VivAer® Stylus FG722Recalls & reported problems
Aerin Medical Inc. · The VivAer® Stylus is a disposable handheld device capable of delivering bipolar radiofrequency energy to tissue. The VivAer® Stylus consists of a handle, shaft and treatment tip. An array of bipolar electrodes is positioned on a nonconductive tip which is attached to a handle via a nonconductive shaft. A temperature sensor is located on the tip to monitor tissue temperature. The Stylus is attached to a Temperature controlled radiofrequency generator (Aerin Console) via a flexible cable. · Class 2
All models of VivAer Stylus (2)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08886479300160), received between Aug 26, 2022 and Mar 5, 2025 — classified as 3 injuries.
1 other recall cover devices cleared under the same FDA submission (K200300); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
Patient problems
- Cartilage damage1
- Deformity/ Disfigurement1
- Epistaxis1
- Perforation1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryMar 5, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT PRESENTED WITH EXTERNAL NASAL VALVE COLLAPSE AND LOWER LATERAL CARTILAGE STENOSIS. THE PHYSICIAN TREATED THE LOWER LATERAL CARTILAGE AND ALAR CARTILAGE WITH THE VIVAER STYLUS AND REPORTED OVERLAPPING SOME TREATMENTS. THE PATIENT RETURNED FOR FOLLOW UP AFTER A PERIOD OF SEVERAL MONTHS WITH ABSORPTION OF A PORTION OF THE LOWER LATERAL CARTILAGE AND WORSENING OF THE EXTERNAL NASAL VALVE COLLAPSE. APPROXIMATELY 14 MONTHS LATER, A REVISION SURGERY WAS PERFORMED, OPEN VALVE NASAL RECONSTRUCTION. IT WAS ALSO REPORTED THAT THE PATIENT HAD TWO PREVIOUS NASAL SURGERIES INCLUDING A RHINOPLASTY. BASED ON THESE CIRCUMSTANCES, INTENTIONAL USE ERROR CAUSED AND CONTRIBUTED TO THE REPORTED EVENT. ADDITIONAL INFORMATION FROM THE PHYSICIAN STATES THEY ARE AWARE OF INDICATIONS FOR USE. AERIN MEDICAL WILL CONTINUE TO MONITOR AND TREND FOR REPORTS OF THIS NATURE.
Patient problems: Cartilage damage; Deformity/ Disfigurement
MAUDE report 21532491 ↗InjuryJan 10, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT RECEIVED VIVAER TREATMENT OF THE INFERIOR TURBINATES AND SWELL BODIES ON (B)(6) 2023. APPROXIMATELY 1 MONTH POST TREATMENT ((B)(6) 2023) THE PATIENT EXPERIENCED A SEVERE NOSEBLEED AND WENT TO THE EMERGENCY ROOM AND HAD EMBOLISM OF THE SPA DONE TO STOP THE BLEEDING AND SPENT 5 DAYS IN THE HOSPITAL. THE PATIENT REPORTED THAT THEY LOST NEARLY 2 PINTS OF BLOOD AND THAT SHE WAS RECOVERING BUT IN PAIN AND THEIR THROAT WAS IRRITATED FROM THE INTUBATION TUBE. APPROXIMATELY 1 WEEK LATER, THE PATIENT EXPERIENCED A SECOND NOSEBLEED AND RETURNED TO THE EMERGENCY ROOM. A CEREBRAL ANGIOGRAM WAS PERFORMED, AND THE PATIENT HAD EMBOLIZATION OF THE SPA REPEATED TO STOP THE BLEEDING. THE PATIENT IS RECOVERING.
Patient problems: Epistaxis
MAUDE report 18490156 ↗InjuryAug 26, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ON (B)(6) 2022, THE PATIENT WAS TREATED WITH THE VIVAER STYLUS ONLY ON THE RIGHT SIDE. THE SWELL BODY, INTERNAL NASAL VALVE AND THE INFERIOR TURBINATE WERE TREATED. PATIENT HAD FIRST FOLLOW UP VISIT ON (B)(6) 2022 AND AGAIN ON (B)(6) 2022. AT BOTH VISITS, THE PATIENT SHOWED GOOD MUCOSAL HEALING. AT THIRD FOLLOW-UP VISIT ON (B)(6) 2022, MUSCOSA WAS INTACT. PHYSICIAN DISCUSSED SEPTO-TURB OPTION WITH THE PATIENT BECAUSE PATIENT WAS STILL COMPLAINING OF CONGESTION. AT 7-MONTH FOLLOW-UP ON (B)(6) 2022, PATIENT PRESENTED WITH CRUSTING ON SEPTUM AND 1X1 CM2 MUCOSAL PERFORATION IN AREA TREATED WITH VIVAER STYLUS. CARTILAGE WAS INTACT. THE PATIENT REPORTED USING AFRIN OFF AND ON FOR PAST MONTH. PHYSICIAN PLANS TO MOVE FORWARD WITH SEPTOPLASTY PROCEDURE TO ADDRESS PERSISTENT CONGESTION. TOPICAL NASAL DECONGESTANT SPRAYS HAVE BEEN REPORTED TO CAUSE MUCOSAL PERFORATION. THE DETERIORATION OF THE MUCOSA IS PROBABLY RELATED TO THE COMBINATION OF THE RADIOFREQUENCY TREATMENT OF THE TISSUE IN THE AREA FOLLOWED BY USE OF AFRIN.
Patient problems: Perforation
MAUDE report 15307612 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K200300. One submission often covers many models, so check the product and lot details in each record.
- Z-0808-2025 · Nov 12, 2024 · Open, ClassifiedAerin Medical VivAer Stylus, REF CAT1785 (individual stylus), and REF CAT500 (5-pack), sterile.
Other Electrosurgical, Cutting & Coagulation & Accessories devices
- Vasoview Hemopro 2 VH-4000Maquet Cardiovascular LLC · Electrosurgical, Cutting & Coagulation & Accessories6 recalls1 death3,232 reports
- LigaSure LF1937Covidien LP · Electrosurgical, cutting & coagulation & accessories3 deaths2,090 reports
- Olympus WB91051WOLYMPUS Winter & Ibe GmbH · Electrosurgical, Cutting & Coagulation & Accessories1 death1,951 reports
- Valleylab FT10 VLFT10GENCovidien LP · Electrosurgical, cutting & coagulation & accessories1 recall5 deaths1,062 reports
- LigaSure LF1837Covidien LP · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES1 recall967 reports
- LigaSure LF2019Covidien LP · Electrosurgical, cutting & coagulation & accessories948 reports
- VAPR 225028Depuy Mitek, LLC · ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES895 reports
- LigaSure LF1923Covidien LP · Electrosurgical, cutting & coagulation & accessories855 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page