TARGET XLRecalls & reported problems across all models
Stryker Corporation · 34 models in the FDA device registry
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 369
- Deaths reported
- 1
- Injuries reported
- 107
- Recalls
- 0
We found 34 models of TARGET XL by Stryker Corporation in the FDA's device registry (GUDID). Together they are named in 369 adverse event reports in the FDA's MAUDE database, received between Jun 6, 2016 and Sep 23, 2026 — classified as 1 death, 107 injuries, 261 malfunctions.
The most frequently reported specific device problem is “Premature Separation” (177 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported TARGET XL problems
Device problems
- Premature Separation177
- Fracture59
- Adverse Event Without Identified Device or Use Problem47
- Premature Activation36
- Break33
- Migration or Expulsion of Device14
- Expulsion13
- Migration6
Patient problems
- No Clinical Signs, Symptoms or Conditions203
- No Consequences Or Impact To Patient97
- No Known Impact Or Consequence To Patient25
- Stroke/CVA11
- Device Embedded In Tissue or Plaque8
- Thrombosis7
- Thrombosis/Thrombus7
- Foreign Body In Patient6
TARGET XL models
34 models, most reported first. Each model has its own page with its reports, recalls and device details.
- TARGET XL M0036128300Device, Vascular, for Promoting Embolization1 death33 reports
- TARGET XL M0036121040Device, Vascular, for Promoting Embolization32 reports
- TARGET XL M0036126200Device, Vascular, for Promoting Embolization31 reports
- TARGET XL M0036125150DEVICE, NEUROVASCULAR EMBOLIZATION27 reports
- TARGET XL M0036124120DEVICE, NEUROVASCULAR EMBOLIZATION24 reports
- TARGET XL M0036123090Device, Vascular, for Promoting Embolization20 reports
- TARGET XL M0036129300Device, Vascular, for Promoting Embolization18 reports
- TARGET XL M0036127200Device, Vascular, for Promoting Embolization18 reports
- TARGET XL M0036121240DEVICE, NEUROVASCULAR EMBOLIZATION17 reports
- TARGET XL M0036101240Device, Vascular, for Promoting Embolization14 reports
- TARGET XL M0036101450DEVICE, NEUROVASCULAR EMBOLIZATION13 reports
- TARGET XL M0036122060Device, Vascular, for Promoting Embolization11 reports
- TARGET XL M0036123060Device, Vascular, for Promoting Embolization11 reports
- TARGET XL M0036124080DEVICE, NEUROVASCULAR EMBOLIZATION11 reports
- TARGET XL M0036101040DEVICE, NEUROVASCULAR EMBOLIZATION10 reports
- TARGET XL M0036125100Device, Vascular, for Promoting Embolization10 reports
- TARGET XL M0036121450DEVICE, NEUROVASCULAR EMBOLIZATION9 reports
- TARGET XL M0036101650Device, Vascular, for Promoting Embolization7 reports
- TARGET XL M0036102050DEVICE, NEUROVASCULAR EMBOLIZATION7 reports
- TARGET XL M0036121650DEVICE, NEUROVASCULAR EMBOLIZATION6 reports
- TARGET XL M0036122030DEVICE, NEUROVASCULAR EMBOLIZATION6 reports
- TARGET XL M0036121850DEVICE, NEUROVASCULAR EMBOLIZATION5 reports
- TARGET XL M0036101850Device, Vascular, for Promoting Embolization5 reports
- TARGET XL M0036115150DEVICE, NEUROVASCULAR EMBOLIZATION4 reports
- TARGET XL M0036102450DEVICE, NEUROVASCULAR EMBOLIZATION4 reports
- TARGET XL M0036122050DEVICE, NEUROVASCULAR EMBOLIZATION3 reports
- TARGET XL M0036107200Device, Vascular, for Promoting Embolization3 reports
