COLORADO N104ARecalls & reported problems
Stryker Leibinger GmbH & Co. KG · MicroDissection Needle straight sleeve · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04546540004116), received between Jul 1, 2020 and Feb 26, 2021 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Fracture1
- Sparking1
Patient problems
- Burn(s)1
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
- Superficial (First Degree) Burn1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryFeb 26, 2021Sparking; Sparking
IT WAS REPORTED THAT DURING THE PROCEDURE, THE SURGEON USED THE COLORADO NEEDLE ALONG WITH THE BOVIE ON THE PATIENT¿S LEFT CHEEK AND THE BOVIE SPARKED WHILE IN USE AND LIT THE DRY COTTON BALL, PLACED IN PATIENTS EAR, ON FIRE. THERE WAS A SALINE QUICKLY POURED OVER TO EXTINGUISH THE FLAME. PATIENT¿S LEFT EAR WAS NOTED TO BE RED AND AN ANTIBIOTIC OINTMENT WAS PUT ON IT. THERE IS NO OTHER INFORMATION KNOWN AT THIS TIME.
Patient problems: Burn(s); Superficial (First Degree) Burn
MAUDE report 11388783 ↗MalfunctionJul 1, 2020Fracture; Fracture
IT WAS REPORTED THAT THE TIP OF THE ELECTRODE BROKE WHEN USING THE COLORADO NEEDLE INTRA-OPERATIVELY. THE PROCEDURE WAS COMPLETED USING A BACKUP COLORADO NEEDLE, AND NO ADVERSE CONSEQUENCES WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Known Impact Or Consequence To Patient
MAUDE report 10219444 ↗
Other ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES devices
- Vasoview Hemopro 2 VH-4000Maquet Cardiovascular LLC · Electrosurgical, Cutting & Coagulation & Accessories6 recalls1 death3,232 reports
- LigaSure LF1937Covidien LP · Electrosurgical, cutting & coagulation & accessories3 deaths2,090 reports
- Olympus WB91051WOLYMPUS Winter & Ibe GmbH · Electrosurgical, Cutting & Coagulation & Accessories1 death1,951 reports
- Valleylab FT10 VLFT10GENCovidien LP · Electrosurgical, cutting & coagulation & accessories1 recall5 deaths1,062 reports
- LigaSure LF1837Covidien LP · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES1 recall967 reports
- LigaSure LF2019Covidien LP · Electrosurgical, cutting & coagulation & accessories948 reports
- VAPR 225028Depuy Mitek, LLC · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES895 reports
- LigaSure LF1923Covidien LP · Electrosurgical, cutting & coagulation & accessories855 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page