProxiDiagnost N90 706110Philips Medical Systems DMC GmbH · System, X-Ray, Fluoroscopic, Image-Intensified5 recalls1 report
- Artis Q biplane 10848282Siemens Healthcare GmbH · System, x-ray, fluoroscopic, image-intensified4 recalls1 death46 reports
- CombiDiagnost R90 709031Philips Medical Systems DMC GmbH · System, x-ray, fluoroscopic, image-intensified4 recalls10 reports
- ProxiDiagnost N90 706100Philips Medical Systems DMC GmbH · System, x-ray, fluoroscopic, image-intensified4 recalls6 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page