- TARGET XL M0036116200Device, Vascular, for Promoting Embolization2 reports
- TARGET XL M0036118300DEVICE, NEUROVASCULAR EMBOLIZATION2 reports
- TARGET XL M0036106200DEVICE, NEUROVASCULAR EMBOLIZATION2 reports
- TARGET XL M0036119300Device, Vascular, for Promoting Embolization1 report
- TARGET XL M0036102250Device, Vascular, for Promoting Embolization1 report
- TARGET XL M0036108300Device, Vascular, for Promoting Embolization1 report
- TARGET XL M0036109300DEVICE, NEUROVASCULAR EMBOLIZATION1 report
Recent TARGET XL adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionSep 23, 2026Premature Separation
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50873847 ↗MalfunctionAug 6, 2026Premature Separation
It was reported that the subject coil got stuck and detached inside the microcatheter. The subject device was removed, and the procedure was completed successfully. No clinical consequences were reported to the patient due to this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50167285 ↗InjuryJul 6, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ANEURYSM RECANALIZATION WAS OBSERVED POST PROCEDURE AND WAS TREATED WITH CLIPPING. THE OUTCOME OF THIS ADVERSE EVENT IS ON GOING. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: Aneurysm
MAUDE report 25727448 ↗MalfunctionJun 15, 2026Fracture
IT WAS REPORTED THAT THE SUBJECT MAIN COIL FAILED TO DETACH. THE SUBJECT DEVICE WAS REPLACED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT. THE SUBJECT DEVICE WAS RETURNED FOR ANALYSIS AND THE DEVICE INVESTIGATION REVEALED THAT THE SUBJECT MAIN COIL WAS BROKEN/FRACTURED DURING USE. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25509190 ↗MalfunctionJun 4, 2026Fracture
THE SUBJECT COIL WAS RETURNED FOR ANALYSIS AND THE DEVICE INVESTIGATION REVEALED THAT THE SUBJECT COIL WAS BROKEN/FRACTURED DURING USE. THERE WERE NO CLINICAL CONSEQUENCES TO THE PATIENT REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25398353 ↗InjuryMay 28, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DETACHMENT OF THE SUBJECT COIL WAS ATTEMPTED MORE THAN 10 TIMES USING THE POWER SUPPLY, BUT WAS UNSUCCESSFUL. BECAUSE DETACHMENT COULD NOT BE ACHIEVED, THE SUBJECT COIL RETRIEVAL WAS ATTEMPTED, DURING WHICH AN ANEURYSM RUPTURE OCCURRED. THE SUBJECT COIL STRETCHED DURING RETRIEVAL AND WAS SUBSEQUENTLY REMOVED USING A SNARE. THE SUBJECT DEVICE WAS REPLACED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT. THE PATIENT IS STABLE.
Patient problems: Ruptured Aneurysm
MAUDE report 25323308 ↗MalfunctionMay 6, 2026Fracture
THE COIL (SUBJECT DEVICE) WAS RETURNED FOR ANALYSIS, AND IT WAS DISCOVERED THAT THE MAIN COIL (SUBJECT DEVICE) WAS SEEN TO BE FRACTURED NEAR THE DETACHMENT ZONE. THE SUBJECT DEVICE WAS REPLACED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25096170 ↗MalfunctionApr 30, 2026Premature Separation
IT WAS REPORTED DURING THE EMBOLIZATION OF A UNRUPTURED ANEURYSM OF THE RIGHT ANTERIOR CEREBRAL ARTERY THE SUBJECT COIL DEPLOYED INSIDE THE CATHETER WHILE ADVANCING TO THE TREATMENT SITE. IT WAS REMOVED AND REPLACED. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH NO CLINICAL CONSEQUENCES TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25038729 ↗MalfunctionMar 25, 2026Fracture; Premature Separation
