St. Jude Medical, Fixed Curve Response 6F Electrophysiology… recallZ-0177-2015 · St Jude Medical · initiated Oct 14, 2014
Class II Terminated All recalls posted in November 2014
Is my device affected?
- Compare the model, catalog and lot or serial numbers on your device or its packaging with the code information below. A recall usually covers only specific models or lots.
- If yours is listed, follow the instructions from St Jude Medical or your healthcare provider. The company's action is summarized under what the company is doing.
- Do not stop using a prescribed or implanted device on your own — talk to your healthcare provider first.
Where to find your model and lot numbers · What recall classes and statuses mean
Why it was recalled
St. Jude Medical is performing a voluntary recall of batch 4671318, model number 401353 of the Response Fixed Curve DECA 6F 65cm CSL 2/8 Catheter. Specifically, the firm has identified that every device packaged within batch 4671318 contains the incorrect catheter (Supreme FC QUAD 5F catheter) within the packaging. To date, no serious injuries have occurred as a result of this issue
FDA root cause category: Labeling mix-ups
What the company is doing
St. Jude Medical sent an "Urgent Medical Device Recall Notice" letter dated October 7, 2014, to all affected customers. The letter identified the product the problem and the action needed to be taken by the customer. Advised customers to discontinue the use of the recalled device and inform them that a St. Jude Medical sales representative will contact them in the near future to facilitate removal and reconciliation of the recalled device. For questions they can contact their St. Jude Medical Sales Representative. For further questions please call (651) 756-2295.
Recall details
- Recall number
- Z-0177-2015
- Recall class
- Class II
- Status
- Terminated
- Initiated by the company
- Oct 14, 2014
- Posted by the FDA
- Nov 6, 2014
- Recalling firm
- St Jude Medical
- Quantity
- 26
- Product code
- DRF
- FDA submissions
- K894500
- Distribution
- US Distribution including the states of CA, GA, NJ, NY, OR and PA.
Product description
St. Jude Medical, Fixed Curve Response 6F Electrophysiology Catheter, CSL, Model 401353
Code information (models, lots, serial numbers)
Batch # 4671318
Other devices under the same FDA submission
24 devices cleared under K894500 — the recall does not name any of them by identifier. One submission often covers many models, so they may or may not be affected.
- Supreme™ 401430St. Jude Medical Cardiovascular Division · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING8 reports
- Supreme™ 402004St. Jude Medical Cardiovascular Division · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 reports
- Response™ 401353St. Jude Medical Cardiovascular Division · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING4 reports
- Supreme™ 401443St. Jude Medical Cardiovascular Division · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING4 reports
- Supreme™ 401450St. Jude Medical Cardiovascular Division · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING4 reports
- Response™ 401227St. Jude Medical Cardiovascular Division · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING2 deaths3 reports
- Response™ 401261St. Jude Medical Cardiovascular Division · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING3 reports
- Supreme™ 401436St. Jude Medical Cardiovascular Division · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING3 reports
- Supreme™ 401442St. Jude Medical Cardiovascular Division · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 death3 reports
- Supreme™ 401449St. Jude Medical Cardiovascular Division · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING2 reports
- Supreme™ 401451St. Jude Medical Cardiovascular Division · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING2 reports
- Supreme™ 401860St. Jude Medical Cardiovascular Division · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING2 reports
Sources and updates
- Recall record: FDA Medical Device Recalls, file dated Oct 16, 2026 · View the FDA recall notice ↗
- Devices: FDA GUDID, file dated Oct 13, 2026. Devices are linked when their identifier (with a valid check digit) appears in the recall's code information.
- Page last rebuilt: Oct 18, 2026. Text above is shown as published by the FDA.
How recalls are matched to devices · Editorial policy · Report an error on this page