INTERVENTIONAL ANGIOGRAPHY SYSTEM INFX-8000CRecalls & reported problems

Canon Inc. · INTERVENTIONAL ANGIOGRAPHY SYSTEM · Class 2

All models of INTERVENTIONAL ANGIOGRAPHY SYSTEM (3)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

5 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
5
Deaths reported
0
Injuries reported
2
Recalls naming it
5

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 04987670100192), received between Feb 12, 2025 and Sep 19, 2026 — classified as 2 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

5 FDA recall records name this device's identifier, 5 still open.

7 other recalls cover devices cleared under the same FDA submission (K113052, K152697, K181804); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 1 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Oct 12, 2026Class IIOpen, Classified

    Due to software issue, X-ray interventional system may experience internal error if F-Store or imagine acquisition is performed while clinical analysis function is use.

    Z-0289-2027 · Root cause: Software design · Recall details · FDA record ↗

  2. Aug 26, 2026Class IIOpen, Classified

    Loosening of the bolts securing the longitudinal movement mechanism may cause the tabletop to shift, resulting in [positional/imaging/patient] misalignment and a longitudinal motion error

    Z-0108-2027 · Root cause: Process control · Recall details · FDA record ↗

  3. Nov 15, 2023Class IIOpen, Classified

    VAREX changed the manufacturing of the internal board, and the detectors displayed abnormal images. Internal board of the X-ray flat panel detector may display abnormal images, such as horizontal stripes, which may lead to the inability to complete an ongoing exam, or the patient may need to be examined with another x-ray system.

    Z-1154-2024 · Root cause: Component change control · Recall details · FDA record ↗

  4. Jun 22, 2023Class IIOpen, Classified

    The C-arm, used to set the position and angle of the x-ray exposure field, may not function due to the tableside console PWB, which needs replacement. There may be a delay in the procedure, but procedures can continue using the operators console, the switches on the back of the column, switches on the side of the flat panel detector, and the emergency stop will continue to function normally.

    Z-2392-2023 · Root cause: Nonconforming Material/Component · Recall details · FDA record ↗

  5. May 3, 2022Class IIOpen, Classified

    CT operation may be restricted by an interlock which is a result of an system error and the CT system may stop operating properly after an attempt to cancel the error message has been initiated.

    Z-1289-2022 · Root cause: Software design · Recall details · FDA record ↗

Most reported problems

Device problems

  • Appropriate Device Problem Term/Code Not Available1
  • Detachment of Device or Device Component1
  • Device Handling Problem1
  • Insufficient Device Problem Information1
  • Unexpected Mode Switch1
  • Unintended Movement1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Bone Fracture(s)1
  • Cardiac Arrest1
  • Muscle/Tendon Damage1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjurySep 19, 2026Insufficient Device Problem Information; Device Handling Problem

    Based on the patient's anatomy and the location of the abdominal lesion, the patient was required to be positioned in a left lateral oblique position for the procedure. The patient was transferred from the stretcher to the interventional radiology examination table and repositioned to ensure proper centering and alignment on the table. Additional lateral support holders were applied for patient support and positioning. While turning the patient to place a positioning pillow beneath the patient's right side, the left-sided support holder failed, resulting in the patient falling from the procedure table to the procedure room floor. The patient initially landed on the left shoulder and subsequently onto back. A laceration to the left lateral aspect of the patient's head was identified with associated some bleeding. Cardiac monitoring leads and pulse oximetry was applied, and the patient remained hemodynamically stable. A full-body CT scan was performed. The patient suffered a broken clavicle, several bruises and lacerations but no head trauma.\Canon Field Service Representative spoke to the customer Biomed who acknowledged that the Domico arm supports are not designed to serve as pati

    Patient problems: Bone Fracture(s)

    MAUDE report 50831653 ↗
  • MalfunctionAug 7, 2026Detachment of Device or Device Component

    Patient was undergoing a lumbar puncture procedure. Patient was lying prone, and IR technologist was operating equipment between AP and lateral positions to guide needle into spinal canal for procedure. Technologist was using preset to move c-arm from a lateral position into an AP position. During this movement, the c-arm made a noise indicating that something touched the machine. Technologist stopped movements and went to float the table towards the foot when there was a loud bang and the table snapped in half. The patient's head went down towards the arm of the c-arm and the patient was held by an RN to prevent falling on the ground. Needle was removed from the patient's back by the technologist. Patient was held by staff until another RN was able to come and help slide patient towards the base of the table, to get off the broken table portion, to allow transfer back onto stretcher safely. Patient stated he bumped his forehead on the arm of the c-arm, but there was no scratch, bump, or bruise. Patient did state in the next room it did not hurt at all. Procedure was completed in alternate room.\\Patient was assessed by radiologist and nursing staff and no injury sustained. The RN

    Patient problems: Muscle/Tendon Damage

    MAUDE report 50168707 ↗
  • InjuryMar 13, 2026Appropriate Device Problem Term/Code Not Available

    ON (B)(6) 2026, AT A (B)(6) HOSPITAL DURING AN EXAMINATION THE DOCTOR TRIED TO MOVE AROUND WHILE AVOIDING A LARGE MONITOR WHICH WAS ON THE CEILING SUSPENSION STAND. HOWEVER, HE STOOD UP BEFORE HE COULD COMPLETELY AVOID THE MONITOR, CAUSING THE TOP OF THE DOCTOR'S HEAD TO COLLIDE WITH THE CORNER OF THE MONITOR. THIS RESULTED IN A LACERATION ON THE TOP RIGHT SIDE OF THE DOCTOR'S HEAD, THAT REQUIRED STITCHES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24594951 ↗
  • MalfunctionDec 17, 2025Unexpected Mode Switch; Unexpected Mode Switch

