Mega SoftRecalls & reported problems across all models
Megadyne Medical Products, Inc. · 11 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
14 open recalls name at least one Mega Soft model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 145
- Deaths reported
- 0
- Injuries reported
- 86
- Recalls
- 14
We found 11 models of Mega Soft by Megadyne Medical Products, Inc. in the FDA's device registry (GUDID). Together they are named in 145 adverse event reports in the FDA's MAUDE database, received between Oct 24, 2018 and Aug 19, 2026 — classified as 86 injuries, 59 malfunctions.
The most frequently reported specific device problem is “Arcing of Electrodes” (27 reports).
14 FDA recall records name at least one of these models by its device identifier, 14 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Mega Soft recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Jun 17, 2024Open, Classified
To limit the use of the Mega Soft Pads to patients aged 12 or older to mitigate the potential risk of patient burns identified with use of Mega Soft pads.
Z-2250-2024 · Root cause: Unknown/Undetermined by firm · Recall details · FDA record ↗
- Jun 17, 2024Open, Classified
To limit the use of the Mega Soft Pads to patients aged 12 or older to mitigate the potential risk of patient burns identified with use of Mega Soft pads.
Z-2249-2024 · Root cause: Unknown/Undetermined by firm · Recall details · FDA record ↗
- May 8, 2024Open, Classified
Reports of patient burns.
Z-1920-2024 · Root cause: Device Design · Recall details · FDA record ↗
- Dec 8, 2023Open, Classified
Affected product codes are now limited to use in patients age 12 years or older. Megadyne has received reports of patient burn injuries up to and including third-degree burns requiring intervention which may lead to prolonged hospital stay, scarring, and additional surgeries in both pediatric and adult patients.
Z-0600-2024 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- Dec 8, 2023Open, Classified
Affected product codes are now limited to use in patients age 12 years or older. Megadyne has received reports of patient burn injuries up to and including third-degree burns requiring intervention which may lead to prolonged hospital stay, scarring, and additional surgeries in both pediatric and adult patients.
Z-0599-2024 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- Dec 8, 2023Open, Classified
Affected product codes are now limited to use in patients age 12 years or older. Megadyne has received reports of patient burn injuries up to and including third-degree burns requiring intervention which may lead to prolonged hospital stay, scarring, and additional surgeries in both pediatric and adult patients.
Z-0598-2024 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- Dec 8, 2023Open, Classified
Affected product codes are now limited to use in patients age 12 years or older. Megadyne has received reports of patient burn injuries up to and including third-degree burns requiring intervention which may lead to prolonged hospital stay, scarring, and additional surgeries in both pediatric and adult patients.
Z-0597-2024 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- Jun 1, 2023Open, Classified
Firm has received reports of patient burns in surgical procedures where device was used.
Z-2001-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- Jun 1, 2023Open, Classified
Firm has received reports of patient burns in surgical procedures where device was used.
Z-2000-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- Jun 1, 2023Open, Classified
Firm has received reports of patient burns in surgical procedures where device was used.
Z-1999-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- Jun 1, 2023Open, Classified
Firm has received reports of patient burns in surgical procedures where device was used.
Z-1998-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- Jun 1, 2023Open, Classified
Firm has received reports of patient burns in surgical procedures where device was used.
Z-1997-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- Jun 1, 2023Open, Classified
Firm has received reports of patient burns in surgical procedures where device was used.
Z-1996-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
- Jun 1, 2023Open, Classified
Firm has received reports of patient burns in surgical procedures where device was used.