THE SUBJECT COIL WAS RETURNED FOR ANALYSIS, AND IT WAS DISCOVERED THAT THE SUBJECT MAIN COIL WAS FOUND WITHIN THE MICROCATHETER DETACHED FROM THE DELIVERY WIRE AND THE SUBJECT MAIN COIL WAS SEEN TO BE FRACTURED. THE SUBJECT DEVICE WAS REPLACED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24684311 ↗InjuryMar 18, 2026Premature Separation
IT WAS REPORTED THAT DURING PROCEDURE; WHILE ADVANCING THE SUBJECT COIL THROUGH THE MICROCATHETER, THE SUBJECT COIL WAS PARTIALLY DEPLOYED IN THE ANEURYSM AND THEN THE STENT WAS PARTIALLY DEPLOYED. WHEN GOING TO ADVANCE THE REMAINING SUBJECT COIL, IT GOT PREMATURELY DETACHED FROM THE PUSHER WIRE AND THEN THE PHYSICIAN REMOVED THE SUBJECT COIL FROM PATIENT¿S BODY BY USING STENT RETRIEVER. THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24634383 ↗MalfunctionMar 9, 2026Premature Separation
IT WAS REPORTED THAT WHEN ADVANCING THE SUBJECT COIL WITHIN THE MICROCATHETER, RESISTANCE WAS ENCOUNTERED IN THE SHAFT. THE COIL WAS RETRIEVED WITH THE ENTIRE MICROCATHETER AND FOUND TO BE STRETCHED. IT WAS FOUND THAT THE SUBJECT COIL PREMATURELY DETACHED WITHIN THE MICROCATHETER. THE SUBJECT DEVICE WAS REPLACED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24545163 ↗InjuryFeb 26, 2026Premature Separation
IT WAS REPORTED THAT DURING PROCEDURE, THE SUBJECT COIL GOT DETACHED IN THE MICROCATHETER WITHOUT THE POWER SUPPLY AND THE SUBJECT COIL WAS PUSHED SUCCESSFULLY IN THE ANEURYSM USING PHYSIOLOGICAL SOLUTION AND A SYRINGE. THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24451223 ↗MalfunctionFeb 24, 2026Fracture
THE SUBJECT COIL WAS RETURNED FOR ANALYSIS, AND IT WAS DISCOVERED THAT THE SUBJECT MAIN COIL HAD APPEARED TO BE BROKEN/FRACTURED. THE SUBJECT DEVICE WAS REPLACED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24430760 ↗MalfunctionFeb 15, 2026Premature Separation
IT WAS REPORTED THAT DURING A HAEMOSTATIC EMBOLISATION PROCEDURE, REPEATED ATTEMPTS WERE MADE TO REPOSITION THE SUBJECT COIL TIGHTLY BY REWINDING IT. HOWEVER, IT WAS CONFIRMED UNDER FLUOROSCOPY THAT THE SUBJECT COIL WOULD NOT ADVANCE WHEN PULLED AND IT SEEMED THAT THE SUBJECT COIL GOT PREMATURELY DETACHED WITHIN THE MICROCATHETER. THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24341620 ↗MalfunctionFeb 13, 2026Premature Separation
IT WAS REPORTED THAT DURING THE PROCEDURE THE SUBJECT COIL WAS INITIALLY ADVANCED INTO THE MICROCATHETER WHILE THE COIL'S SHEATH WASN'T FULLY SEATED AGAINST THE HUB. A FEW LOOPS HAD ALREADY BEEN DEPLOYED IN THE MICROCATHETER. THE SUBJECT COIL WAS CAREFULLY PULLED BACK INTO THE SHEATH. THE SUBJECT COIL WAS REINSERTED INTO THE MICROCATHETER AND ADVANCED. THE SUBJECT COIL WAS VISIBLE UNDER FLUOROSCOPY, BUT IT WAS NOT OUT OF MICROCATHETER. THE SUBJECT COIL WAS FOUND TO BE DETACHED. THE SUBJECT COIL WAS REPLACED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24338434 ↗
Other Stryker Corporation products
- RemB7 models · 3,073 reports
- Prime Series21 models · 1,548 reports · 2 recalls
- TARGET114 models · 1,077 reports
- ProCuity17 models · 368 reports · 13 recalls
- Spetzler-Malis20 models · 7 reports · 19 recalls
- SYNCHRO 28 models · 313 reports · 9 recalls
- Neptune E-SEP19 models · 412 reports · 7 recalls
- StrykeFlow4 models · 552 reports · 4 recalls
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.