HelixAR 60-8800-001Recalls & reported problems
Conmed Corporation · HelixAR 100 - 240 VAC 50/60 Hz Electrosurgical Unit with Argon Beam Coagulator · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 30653405005531), received between Jun 26, 2024 and Jun 26, 2024 — classified as 1 malfunction.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Superficial (First Degree) Burn1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 26, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE CUSTOMER REPORTED THAT THE 60-8800-001, HELIXAR ESU, DEVICE WAS BEING USED DURING A CANALICULOPLASTY PROCEDURE ON (B)(6) 2024 WHEN IT WAS REPORTED ¿THE CIRCULATOR ATTACHED A THERMOGARD +ABC PAD TO THE PATIENT, IN ANTICIPATION FOR IF THE SURGEON WANTED TO USE ANY MONOPOLAR ENERGY, DESPITE HER SETTING UP THE HELIX FOR BIPOLAR USE. DURING THIS SET UP, THE NURSE ACCIDENTALLY PLUGGED IN THE TWO BIPOLAR PLUGS INTO THE ARGON HAND PIECE OUTLETS. WHEN THE SURGEON WENT TO ACTIVATE ENERGY, THE SURGEON REMEMBERS HEARING A ¿ZAP¿ SOUND AND THAT THEY BELIEVE THIS IS RELATED TO THE SUPERFICIAL BURN ON THE PATIENT THAT APPEARED FROM THIS CASE. THE BURN IS AROUND THE PATIENT¿S ORBITAL REGION. THEY ARE WANTING TO REPORT THIS AS A PATIENT BURN DUE TO THE HELIX ALBEIT SET UP INCORRECTLY AND THE NUMEROUS USER ERRORS (I.E., ARGON TANK SLIGHTLY BEING OPEN DESPITE WANTING BIPOLAR ENERGY, GROUNDING PAD STILL APPLIED EVEN THOUGH THEY WANTED BIPOLAR ENERGY, INCORRECTLY INSERTING BIPOLAR PLUGS INTO ARGON HANDPIECE OUTLETS).¿. FURTHER ASSESSMENT FOUND THAT "REPORT FROM THE PHYSICIAN, THE BURN IS HEALING WELL." THE DEGREE OF SUPERFICIAL BURN WAS NOT REPORTED IT IS UNKNOWN AND THE HAND PIECE WAS BELIEVED TO B
Patient problems: Superficial (First Degree) Burn
MAUDE report 19617666 ↗
Other Electrosurgical, cutting & coagulation & accessories devices
- Vasoview Hemopro 2 VH-4000Maquet Cardiovascular LLC · Electrosurgical, Cutting & Coagulation & Accessories6 recalls1 death3,232 reports
- LigaSure LF1937Covidien LP · Electrosurgical, cutting & coagulation & accessories3 deaths2,090 reports
- Olympus WB91051WOLYMPUS Winter & Ibe GmbH · Electrosurgical, Cutting & Coagulation & Accessories1 death1,951 reports
- Valleylab FT10 VLFT10GENCovidien LP · Electrosurgical, cutting & coagulation & accessories1 recall5 deaths1,062 reports
- LigaSure LF1837Covidien LP · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES1 recall967 reports
- LigaSure LF2019Covidien LP · Electrosurgical, cutting & coagulation & accessories948 reports
- VAPR 225028Depuy Mitek, LLC · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES895 reports
- LigaSure LF1923Covidien LP · Electrosurgical, cutting & coagulation & accessories855 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page