Mega Soft M2K02Recalls & reported problems
Megadyne Medical Products, Inc. · Mega Soft Standard Cable 4.4m (14'-4") · Class 2
All models of Mega Soft (11)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10614559105184), received between Feb 14, 2023 and Feb 14, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Arcing of Electrodes” (1 report).
8 other recalls cover devices cleared under the same FDA submission (K080741, K133726); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Arcing of Electrodes1
- Human-Device Interface Problem1
Patient problems
- Burn(s)1
- Partial thickness (Second Degree) Burn1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 14, 2023Arcing of Electrodes; Human-Device Interface Problem; Adverse Event Without Identified Device or Use Problem; Arcing of Electrodes; Human-Device Interface Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING A RESECTION OF SUBCUTANEOUS CELL TISSUE TUMOR IN THE POSTERIOR NECK THE PATIENT WAS IN THE FACE DOWN POSITION WITH OXYGEN CANNULA AND FACE MASK. THE PROCEDURE BEGAN AND THE ELECTIVE PENCIL GENERATED A SPARK, WHICH IS WHY ANOTHER PENCIL WAS REQUESTED, WHICH WHEN ACTIVATED GENERATED A FLAME OF FIRE ON THE PATIENT, CAUSING A BURN ON THE SKIN OF THE RIGHT CHEEKBONE OF THE PATIENT. THE FACE, BEHIND THE EAR AND THE HAIR. THE PERSONNEL CONTROL THE FIRE AND FINISH THE PROCEDURE WITH ANOTHER MEDTRONIC ELECTRO PENCIL AND THE VALLEYLAB CONSOLE. THE SURGERY WAS DELAYED 20 MINUTES. THE FLAMES WERE EXTINGUISHED, THE PATIENT WAS CLEANED AND THE PROCEDURE WAS FINISHED WITH A VALLEYLAB CONSOLE AND AN ELECTRO PEN FROM MEDTRONIC.
Patient problems: Burn(s); Partial thickness (Second Degree) Burn
MAUDE report 16375233 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K080741, K133726. One submission often covers many models, so check the product and lot details in each record.
- Z-2248-2024 · Jun 17, 2024 · Open, ClassifiedBrand Name: MEGADYNE" MEGA 2000" Patient Return Electrode Product Name: MEGADYNE" MEGA 2000" Patient Return Electrode Model/Catalog Number: 0800 Software Version: N/A Product Descr
- Z-1920-2024 · May 8, 2024 · Open, ClassifiedMEGADYNE MEGA SOFT Pediatric Patient Return Electrode. Reusable Patient Return Electrode for patients weighing (0.8lb-50lb), (350g-22.7Kg), 66cm Long x 30.5cm Wide x 1.25cm. Electr
- Z-0597-2024 · Dec 8, 2023 · Open, ClassifiedProduct Code 0845, MEGADYNE MEGA SOFT Universal Patient Return Electrode, Reusable Patient Return Electrode
- Z-2000-2023 · Jun 1, 2023 · Open, ClassifiedMEGADYNE MEGA SOFT Universal Plus Dual Patient Return Electrode. used during electrosurgery
- Z-1998-2023 · Jun 1, 2023 · Open, ClassifiedMEGADYNE MEGA SOFT Universal Patient Return Electrode. used during electrosurgery
- Z-1999-2023 · Jun 1, 2023 · Open, ClassifiedMEGADYNE MEGA SOFT Universal Plus Patient Return Electrode. used during electrosurgery
- Z-1997-2023 · Jun 1, 2023 · Open, ClassifiedMEGADYNE MEGA SOFT Pediatric Patient Return Electrode. used during electrosurgery
- Z-2001-2023 · Jun 1, 2023 · Open, ClassifiedMEGADYNE MEGA SOFT Universal Dual Patient Return Electrode. used during electrosurgery
Other Electrosurgical, cutting & coagulation & accessories devices
- Vasoview Hemopro 2 VH-4000Maquet Cardiovascular LLC · Electrosurgical, Cutting & Coagulation & Accessories6 recalls1 death3,232 reports
- LigaSure LF1937Covidien LP · Electrosurgical, cutting & coagulation & accessories3 deaths2,090 reports
- Olympus WB91051WOLYMPUS Winter & Ibe GmbH · Electrosurgical, Cutting & Coagulation & Accessories1 death1,951 reports
- Valleylab FT10 VLFT10GENCovidien LP · Electrosurgical, cutting & coagulation & accessories1 recall5 deaths1,062 reports
- LigaSure LF1837Covidien LP · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES1 recall967 reports
- LigaSure LF2019Covidien LP · Electrosurgical, cutting & coagulation & accessories948 reports
- VAPR 225028Depuy Mitek, LLC · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES895 reports
- LigaSure LF1923Covidien LP · Electrosurgical, cutting & coagulation & accessories855 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.