Z-1995-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported Mega Soft problems
Device problems
- Adverse Event Without Identified Device or Use Problem97
- Arcing of Electrodes27
- Appropriate Device Problem Term/Code Not Available20
- Human-Device Interface Problem14
- Material Integrity Problem14
- Patient Device Interaction Problem8
- Unintended Electrical Shock6
- Scratched Material3
Patient problems
- Partial thickness (Second Degree) Burn71
- Full thickness (Third Degree) Burn31
- Burn(s)28
- No Clinical Signs, Symptoms or Conditions28
- Blister10
- No Consequences Or Impact To Patient10
- Scar Tissue9
- Pain8
Mega Soft models
11 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Mega Soft 0845ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES2 recalls72 reports
- Mega Soft 0846ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES2 recalls23 reports
- Mega Soft 0848Electrosurgical, cutting & coagulation & accessories2 recalls11 reports
- Mega Soft 0847Electrosurgical, cutting & coagulation & accessories2 recalls10 reports
- Mega Soft 0830ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES2 recalls9 reports
- Mega Soft 0840ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES2 recalls5 reports
- Mega Soft 0835ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES2 recalls4 reports
- Mega Soft M2K07Electrosurgical, cutting & coagulation & accessories7 reports
- Mega Soft M2K09Electrosurgical, cutting & coagulation & accessories2 reports
- Mega Soft M2K01Electrosurgical, cutting & coagulation & accessories1 report
- Mega Soft M2K02Electrosurgical, cutting & coagulation & accessories1 report
Recent Mega Soft adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
InjuryAug 19, 2026Adverse Event Without Identified Device or Use Problem
Patient problems: Burn(s)
MAUDE report 50329900 ↗InjuryJul 27, 2026Adverse Event Without Identified Device or Use Problem
It was reported that during a C-Section there was an occurrence of a patient burn during a surgical procedure due to insulation and the presence of the pad under the patient.
Patient problems: Partial thickness (Second Degree) Burn
MAUDE report 50038395 ↗InjuryMar 30, 2026Arcing of Electrodes; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THEY WERE PERFORMING A PACEMAKER SURGERY ON A PATIENT WHEN A FIRE STARTED, CAUSING BURNS TO THE PATIENT.
Patient problems: Burn(s)
MAUDE report 24727750 ↗MalfunctionJan 30, 2026Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information
IT WAS REPORTED THAT THE BURN SUFFERED BY CANINE (BACK, BETWEEN SHOULDER BLADES) DURING TPLO SURGERY BECAUSE OF ASSUMED USE OF MEGA SOFT PAD. VETERINARIAN MENTIONED THAT SHE SUSPECTED BURN IS DUE TO THE USE OF THE MEGA SOFT PAD DURING THE PROCEDURE BECAUSE OF THE PRESENTATION AND LOCATION OF THE BURN AND AWARENESS OF RECALL AND ISSUES WITH THE PAD - BUT COULD NOT CONFIRM OR DISPROVE USE OF THE MEGA SOFT PAD DURING THIS PARTICULAR PROCEDURE. CANINE IS STABLE AND BURN IS BEING TREATED.
Patient problems: Burn(s); No Clinical Signs, Symptoms or Conditions
MAUDE report 24225320 ↗MalfunctionNov 5, 2025Arcing of Electrodes; Arcing of Electrodes
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE THERE WAS SPARKING WITH THE MEGADYNE PAD WHILE IN USE. THERE WERE NO PATIENT CONSEQUENCES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23475621 ↗MalfunctionNov 5, 2025Arcing of Electrodes; Arcing of Electrodes
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE THERE WAS SPARKING WITH THE MEGADYNE PAD WHILE IN USE. THERE WERE NO PATIENT CONSEQUENCES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23475604 ↗InjuryAug 21, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING A NEPHRECTOMY THERE WAS A PATIENT BURN.
Patient problems: Partial thickness (Second Degree) Burn
MAUDE report 22860466 ↗InjuryAug 7, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE THE DOCTOR USED MEGA SOFT UNIVERSAL ELECTRODE AND AFTER THE SURGERY THE DOCTOR OBSERVED THE SKIN GOT SEVERED BURNED IN POSTERIOR SIDE OF PATIENT BODY.
Patient problems: Burn(s); Full thickness (Third Degree) Burn
MAUDE report 22742602 ↗MalfunctionAug 5, 2025Arcing of Electrodes; Arcing of Electrodes
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE THERE WAS SPARKING WITH THEIR MEGADYNE PAD WHILE IN USE. THERE WERE NO PATIENT CONSEQUENCES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22719521 ↗InjuryFeb 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE THERE WAS A PAD SITE BURN.
