LigaSure LF1212A (UDI 20884521186030)Recalls & reported problems
Covidien LP · Curved, Small Jaw, Open Sealer/Divider · Class 2
All models of LigaSure (32)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 20884521186030), received between Nov 30, 2017 and Oct 26, 2021 — classified as 2 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Device Displays Incorrect Message” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Device Displays Incorrect Message1
- Device Stops Intermittently1
- Energy Output Problem1
- Energy Output To Patient Tissue Incorrect1
- Intermittent Energy Output1
Patient problems
- Blood Loss1
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
- Unspecified Infection1
- Unspecified Tissue Injury1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 26, 2021Energy Output Problem; Intermittent Energy Output; Energy Output Problem; Intermittent Energy Output
ACCORDING TO THE REPORTER, DURING ENLARGED TOTAL THYROIDECTOMY, THE DEVICE HAD PARTIAL SEAL. REGRASP ALERT WAS OBSERVED AND AN END TONE WAS HEARD. THERE WAS NO EVIDENCE OF ENERGY DELIVERY. THE DOCTOR USED TWO LIGASURE DEVICES, AS THE FIRST ONE WAS IN THE HEAD KIT AND NECK FAILURE. THE DEVICE WOULD NOT WORK CORRECTLY, THE FUNCTIONS WAS INTERMITTENT. THE SECOND DEVICE WORKED SUCCESSFULLY. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12695088 ↗InjuryJan 29, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ACCORDING TO THE LITERATURE, A RETROSPECTIVE STUDY COMPARED HYSTERECTOMIES PERFORMED WITH TRADITIONAL CUTTING AND TYING TOOLS AND TH OSE PERFORMED WITH LIGASURE INSTRUMENTS IN PATIENTS WITH KNOWN WITH PLACENTAL INSERTION ANOMALIES BETWEEN 2013 AND 2019. THERE WERE 28 PATIENTS IN THE LIGASURE GROUP AND POST-OPERATIVE COMPLICATIONS INCLUDED: TRANSFUSIONS, BLADDER REPAIR AND POST-OPERATIVE INFECTION. INTERVENTIONS FOR BLADDER REPAIR AND INFECTION NOT LISTED.
Patient problems: Unspecified Infection; Unspecified Tissue Injury
MAUDE report 11249965 ↗InjuryNov 13, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ACCORDING TO THE REPORTER, THE SURGEON USED THE DEVICE FOR A SALPINGO-OOPHORECTOMY ON A PATIENT WHO WAS POST-OPERATIVE C-SECTION. THE PATIENT HAD TO BE BROUGHT BACK TO THE OPERATING ROOM(OR) FOR RE-OPERATION DUE TO POST-OPERATIVE BLEEDING.
Patient problems: Blood Loss
MAUDE report 8065315 ↗MalfunctionNov 30, 2017Energy Output To Patient Tissue Incorrect; Device Stops Intermittently; Device Displays Incorrect Message; Energy Output To Patient Tissue Incorrect; Device Stops Intermittently; Device Displays Incorrect Message
ACCORDING TO THE REPORTER, DURING A PROCEDURE THE DEVICE WAS PRODUCING PARTIAL SEALS WITH NO RE-GRASP ALERTS. THERE WAS NO PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7072055 ↗
Other ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES devices
- Vasoview Hemopro 2 VH-4000Maquet Cardiovascular LLC · Electrosurgical, Cutting & Coagulation & Accessories6 recalls1 death3,232 reports
- LigaSure LF1937Covidien LP · Electrosurgical, cutting & coagulation & accessories3 deaths2,090 reports
- Olympus WB91051WOLYMPUS Winter & Ibe GmbH · Electrosurgical, Cutting & Coagulation & Accessories1 death1,951 reports
- Valleylab FT10 VLFT10GENCovidien LP · Electrosurgical, cutting & coagulation & accessories1 recall5 deaths1,062 reports
- LigaSure LF1837Covidien LP · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES1 recall967 reports
- LigaSure LF2019Covidien LP · Electrosurgical, cutting & coagulation & accessories948 reports
- VAPR 225028Depuy Mitek, LLC · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES895 reports
- LigaSure LF1923Covidien LP · Electrosurgical, cutting & coagulation & accessories855 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page