LigaSure LF1930TRecalls & reported problems

Covidien LP · Maryland Jaw Thoracic Sealer/Divider Coated · Class 2

All models of LigaSure (32)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Quick summary

This Covidien LigaSure Maryland Jaw thoracic sealer/divider is a hand-held electrosurgical instrument that cuts and seals tissue during surgery. The 36 reports mostly describe energy output problems, jaws that won't open or close, and cutting failures; some mention bleeding or tissue injury. There are 3 reports of injuries and no deaths. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
38
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 38 adverse event reports that list this exact device (DI 10884521751040), received between Jun 29, 2018 and Sep 30, 2026 — classified as 3 injuries, 35 malfunctions.

The most frequently reported specific device problem is “Energy Output Problem” (16 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 3 reportsOct 2024: 1 reportsNov 2024: 1 reportsDec 2024: 2 reportsJan 2025: 2 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 2 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 2 reportsDec 2025: 2 reportsJan 2026: 1 reportsFeb 2026: 1 reportsMar 2026: 2 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 2 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Energy Output Problem16
  • Difficult to Open or Close10
  • Communication or Transmission Problem4
  • Detachment of Device or Device Component4
  • Failure to Cut4
  • Intermittent Energy Output4
  • Self-Activation or Keying4
  • Peeled/Delaminated2

Patient problems

  • No Clinical Signs, Symptoms or Conditions30
  • Insufficient Information4
  • Hemorrhage/Blood Loss/Bleeding2
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Blood Loss1
  • No Consequences Or Impact To Patient1
  • Unspecified Tissue Injury1

Recent adverse event reports

The 25 most recent of 38 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 30, 2026Unintended Power Up

    It was reported that prior to use, the device was unintentionally activated. A new device was successfully used. No patient was involved.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50941709 ↗
  • MalfunctionSep 28, 2026Energy Output Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50926379 ↗
  • MalfunctionMar 23, 2026Energy Output Problem

    ACCORDING TO THE REPORTER DURING A TOTAL LAPAROSCOPIC HYSTERECTOMY (TLH) PROCEDURE, DURING CERVICAL INCISION WHEN THE GENERATOR WAS TURNED ON, THE E236 ERROR CODE APPEARED. THE GENERATOR WAS RESTARTED AND THE ERROR MESSAGE DISAPPEARED, SO THIS PRODUCT (LF1930T) WAS CONNECTED AND USED, BUT THE SEAL TIME WAS CLEARLY SHORT AND THE SEAL WAS INSUFFICIENT. SEALING WAS INSUFFICIENT/PARTIAL ONLY (ENERGY OUTPUT AND SEAL COMPLETION SOUND WERE CONFIRMED). GENERATOR WAS RESTARTED AND REPLACED WITH ANOTHER NEW GENERATOR AND IT COULD BE USED WITHOUT ANY PROBLEMS. THE JAW PART WAS A LITTLE DIRTY AND WAS CLEANED EVERY TIME IT GOT DIRTY. ANOTHER LIGASURE WAS USED WITH THE SAME GENERATOR AND IT WORKED FINE. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24665297 ↗
  • MalfunctionMar 3, 2026Difficult to Open or Close; Intermittent Energy Output

    IT WAS REPORTED THAT IN THE MIDDLE OF A SPLENOPANCREATECTOMY PROCEDURE USING THE DEVICE, THE DEVICE JAW COULD NOT BE OPENED PROPERLY AFTER SEVERAL TIMES OF USE. THE DEVICE WAS PLUGGED INTO A GENERATOR AT THE TIME OF THE EVENT. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24499912 ↗
  • MalfunctionFeb 23, 2026Communication or Transmission Problem; Difficult to Open or Close

    IT WAS REPORTED THAT DURING A PROCEDURE INVOLVING THE USE OF THE DEVICE, THE HANDLE BECAME NON-RETURNABLE AFTER USE, AND THE BUTTON WAS NOT FUNCTIONING. THE DEVICE WAS PLUGGED INTO A GENERATOR WITH SOFTWARE VERSION 4.0.4, AND ANOTHER DEVICE WAS USED SUCCESSFULLY WITH THE SAME GENERATOR. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24415168 ↗
  • MalfunctionJan 16, 2026Unintended Power Up

    IT WAS REPORTED THAT THE DEVICE ACTIVATED WHEN UNINTENDED. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24094619 ↗
  • MalfunctionDec 8, 2025Communication or Transmission Problem; Detachment of Device or Device Component; Communication or Transmission Problem; Detachment of Device or Device Component

    IT WAS REPORTED THAT THE DEVICE EXPERIENCED A BUTTON MALFUNCTION. THERE WAS NO PATIENT INVOLVED. MEDTRONIC'S INITIAL EVALUATION OF THE INCIDENT DEVICE FOUND THE POST CLOSEST TO THE ACTIVATION BUTTON WAS BROKEN OFF.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23743495 ↗
  • MalfunctionDec 8, 2025Communication or Transmission Problem; Detachment of Device or Device Component; Communication or Transmission Problem; Detachment of Device or Device Component

