Olympus WA69320MRecalls & reported problems

OLYMPUS Winter & Ibe GmbH · Jaws insert "HICURA", 5 x 330, CroceOlmi, monopolar · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 04042761079297), received between May 16, 2018 and May 5, 2026 — classified as 2 injuries, 6 malfunctions.

The most frequently reported specific device problem is “Break” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break6
  • Fracture2
  • Material Fragmentation2
  • Mechanical Problem2
  • Material Deformation1
  • Structural Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • Foreign Body In Patient2
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 5, 2026Break

    IT WAS REPORTED THAT THE RIGID ENDOSCOPIC TISSUE MANIPULATION FORCEPS, REUSABLE HAD THE TIP OF THE DEVICE BENT AND FELL OFF . THE ISSUE WAS OBSERVED DURING AN UNSPECIFIED THERAPEUTIC PROCEDURE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: Foreign Body In Patient

    MAUDE report 25084371 ↗
  • MalfunctionJan 16, 2026Structural Problem

    THERE IS NO NEW INFORMATION PROVIDED BY THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24105062 ↗
  • MalfunctionSep 21, 2023Break; Break

    THE CUSTOMER REPORTED TO OLYMPUS THAT ONE OF THE JAWS BROKE OFF DURING REPROCESSING. THERE WERE NO REPORTS OF PATIENT HARM OR IMPACT ASSOCIATED WITH THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17787612 ↗
  • MalfunctionAug 2, 2023Material Deformation; Material Deformation

    THE CUSTOMER REPORTED THAT THE TIP OF JAWS WAS DISTORTED. THE ISSUE WAS DISCOVERED WHEN THE PRODUCT WAS PURCHASED. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17441757 ↗
  • MalfunctionJul 3, 2023Break; Break

    THE CUSTOMER REPORTED THAT THE FORCEPS BROKE WITH A CRACKING SOUND. NO PARTS FELL OUT OF THE BODY. THE REPORTED ISSUE WAS OBSERVED DURING A THERAPEUTIC LAPAROSCOPY. THE INTENDED PROCEDURE WAS COMPLETED USING OTHER FORCEPS. THERE WAS NO PATIENT OR USER INJURY REPORTED DUE TO THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17248855 ↗
  • InjuryJul 3, 2023Break; Break

    THE CUSTOMER REPORTED TO OLYMPUS THAT DURING AN UNSPECIFIED THERAPEUTIC SURGERY, THE TIP OF THIS FORCEPS BROKE AND FELL INTO THE PATIENT'S BODY. THE BROKEN PART WAS RECOVERED. THE PROCEDURE WAS COMPLETED WITH SIMILAR DEVICE. THERE WERE NO REPORTS OF FURTHER PATIENT OR USER HARM ASSOCIATED WITH THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17246550 ↗
  • InjurySep 23, 2022Break; Fracture; Material Fragmentation; Mechanical Problem; Break; Fracture; Material Fragmentation; Mechanical Problem

    OLYMPUS WAS INFORMED THAT DURING REPROCESSING AFTER A THERAPEUTIC LAPAROSCOPIC ASCENDING COLECTOMY PROCEDURE, IT WAS NOTICED THAT A PART OF THE CURVED TIP AT THE DISTAL END OF THE JAWS INSERT WAS MISSING. CONSEQUENTLY, AN X-RAY EXAMINATION WAS PERFORMED AND THE MISSING FRAGMENT WAS LOCATED INSIDE THE PATIENT. AN ADDITIONAL SURGERY WAS CARRIED OUT AND THE BROKEN FRAGMENT WAS SUCCESSFULLY RETRIEVED.

    Patient problems: Foreign Body In Patient

    MAUDE report 15474573 ↗
  • MalfunctionMay 16, 2018Break; Fracture; Material Fragmentation; Mechanical Problem; Break; Fracture; Material Fragmentation; Mechanical Problem

    OLYMPUS WAS INFORMED THAT DURING A THERAPEUTIC COLONOSCOPY PROCEDURE, THE JAWS AT THE DISTAL END OF THE SUSPECT MEDICAL DEVICE BROKE WHILE GRIPPING THE LARGE INTESTINE AND A FRAGMENT FELL INSIDE THE PATIENT. HOWEVER, NO FRAGMENT REMAINED INSIDE THE PATIENT SINCE IT WAS REPORTEDLY RETRIEVED. THE INTENDED PROCEDURE WAS SUCCESSFULLY COMPLETED WITH THE SAME SET OF EQUIPMENT AND THERE WAS NO REPORT ABOUT AN ADVERSE EVENT OR PATIENT INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7517541 ↗

Other Electrosurgical, Cutting & Coagulation & Accessories devices

All Electrosurgical, Cutting & Coagulation & Accessories devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page