Enseal NSLG2C45Recalls & reported problems

Ethicon Endo-Surgery, LLC · Enseal Laparoscopic Tissue Sealer G2 Curved Jaw for use with G2 Generator 5mm Diameter 45cm Shaft length · Class 2

All models of Enseal (24)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
12
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 12 adverse event reports that list this exact device (DI 10705036014157), received between May 10, 2018 and Jun 27, 2024 — classified as 1 injury, 11 malfunctions.

The most frequently reported specific device problem is “Difficult to Open or Close” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Open or Close3
  • Material Integrity Problem2
  • Mechanical Problem2
  • Break1
  • Detachment of Device or Device Component1
  • Device Operates Differently Than Expected1
  • Difficult or Delayed Activation1
  • Material Separation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6
  • No Consequences Or Impact To Patient5
  • Blood Loss1

Recent adverse event reports

The 12 most recent of 12 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 27, 2024Difficult or Delayed Activation; Difficult or Delayed Activation

    IT WAS REPORTED THE PRODUCT RANDOMLY STOPPED WORKING 30 MINUTES INTO THE A CARACSOTHAGEL HERNIA REPAIR. THEY GOT A NEW DEVICE TO COMPLETE THE REST OF THE CASE WITHOUT PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19624800 ↗
  • MalfunctionJul 18, 2023Difficult to Open or Close; Difficult to Open or Close

    IT WAS REPORTED THAT DURING THE UNKNOWN PROCEDURE THE DEVICE WOULD NOT OPEN OR CLOSE. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17343835 ↗
  • MalfunctionApr 10, 2023Difficult to Open or Close; Difficult to Open or Close

    IT WAS REPORTED THAT DURING A LAPAROSCOPIC SLEEVE GASTRECTOMY PROCEDURE THAT THE ¿TRIGGER WOULDN¿T FULLY RELEASE WHEN OPERATED¿. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE CONSEQUENCES FOR THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16709335 ↗
  • MalfunctionFeb 16, 2023Difficult to Open or Close; Difficult to Open or Close

    IT WAS REPORTED THAT DURING A SLEEVE GASTRECTOMY, WHEN THE SURGEON OPENED THE DEVICE AND TRIED TO USE IT, THIS WAS BLOCKED AND THEY COULDN'T OPEN IT. THE DEVICE WASN'T ACTIVATED, SO THERE WAS NO PATIENT ADVERSE EVENT. THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16386166 ↗
  • MalfunctionOct 17, 2022Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE THE JAW WAS BROKEN. THERE WERE NO PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15616101 ↗
  • MalfunctionJan 13, 2022Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT, DURING KIDNEY AND ADRENAL GLAND PROCEDURE WITH DA VINCI, I-BLADE WAS BROKEN DURING USE. BROKEN PIECE HAS BEEN RETRIEVED. NO PIECES FELL INTO THE PATIENT. GEN11 WAS USED. ANOTHER DEVICE WAS USED TO COMPLETE THE CASE. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13251912 ↗
  • MalfunctionMar 19, 2020Mechanical Problem; Mechanical Problem

    IT WAS REPORTED THAT DURING A LAPAROSCOPIC DUODENAL SWITCH THE DEVICE FAILED TO ACTIVATE/MALFUNCTIONED AFTER INITIAL USE. A SECOND DEVICE WAS OPENED AND HAD THE SAME ISSUE. A THIRD DEVICE WAS USED TO COMPLETE THE CASE WITH NO PATIENT CONSEQUENCES.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9856952 ↗
  • MalfunctionAug 2, 2019Material Separation; Material Separation

    IT WAS REPORTED THAT THE DEVICE BLOCKED INTRAOPERATIVELY AND THE DEVICE DID NOT CUT. INSTRUMENT COULD BE EASILY OPENED AND REMOVED FROM THE TISSUE. AN ADDITIONAL DEVICE WAS OPENED AND THE OP ENDED WITH NO INFLUENCE ON SURGERY AND PAT. SAFETY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8856765 ↗
  • MalfunctionAug 2, 2019Mechanical Problem; Mechanical Problem

    IT WAS REPORTED THAT AT AN UNKNOWN TIME THE JAWS OF THE DEVICE WOULD NOT OPEN. IT IS UNKNOWN IF THERE WERE ANY ADVERSE PATIENT CONSEQUENCES.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8855316 ↗
  • MalfunctionOct 29, 2018Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE, THE TIP OF THE JAW IS DETACHED. NO PATIENT CONSEQUENCE REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8014736 ↗
  • MalfunctionJun 22, 2018Break

    IT WAS REPORTED THAT DURING A SLEEVE GASTRECTOMY PROCEDURE, THE DEVICE GRASPING METAL BITS FELL APART WHILE USING INSIDE THE PATIENTS ABDOMEN. THE FALLEN PIECE WAS RETRIEVED. A NEW DEVICE WAS OPENED TO COMPLETE THE PROCEDURE. NO IMPACT TO THE PATIENT. THE PROCEDURE WAS DELAYED 20 MINUTES.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7629704 ↗
  • InjuryMay 10, 2018Device Operates Differently Than Expected

    IT WAS REPORTED THAT DURING A SLEEVE GASTRECTOMY PROCEDURE, THE SURGEON WAS LOOKING TO TRANSECT THE SHORT GASTRIC ARTERY CLOSE TO THE SPLEEN. THE ENSEAL WAS CLOSED AND ALL TONES WERE HEARD. WHEN THE DEVICE WAS OPENED IT HAD CUT THE VESSEL BUT NOT SEALED IT. A VASCULAR SURGEON WAS CALLED IN TO ASSIST. THE PATIENT WAS OPENED TO CONTROL THE BLEEDING BUT THE PROCEDURE WAS COMPLETED LAPAROSCOPIC. THE PATIENT ENDED UP LOSING LARGE VOLUME OF BLOOD, 3.5 L. THE PATIENT WAS TRANSFERRED TO ICU FOR 24 HRS.

    Patient problems: Blood Loss

    MAUDE report 7503261 ↗

Other ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES devices

All ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES devices →