    IT WAS REPORTED THAT THE DEVICE WAS ASSOCIATED WITH AN ISSUE IN WHICH THE BUTTON WAS NOT PRESSED. THERE WAS NO PATIENT INVOLVED. MEDTRONIC'S INITIAL EVALUATION OF THE INCIDENT DEVICE FOUND THE POST CLOSEST TO THE ACTIVATION BUTTON WAS BROKEN OFF.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23743398 ↗
  • MalfunctionNov 11, 2025Device Remains Activated; Communication or Transmission Problem; Device Remains Activated; Communication or Transmission Problem

    ACCORDING TO THE REPORTER DURING A PROCEDURE, THE BUTTON GOT STUCK SO IT WAS UNUSABLE.

    Patient problems: Insufficient Information

    MAUDE report 23521111 ↗
  • MalfunctionNov 10, 2025Energy Output Problem; Energy Output Problem

    IT WAS REPORTED THAT DURING SEGMENTECTOMY, THE HANDPIECE HAD NO SEAL. THERE WAS NO EVIDENCE OF ENERGY DELIVERY AND END TONES HEARD. THE SURGERY WAS COMPLETED WITHOUT ANY PROBLEMS AFTER USING THE NEW DEVICE.

    Patient problems: Insufficient Information

    MAUDE report 23512235 ↗
  • MalfunctionAug 17, 2025Energy Output Problem; Failure to Cut; Energy Output Problem; Failure to Cut

    IT WAS REPORTED THAT DURING THE PROCEDURE; THE DEVICE SEALING WAS NOT GOOD. IT WAS ALSO REPORTED THAT THERE HAD BEEN A CUTTING OR KNIFE BLADE ISSUE. A NEW HANDPIECE WAS USED WITH THE SAME GENERATOR AND IT WORKED FINE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22824343 ↗
  • MalfunctionAug 7, 2025Energy Output Problem; Failure to Cut; Energy Output Problem; Failure to Cut

    ACCORDING TO THE REPORTER, DURING A PROCEDURE, THE HANDPIECE PRESENTED A DEFECT WHERE IT SHOWED NO CAPABILITY TO SEAL AND CUT. SEVERAL ATTEMPTS WERE MADE BUT WITHOUT SUCCESS. REPLACEMENT OF THE HANDPIECE WAS NECESSARY TO CONTINUE THE PROCEDURE.

    Patient problems: Insufficient Information

    MAUDE report 22737344 ↗
  • MalfunctionJul 22, 2025Energy Output Problem; Failure to Cut; Energy Output Problem; Failure to Cut

    IT WAS REPORTED THAT DURING A PROCEDURE, THE HANDPIECE HAD NO SEAL AND WAS NOT CUTTING SUFFICIENTLY. A NEW HANDPIECE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO BLEEDING AND THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22563318 ↗
  • MalfunctionMay 23, 2025Energy Output Problem; Energy Output Problem

    IT WAS REPORTED THAT DURING A PROCEDURE, THE DEVICE CUT BUT DID NOT SEAL THE TISSUE. SEVERAL ATTEMPTS TO ACTIVATE IT WERE UNSUCCESSFUL. ANOTHER LIGASURE DEVICE WAS USED SUCCESSFULLY WITH THE SAME GENERATOR. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22075875 ↗
  • MalfunctionFeb 18, 2025Self-Activation or Keying; Self-Activation or Keying

    ACCORDING TO THE REPORTER PRIOR TO USE, THE DEVICE HAD ACTIVATED WHEN UNINTENDED. IT ACTIVATED WITHOUT THE ACTIVATION BUTTON BEING PUSHED. THE DEVICE DID NOT WORK FROM THE START AND WAS REPLACED WITH A NEW ONE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21397091 ↗
  • MalfunctionJan 15, 2025Difficult to Open or Close; Difficult to Open or Close

    ACCORDING TO THE REPORTER, AT THE END OF TOTAL LAPAROSCOPIC HYSTERECTOMY (TLH), THE DEVICE¿S JAW COULD NOT BE OPENED WHEN ATTACHED TO THE VAGINAL STUMP INCISION. THE SURGEON FORCIBLY OPENED THE JAW TO REMOVE FROM THE TISSUE. ANOTHER DEVICE WAS USED WITH THE SAME GENERATOR. CLEANING WAS PERFORMED WHEN THE DEVICE WAS RETURNED TO THE NURSE. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21158378 ↗
  • MalfunctionJan 8, 2025Self-Activation or Keying; Self-Activation or Keying

