Skip to content

VIVACE ULTRA VERSION 1.0Recalls & reported problems

Aesthetics Biomedical, Inc. · ELECTROSURGICAL DEVICE WITHOUT ULTRASOUND MEANT FOR ELECTROCOAGULATION AND HEMOSTASIS IN DERMATOLOGIC SURGEY · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI G055ABMVIVS020), received between May 4, 2026 and May 4, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Use of Device Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Use of Device Problem1

Patient problems

  • Scar Tissue1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 4, 2026Use of Device Problem

    A PRACTICE CONTACTED AESTHETICS BIOMEDICAL (ABM) WITH AN IMAGE OF A PATIENT WITH HYPERTROPHIC SCARRING AND HEALING LESIONS ON THEIR ABDOMEN AFTER A RECENT ULTRAVISION TREATMENT. ABM'S CHIEF MEDICAL OFFICER (CMO) IMMEDIATELY INITIATED CONTACT WITH THE PRACTICE TO SPEAK WITH THE PRACTITIONER TO GAIN MORE KNOWLEDGE AND UNDERSTANDING ABOUT THE TREATMENT. THE CMO SPOKE WITH THE PRACTICE OWNER WHO PROVIDED INFORMATION THAT WAS CONTAINED IN THE PATIENT CHART. THE SETTINGS THAT WERE PROVIDED TO THE CMO INCLUDED POWER LEVCEL 8 (40 WATTS), 700 MS, 1 MHZ, 2 PASSES AT A DEPTH OF 3.9 MM WITH A 60-ARRAY INSULATED NEEDLE SET. THE TREATMENT PARAMETERS WERE NOT WITHIN ABM'S SUGGESTED TREATMENT GUIDELINES FOR THE TARGET TISSUE. THE CMO ATTEMPTED TO OBTAIN MORE INFORMATION, REQUESTING THAT SHE BE ABLE TO SPEAK WITH THE AESTHETICIAN WHO PERFORMED THE TREATMENT BUT WAS NOT GIVEN THE OPPORTUNITY.

    Patient problems: Scar Tissue

    MAUDE report 25073326 ↗

Other Electrosurgical, Cutting & Coagulation & Accessories devices

All Electrosurgical, Cutting & Coagulation & Accessories devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page