LeVeen™ Standard M001262130Recalls & reported problems
Boston Scientific Corporation · Needle Electrode System · Class 2
All models of LeVeen Standard (6)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08714729295594), received between Sep 6, 2018 and Mar 9, 2023 — classified as 2 injuries, 1 malfunction.
The most frequently reported specific device problem is “Defective Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Defective Device1
- Failure to Unfold or Unwrap1
- Therapeutic or Diagnostic Output Failure1
Patient problems
- Bradycardia1
- Burn(s)1
- Cardiac Arrest1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 9, 2023Failure to Unfold or Unwrap; Defective Device; Therapeutic or Diagnostic Output Failure; Failure to Unfold or Unwrap; Defective Device; Therapeutic or Diagnostic Output Failure
IT WAS REPORTED THAT THE ARRAY DID NOT DEPLOY PROPERLY, AND INSUFFICIENT ROLL OFF OCCURRED. A 4.0/14/15 LEVEEN STANDARD PROBE WAS SELECTED FOR USE IN A RADIO FREQUENCY ABLATION PROCEDURE IN A METASTATIC LUNG TUMOR. DURING THE PROCEDURE, THE HANDLE OF THE NEEDLE WAS COMPLETELY LOOSE, AND THE PEAK OF THE NEEDLE SLIPPED OUT COMPLETELY WITH MINIMAL FORWARD MOVEMENT. THE NEEDLE WAS STUCK IN THE TUMOR, AND AFTER DEPLOYMENT OF THE ARRAY, THE WHITE PLASTIC END SLIPPED BACK, SO THE NEEDLE WAS NOT COMPLETELY OPEN. TREATMENT WAS PERFORMED WITH TWO CYCLES, BUT THERE WAS NO ROLL OFF. THE NEEDLE WAS NOT EXCHANGED SINCE THERE WERE NO ADDITIONAL NEEDLES AVAILABLE. NO PATIENT COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16515745 ↗InjuryOct 19, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE NEEDLE CAUSED A BURN. A RADIO FREQUENCY ABLATION PROCEDURE WAS BEING PERFORMED ON A TUMOR FOR A PATIENT WITH LIVER CANCER. THE LEVEEN STANDARD WAS BEING USED FOR THIS PROCEDURE. WHEN THE NEEDLE WAS IN POSITION AND THE ABLATION WAS OCCURRING THE NEEDLE WAS HOT AND SMOKING WHICH RESULTED IN THE PATIENT BECOMING BURNED. THE PROCEDURE WAS COMPLETED WITH THIS DEVICE. AFTER THE PROCEDURE, THE PATIENT WAS CONSIDERED STABLE.
Patient problems: Burn(s)
MAUDE report 10697370 ↗InjurySep 6, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THE PATIENT EXPERIENCED BRADYCARDIA AND A BRIEF PERIOD OF ASYSTOLE. PRELIMINARY ULTRASONOGRAPHY SHOWED A 1.3X1.6 CM HYPOECHOUC NODULE IN HEPATIC SEGMENT VI. THE PATIENT WAS PREPARED IN SUPINE POSITION UNDER ASEPTIC DRAPING AND COMBINED GENERAL-LOCAL ANESTHESIA FOR A RADIOFREQUENCY ABLATION (RFA) PROCEDURE. A 4.0 CM LEVEEN RFA NEEDLE WAS NAVIGATED INTO THE NODULE ULTRASONOGRAPHIC GUIDANCE. ABLATION WAS PERFORMED AND DURING FIRST POSITION OF ABLATION (ABOUT 10 MINS AT ABOUT 170 WATTS) WITH 4.0 DIAMETER OF EXPANSION, THE PATIENT DEVELOPED BRADYCARDIA (HEART RATE FROM 80 BPM TO 30 BPM) AND THEN ASYSTOLE (DURATION ABOUT 2-3 SECONDS) AND SPONTANEOUS RECOVERY. THE EVENTS OF BRADYCARDIA OCCURRED ABOUT 5-6 CYCLES. 0.3 MG OF ATROPINE WAS GIVEN BY ANESTHESIOLOGIST. THEN THE SESSION WAS STOPPED. TOTAL ABLATIVE TIME WAS ABOUT 13 MINUTES. RE-ABLATION WAS DONE AT 130 WATTS AND THE PATIENT DEVELOPED BRADYCARDIA AGAIN. THE SESSION WAS THEN TERMINATED. MILD HYPERECHOIC CHANGE WAS SEEN AND THE TRACT WAS ABLATED. THE PATIENT'S CONDITION WAS STABLE.
Patient problems: Bradycardia; Cardiac Arrest
MAUDE report 7850430 ↗
Other ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES devices
- Vasoview Hemopro 2 VH-4000Maquet Cardiovascular LLC · Electrosurgical, Cutting & Coagulation & Accessories6 recalls1 death3,232 reports
- LigaSure LF1937Covidien LP · Electrosurgical, cutting & coagulation & accessories3 deaths2,090 reports
- Olympus WB91051WOLYMPUS Winter & Ibe GmbH · Electrosurgical, Cutting & Coagulation & Accessories1 death1,951 reports
- Valleylab FT10 VLFT10GENCovidien LP · Electrosurgical, cutting & coagulation & accessories1 recall5 deaths1,062 reports
- LigaSure LF1837Covidien LP · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES1 recall967 reports
- LigaSure LF2019Covidien LP · Electrosurgical, cutting & coagulation & accessories948 reports
- VAPR 225028Depuy Mitek, LLC · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES895 reports
- LigaSure LF1923Covidien LP · Electrosurgical, cutting & coagulation & accessories855 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page