Valleylab Force Argon II-8Recalls & reported problems

Covidien LP · Argon Gas Delivery Unit II,240 V · Class 2

All models of Valleylab (97)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10884524002569), received between Mar 5, 2024 and Mar 5, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Inappropriate/Inadequate Shock/Stimulation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Inappropriate/Inadequate Shock/Stimulation1
  • No Apparent Adverse Event1

Patient problems

  • Burn(s)1
  • Electric Shock1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 5, 2024Inappropriate/Inadequate Shock/Stimulation; Adverse Event Without Identified Device or Use Problem; No Apparent Adverse Event; Inappropriate/Inadequate Shock/Stimulation; Adverse Event Without Identified Device or Use Problem; No Apparent Adverse Event

    ACCORDING TO THE REPORTER, THE MACHINE WAS BEING USED WITH A FORCETRIAD. THE NURSE RECEIVED AN ELECTRIC SHOCK AND BURN AT FRONT OF FORCETRIAD IN USE WITH A FORCE ARGON. WHEN CONNECTING E3520H LEAD TO UFP (UNIVERSAL FOOT PEDAL) PENCIL ACTIVATED BY SCRUB NURSE. THE NURSE HAD CONTACT WITH EXPOSED METAL TERMINAL ON COVIDIEN VALLYLAB ARGON HANDSET E3520H. THE BURN WAS MINOR, AND SIZE AND LOCATION OF BURN SITE WAS IN THUMB <(>&<)> INDEX FINGER. NURSE WAS CHECKED IN ED (EMERGENCY DEPARTMENT) AND KEPT UNDER OBS.

    Patient problems: Burn(s); Electric Shock

    MAUDE report 18842601 ↗