Patient problems: Blister; Burn(s)
MAUDE report 21374674 ↗MalfunctionFeb 10, 2025Arcing of Electrodes; Arcing of Electrodes
IT WAS REPORTED THAT DURING AN UNKNOWN WHILE USING AN ELECTROCAUTERY PENCIL, THE ELECTRICITY ARCED TO THE SURGEONS HAND HOLDING A LAPAROTOMY SPONGE. THE ARC CAUSED THE SPONGE TO LIGHT ON FIRE AND INITIALLY THE SURGEON THOUGHT HER GLOVE MAY HAVE HAD A HOLE BUT THERE WAS NO INDICATION OF A BURN OR INJURY TO HER FINGER. THE SURGEON BELIEVED THE MEGASOFT PAD TO BE THE CAUSE SO THEY CONTINUED THE CASE USING A STICKY PAD AND HAD NO FURTHER ISSUES. UPON INSPECTION, THE MEGASOFT PAD DID NOT APPEAR TO HAVE ANY DAMAGE, BURNS, OR OTHER ISSUES AND THE PATIENT DID NOT SUFFER ANY INJURIES EITHER. THE SURGERY WAS DELAYED 15 MINUTES. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WERE NO PATIENT CONSEQUENCES. FIRE WAS PUT OUT AND A STICKY PAD WAS USED.,
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21343128 ↗InjuryNov 14, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING AN ORTHOPEDIC PROCEDURE THE PATIENT SUFFERED A BURN ON THEIR LOWER LEG POSTERIOR. WHILE THE REP WAS DISCUSSING THE IFU CHANGE AT THE ACCOUNT THE ACCOUNT MENTIONED THIS ISSUE HAPPENED MONTHS AGO.
Patient problems: Full thickness (Third Degree) Burn
MAUDE report 20684412 ↗MalfunctionNov 11, 2024Arcing of Electrodes; Human-Device Interface Problem; Material Integrity Problem; Adverse Event Without Identified Device or Use Problem; Arcing of Electrodes; Human-Device Interface Problem; Material Integrity Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE FROM A VETERINARY THAT DURING AN OPERATION WITH THE MEGADYNE MAT, THE MAT EXPLODED AND CAUGHT FIRE. SMALL FLASHES ALL OVER THE MAT, WHICH THEN ENDED IN SEVERAL FLAMES. AFTER THE INCIDENT, YOU COULDN'T SEE WHAT HAD HAPPENED ON THE MAT. THE PATIENT WAS A SMALL YORKSHIRE TERRIER (APPROX. 3 KG). HE SUFFERED BURNS TO HIS STOMACH. THE MAT WAS CONNECTED TO AN MEGADYNE GENERATOR EXPIRATION DATE 30.09.2023.
Patient problems: Burn(s); Full thickness (Third Degree) Burn; Necrosis; Partial thickness (Second Degree) Burn; Scar Tissue
MAUDE report 20651317 ↗InjuryOct 29, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING A HIP SURGERY THE PATIENT GOT BURN WHEN MEGASOFT WAS USED ON THE OPPOSITE SIDE OF THE PATIENT ( PART OF BODY TOUCHES THE TABLE NOT THE SURGICAL AREA). .
Patient problems: Partial thickness (Second Degree) Burn
MAUDE report 20560236 ↗InjurySep 20, 2024Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem; Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE THE PATIENT SUFFERED A THIRD-DEGREE BURN. A SURGICAL INTERVENTION WAS REQUIRED. THE IMPACTED DEVICE WAS USED BY THE SURGEON WHEREAS IT WAS ALREADY EXPIRED (SINCE APRIL 2021).
Patient problems: Full thickness (Third Degree) Burn; Pain
MAUDE report 20266062 ↗
Other Megadyne Medical Products, Inc. products
All Megadyne Medical Products, Inc. devices →Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page