    ACCORDING TO THE REPORTER, DEVICE ACTIVATED WHEN UNINTENDED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21103361 ↗
  • MalfunctionDec 13, 2024Energy Output Problem; Intermittent Energy Output; Energy Output Problem; Intermittent Energy Output

    ACCORDING TO THE REPORTER, DURING THORACOSCOPIC LOBECTOMY PROCEDURE, THE DEVICE SEALING WAS INSUFFICIENT/PARTIAL (ENERGY OUTPUT AND SEAL COMPLETION SOUND WERE CONFIRMED). THERE WAS NO RE-GRASP ALERT OCCURRED. THE HANDPIECE WERE ABLE TO COMPLETE MULTIPLE GOOD SEALS BEFORE THE ISSUE OCCURRED. THEY CLEANED THE JAWS EACH TIME IT BECAME DIRTY. THE DEVICE WAS CONNECTED TO THE GENERATOR AND WAS REPLACED BY ANOTHER DEVICE, AND IT WORKED FINE. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20924365 ↗
  • MalfunctionDec 10, 2024Device Alarm System; Energy Output Problem; Device Alarm System; Energy Output Problem

    ACCORDING TO THE REPORTER, DURING TOTAL VAGINAL HYSTERECTOMY, WHEN SEALING THE SACRAL UTERINE LIGAMENT ABOUT 2-3MM, SEALING WAS INSU FFICIENT/PARTIAL SEALING (ENERGY OUTPUT AND SEALING COMPLETION SOUND COULD BE CONFIRMED). THERE WAS RE-GRASP ALERT. WHEN THE SEALING WAS PERFORMED TWICE, IT FELT THAT THE SEALING WAS WEAKER THAN USUAL, SO THE PRODUCT WAS REPLACED WITH A NEW ONE. AFTER THAT, THE DE VICE COULD BE USED WITHOUT ANY PROBLEMS. THE JAW REGION WAS A LITTLE DIRTY, AND CLEANED THE AREA AROUND THE JAW EVERY TIME IT GOT DIRTY. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20895334 ↗
  • MalfunctionNov 14, 2024Self-Activation or Keying; Self-Activation or Keying

    ACCORDING TO THE REPORTER, THE DEVICE ACTIVATED WHEN UNINTENDED. REPLACED WITH ANOTHER DEVICE, AND IT WORKED FINE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20684221 ↗
  • MalfunctionOct 29, 2024Difficult to Open or Close; Difficult to Open or Close

    ACCORDING TO THE REPORTER, PRIOR TO USE, THE DEVICE JAW WAS DIFFICULT/IMPOSSIBLE TO OPEN. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20558325 ↗
  • MalfunctionSep 17, 2024Break; Retraction Problem; Difficult to Open or Close; Intermittent Energy Output; Break; Retraction Problem; Difficult to Open or Close; Intermittent Energy Output

    ACCORDING TO THE REPORTER, DURING LAPAROSCOPIC VAGINAL TOTAL HYSTERECTOMY, DURING LIGAMENT TREATMENT, AT FIRST, IT COULD BE USED WIT HOUT ANY PROBLEMS, THEN THE JAW STOPPED OPENING AND CLOSING FROM MIDWAY; WHEN CHECKED, THE KNIFE SLIPPED OFF THE RAIL (NOT FROM THE BEGINNING, BUT DURING USE). THE KNIFE BLADE CANNOT BE RETRACTED. WHEN THE TRIGGER/BLADE LOCK WAS PULLED, IT WAS STUCK AND DID NOT RETURN. THE SHAPE OF THE KNIFE WAS JUDGED WITHIN THE RANGE THAT IT COULD BE OBSERVED. ANOTHER DEVICE WAS USED WITH THE SAME GENERATOR AND IT WORKED FINE. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20238332 ↗
  • MalfunctionSep 16, 2024

    THE LIGATURE WOULD NOT COMPLETE CYCLE OF DISSECTION. WE UNPLUGGED INSTRUMENT & PLUGGED IN TO TROUBLE SHOOT, CLEANED OFF TIPS, DEVICE PLUGGED INTO VALLEYLAB FORCE T10.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20223712 ↗
  • MalfunctionSep 4, 2024Difficult to Open or Close; Scratched Material; Difficult to Open or Close; Scratched Material

    ACCORDING TO THE REPORTER, DURING PROCEDURE, THE JAWS COULD NOT BE OPENED. CLEANING OF THE DEVICE WAS PERFORMED WHEN THERE WAS ADHESION ON THE JAW. THEREFORE, A NEW PRODUCT WAS USED. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20137757 ↗
  • MalfunctionJun 26, 2024Energy Output Problem; Energy Output Problem

    ACCORDING TO THE REPORTER, DURING A PROCEDURE, UNIT DID NOT SEAL WELL. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19620995 ↗

Other Electrosurgical, cutting & coagulation & accessories devices

All Electrosurgical, cutting & coagulation & accessories devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page