Legato® JMPP27025Recalls & reported problems
Joimax GmbH · Legato® Probe monopolar, Ball Tip · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04250337103745), received between Aug 1, 2023 and Aug 1, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Device Damaged by Another Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device Damaged by Another Device1
Patient problems
- Full thickness (Third Degree) Burn1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 1, 2023Device Damaged by Another Device; Device Damaged by Another Device
ON JUNE 7, 2023 THE MANUFACTURER BECAME AWARE THAT THERE HAD BEEN COMPLICATIONS DURING ENDOSCOPIC SPINAL SURGERY WITH A MONOPOLAR JOIMAX LEGATO PROBE SOMETIME ON OR AFTER (B)(6) 2022; HOWEVER, LIMITED DETAILS WERE SUPPLIED AND THE EVENT SERIOUSNESS WAS NOT KNOWN. JOIMAX CONTACTED THE SURGEON TO REQUEST ADDITIONAL INFORMATION, AND ON JULY 4, 2023 LEARNED THAT THE PATIENT SUSTAINED THIRD-DEGREE BURNS. ON JULY 10, 2023, THE SURGEON PROVIDED THE FOLLOWING ADDITIONAL INFORMATION. THE MONOPOLAR LEGATO PROBE (AND HANDLE) WERE USED WITH THE FOLLOWING OTHER SURGICAL INSTRUMENTS: ERBE RF GENERATOR (VIO 3 IN FORCED COAG MODE WITH SETTING 6.0), ERBE NEUTRAL ELECTRODE, RIWOSPINE INSTRUMENT TRAY AND ENDOSCOPE. THE PATIENT EXPERIENCED BURNS AT THE SITE OF ENDOSCOPIC SPINAL ACCESS AND SKIN BURNS IN THE THIGH AREA WHERE THE NEUTRAL ELECTRODE WAS CONTACTED. THE BURN WAS CHARACTERIZED AS NECROTIC, WHITE SKIN WITH BLEEDING AND BLISTERING. DURING SURGERY, THE ERBE NEUTRAL ELECTRODE GENERATED TWO ERROR MESSAGES REGARDING CONTACT PROBLEMS; THE ERRORS WERE REMEDIED BY IMMEDIATELY PRESSING THE NEUTRAL ELECTRODE ON THE THIGH. ACCORDING TO THE SURGEON, THESE ERRORS MAY HAVE BEEN RELATED TO INADEQUATE PREOPER
Patient problems: Full thickness (Third Degree) Burn
MAUDE report 17437946 ↗
Other Electrosurgical, Cutting & Coagulation & Accessories devices
- Vasoview Hemopro 2 VH-4000Maquet Cardiovascular LLC · Electrosurgical, Cutting & Coagulation & Accessories6 recalls1 death3,232 reports
- LigaSure LF1937Covidien LP · Electrosurgical, cutting & coagulation & accessories3 deaths2,090 reports
- Olympus WB91051WOLYMPUS Winter & Ibe GmbH · Electrosurgical, Cutting & Coagulation & Accessories1 death1,951 reports
- Valleylab FT10 VLFT10GENCovidien LP · Electrosurgical, cutting & coagulation & accessories1 recall5 deaths1,062 reports
- LigaSure LF1837Covidien LP · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES1 recall967 reports
- LigaSure LF2019Covidien LP · Electrosurgical, cutting & coagulation & accessories948 reports
- VAPR 225028Depuy Mitek, LLC · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES895 reports
- LigaSure LF1923Covidien LP · Electrosurgical, cutting & coagulation & accessories855 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page