    DURING USE OF STENT ENHANCE ON (B)(6) 2025 THE SYSTEM LOCKED UP. AFTER SYSTEM LOCK UP, STAFF FORCED SHUTDOWN AND WAS ABLE TO REBOOT ONLY AFTER MULTIPLE ATTEMPTS. DURING THIS TIME, TOTALING MORE THAN 30 MINUTES STAFF WERE UNABLE TO PERFORM FLUORO OR DA AND PATIENT WENT INTO CARDIAC ARREST. AFTER SYSTEM REBOOT THE SYSTEM OPERATED NORMALLY AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: Cardiac Arrest

    MAUDE report 23832810 ↗
  • MalfunctionFeb 12, 2025Unintended Movement; Unintended Movement

    ON JANUARY 15TH AT A JAPANESE HOSPITAL AFTER THE C-ARM WAS MOVED TO THE PARK POSITION, THE C-ARM MOVED DUE TO USER OPERATION ERROR. AFTER COLLIDING WITH THE SHELF, AN ERROR MESSAGE WAS DISPLAYED AND THE C-ARM STOPPED. THE SHELF WAS SLIGHTLY DAMAGED, BUT THERE WAS NO HARM TO THE PATIENT OR STAFF. INVESTIGATION DETERMINED THEIR WAS NO ISSUE WITH THE DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21368490 ↗

FDA clearance and classification

Cleared through 510(k) K181804 on Aug 2, 2018 (decision: Substantially Equivalent). Submitted by Canon Medical Systems Corporation as “Alphenix, INFX-8000C/B, V8.0”. The FDA review took 27 days. FDA record ↗

Cleared through 510(k) K152697 on Jan 15, 2016 (decision: Substantially Equivalent). Submitted by Toshibamedical Systems Corporation as “Infx-8000c, V6.20”. The FDA review took 116 days. FDA record ↗

Cleared through Special 510(k) K113052 on Nov 22, 2011 (decision: Substantially Equivalent). Submitted by Toshiba America Medical Systems, In.C as “Infinix-Cci”. The FDA review took 40 days. FDA record ↗

The FDA regulates product code JAA (system, x-ray, fluoroscopic, image-intensified) under 21 CFR 892.1650 as a Class II device. 21 CFR 892.1650 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K113052, K152697, K181804. One submission often covers many models, so check the product and lot details in each record.

  • Z-0492-2022 · Dec 20, 2021 · Open, Classified
    Flat Panel Detector, Model Number: TFP-800A, used with the Alphenix Systems, Item Numbers: INFX-8000V, INFX-8000C, INFX-8000F, and INFX-8000H.
  • Z-1175-2021 · Feb 5, 2021 · Open, Classified
    System INFX-8000C
  • Z-1270-2021 · Dec 8, 2020 · Open, Classified
    Canon INTERVENTIONAL ANGIOGRAPHY SYSTEM MODEL INFX-8000C Catheterization Table CAT-880B Canon CATHETERIZATION TABLE, MODEL CAT-880B INPUT 220V - Product Usage: indicated for use i
  • Z-0532-2021 · Oct 8, 2020 · Terminated
    CAS-930A Flat Panel Monitor (FPD) used in conjunction with the Canon Interventional Angiography System, Model numbers: Infinix-8000C and Infinix-8000H - Product Usage: This device
  • Z-2326-2020 · Mar 3, 2020 · Open, Classified
    Infinix-8000C with Catheterization Table CAT-850B or CAT-860B - Product Usage: This device is a digital radiography/fluoroscopy system used in a diagnostic and interventional angio
  • Z-0843-2018 · Dec 29, 2017 · Terminated
    INFX-8000C Fluoroscopic X-Ray Systems
  • Z-0994-2013 · Nov 8, 2012 · Terminated
    Toshiba Infinix-i X-Ray System. A radiographic and fluoroscopic x-ray system for use in diagnostic and angiographic procedures.

Common questions about the INTERVENTIONAL ANGIOGRAPHY SYSTEM INFX-8000C

Has the INTERVENTIONAL ANGIOGRAPHY SYSTEM INFX-8000C been recalled?

Yes. 5 FDA recall records name this device's identifier: 5 still open. The most recent, Z-0289-2027 (Class II), began on Oct 12, 2026: Due to software issue, X-ray interventional system may experience internal error if F-Store or imagine acquisition is performed while clinical analysis function is use. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

What problems have been reported with the INTERVENTIONAL ANGIOGRAPHY SYSTEM INFX-8000C?

The FDA's MAUDE database lists 5 adverse event reports for this device, received between Feb 12, 2025 and Sep 19, 2026. In those reports, the most common specific device problems are “Detachment of Device or Device Component” (1), “Device Handling Problem” (1) and “Unexpected Mode Switch” (1); the most common patient problems are “Bone Fracture(s)” (1), “Cardiac Arrest” (1) and “Muscle/Tendon Damage” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the INTERVENTIONAL ANGIOGRAPHY SYSTEM INFX-8000C?

None of the reports are classified as deaths, 2 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the INTERVENTIONAL ANGIOGRAPHY SYSTEM INFX-8000C FDA approved?

It was cleared through Special 510(k) K113052 on Nov 22, 2011; its record lists 3 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the INTERVENTIONAL ANGIOGRAPHY SYSTEM INFX-8000C, and is it still sold?

The FDA's device database lists Canon Inc. as the company responsible for it (brand INTERVENTIONAL ANGIOGRAPHY SYSTEM, model INFX-8000C). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other System, x-ray, fluoroscopic, image-intensified devices

All System, x-ray, fluoroscopic, image-intensified devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page