Edge E1450XRecalls & reported problems
Covidien LP · Hex-locking Blade Electrode · Class 2
All models of Edge (43)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 12
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 12 adverse event reports that list this exact device (DI 10884521713154), received between Oct 1, 2018 and May 16, 2025 — classified as 12 malfunctions.
The most frequently reported specific device problem is “Fire” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Fire5
- Melted5
- Peeled/Delaminated5
- Overheating of Device4
- Arcing2
- Adverse Event Without Identified Device or Use Problem1
- Detachment of Device or Device Component1
Patient problems
- No Clinical Signs, Symptoms or Conditions10
- Insufficient Information1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 12 most recent of 12 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 16, 2025Fire; Arcing; Fire; Arcing
ACCORDING TO THE REPORTER, DURING A BELOW KNEE AMPUTATION PROCEDURE, THE TIP "LIT UP LIKE A CANDLE". TIP WAS REPLACED AND THE PENCIL WORKED FINE. LATER THE SAME CASE, ANOTHER PENCIL WAS USED AND THE TIP SPARKED AND "BURNED LIKE CANDLE" AGAIN. THEY USED NEW DEVICE TO COMPLETE THE PROCEDURE. THERE WAS NO OPERATING ROOM FIRE AND IT EXTINGUISHED ON ITS OWN. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22035886 ↗MalfunctionMay 16, 2025Fire; Fire
ACCORDING TO THE REPORTER, DURING A BELOW KNEE AMPUTATION PROCEDURE, THE TIP "LIT UP LIKE A CANDLE". TIP WAS REPLACED AND THE PENCIL WORKED FINE. LATER THE SAME CASE, ANOTHER PENCIL WAS USED AND THE TIP SPARKED AND "BURNED LIKE CANDLE" AGAIN. THEY USED NEW DEVICE TO COMPLETE THE PROCEDURE. THERE WAS NO OPERATING ROOM FIRE AND IT EXTINGUISHED ON ITS OWN. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22035480 ↗MalfunctionApr 28, 2025Melted; Overheating of Device; Peeled/Delaminated; Melted; Overheating of Device; Peeled/Delaminated
ACCORDING TO THE REPORTER, DURING PROCEDURE, THE CAUTERY'S TIPS WERE VISIBLY MELTED/CHARRED FROM APPARENT EXTREME HEAT. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21919667 ↗MalfunctionApr 28, 2025Melted; Overheating of Device; Peeled/Delaminated; Melted; Overheating of Device; Peeled/Delaminated
ACCORDING TO THE REPORTER, DURING PROCEDURE, THE CAUTERY'S TIPS WERE VISIBLY MELTED/CHARRED FROM APPARENT EXTREME HEAT. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21919593 ↗MalfunctionApr 28, 2025Melted; Overheating of Device; Peeled/Delaminated; Melted; Overheating of Device; Peeled/Delaminated
ACCORDING TO THE REPORTER, DURING PROCEDURE, THE CAUTERY'S TIPS WERE VISIBLY MELTED/CHARRED FROM APPARENT EXTREME HEAT. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21919457 ↗MalfunctionApr 28, 2025Melted; Overheating of Device; Peeled/Delaminated; Melted; Overheating of Device; Peeled/Delaminated
ACCORDING TO THE REPORTER, THE CAUTERY'S TIPS WERE VISIBLY MELTED/CHARRED FROM APPARENT EXTREME HEAT. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21919405 ↗MalfunctionJan 2, 2024Peeled/Delaminated; Peeled/Delaminated
ACCORDING TO THE REPORTER, DURING LAPAROSCOPIC ILEAL RESECTION, WHILE OPERATING INSIDE THE ABDOMINAL CAVITY WITH A SMALL INCISION FOR ADHESION DISSECTION, A BLUE FRAGMENT WAS SEEN INSIDE THE ABDOMINAL CAVITY. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18432299 ↗MalfunctionMay 1, 2023Fire; Arcing; Fire; Arcing
ACCORDING TO THE REPORTER, DURING A REVISION KNEE PROCEDURE, THE DEVICE WAS USED SEVERAL TIMES AND WHILE IN THE KNEE, IT STARTED TO SPARK. IT WAS WITHDRAWN FROM THE KNEE AND THE DEVICE WAS IMMEDIATELY CAUGHT ON A SMALL FIRE/FLAME BUT IT WENT OUT ON ITS OWN. THE FIRE OCCURRED AT THE END OF THE BOVIE TIP AND WAS AWAY FROM THE PATIENT. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16845060 ↗MalfunctionFeb 16, 2023Fire; Fire
ACCORDING TO THE REPORTER, PRIOR TO USE, A SURGICAL FIRE IGNITED ON THE TIP OF THE ELECTRODE WITH THE SIZE OF SMALL MATCH STICK. THE ELECTRODE WAS THE ONE THAT COMES IN THE PENCIL. IT WAS EXTINGUISHED BY ITS OWN. THE STAFF KEPT THE PENCIL AND THE GENERATOR, CHANGED THE ELECTRODE AND CONTINUED THE PROCEDURE WITHOUT ANY OTHER INSTANCES OCCURRING. THERE LOOKS LIKE THERE IS WHITE ON THE ELECTRODE, ON BOTH SIDES. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16386531 ↗MalfunctionMar 16, 2021Melted; Adverse Event Without Identified Device or Use Problem; Melted; Adverse Event Without Identified Device or Use Problem
ACCORDING TO THE REPORTER, DURING FREON LAPAROSCOPIC, THE PROCEDURE WAS CONVERTED TO OPEN BUT NOT DUE TO THE ELECTRODE THAT LOOKED CHARRED AT TIP. THEY OPENED A NEW ELECTRODE TO COMPLETE PROCEDURE. THE PHOTO ATTACHED SHOWED THAT THE ELECTRODE TIP WAS MELTED.
Patient problems: Insufficient Information
MAUDE report 11494829 ↗MalfunctionFeb 5, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
ACCORDING TO THE REPORTER, DURING PROCEDURE, THE BURNING AT THE ELECTRODE REGION WAS SEVERE, SO THE PHYSICIAN HAD AN IMPRESSION THAT THE TIP WAS MISSING AND THE NURSE REQUESTED AN INVESTIGATION. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11284991 ↗MalfunctionOct 1, 2018Fire; Fire
ACCORDING TO THE REPORTER, DURING THE PROCEDURE, WHILE USING THE DEVICE THE TIP OF IT STARTED ON FIRE. THE SURGEON IMMEDIATELY STOPPED USING THE DEVICE AND THE FIRE WENT OUT. THE FIRE DID NOT AFFECT PATIENT TISSUE. THERE WAS NO PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7922814 ↗
Other ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES devices
- Vasoview Hemopro 2 VH-4000Maquet Cardiovascular LLC · Electrosurgical, Cutting & Coagulation & Accessories6 recalls1 death3,232 reports
- LigaSure LF1937Covidien LP · Electrosurgical, cutting & coagulation & accessories3 deaths2,090 reports
- Olympus WB91051WOLYMPUS Winter & Ibe GmbH · Electrosurgical, Cutting & Coagulation & Accessories1 death1,951 reports
- Valleylab FT10 VLFT10GENCovidien LP · Electrosurgical, cutting & coagulation & accessories1 recall5 deaths1,062 reports
- LigaSure LF1837Covidien LP · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES1 recall967 reports
- LigaSure LF2019Covidien LP · Electrosurgical, cutting & coagulation & accessories948 reports
- VAPR 225028Depuy Mitek, LLC · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES895 reports
- LigaSure LF1923Covidien LP · Electrosurgical, cutting & coagulation & accessories855 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page