Edge E1455BNSBRecalls & reported problems
Covidien LP · Insulated Blade Electrode Safety Sleeve(TM);Caution: For manufacturing,processing, or repacking. · Class 2
All models of Edge (43)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10884521038479), received between Aug 31, 2018 and Aug 31, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Contamination /Decontamination Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Contamination /Decontamination Problem1
- Detachment of Device or Device Component1
- Peeled/Delaminated1
Patient problems
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 31, 2018Peeled/Delaminated; Contamination /Decontamination Problem; Detachment of Device or Device Component; Peeled/Delaminated; Contamination /Decontamination Problem; Detachment of Device or Device Component
ACCORDING TO THE REPORTER, DURING PROCEDURE, THE INSULATION OF THE BLADE TIP BROKE IN PIECES AT THE TIME OF MAKING AN INCISION. SOME PIECES FELL INTO THE PATIENT¿S CAVITY, BUT THE PIECES COULD NOT BE LOCATED ON EITHER INSIDE THE PATIENT¿S CAVITY AND OUTSIDE THE CAVITY. IT WAS NOTED THAT THE CAUSED OF THE ISSUE WAS DUE TO DEVICE HAD BEEN ON ELECTRON BEAM STERILIZATION.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 7839127 ↗
Other ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES devices
- Vasoview Hemopro 2 VH-4000Maquet Cardiovascular LLC · Electrosurgical, Cutting & Coagulation & Accessories6 recalls1 death3,232 reports
- LigaSure LF1937Covidien LP · Electrosurgical, cutting & coagulation & accessories3 deaths2,090 reports
- Olympus WB91051WOLYMPUS Winter & Ibe GmbH · Electrosurgical, Cutting & Coagulation & Accessories1 death1,951 reports
- Valleylab FT10 VLFT10GENCovidien LP · Electrosurgical, cutting & coagulation & accessories1 recall5 deaths1,062 reports
- LigaSure LF1837Covidien LP · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES1 recall967 reports
- LigaSure LF2019Covidien LP · Electrosurgical, cutting & coagulation & accessories948 reports
- VAPR 225028Depuy Mitek, LLC · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES895 reports
- LigaSure LF1923Covidien LP · Electrosurgical, cutting & coagulation & accessories855 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page