ENDURANTRecalls & reported problems across all models
Medtronic, Inc. · 46 models in the FDA device registry
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 169
- Deaths reported
- 11
- Injuries reported
- 136
- Recalls
- 0
We found 46 models of ENDURANT by Medtronic, Inc. in the FDA's device registry (GUDID). Together they are named in 169 adverse event reports in the FDA's MAUDE database, received between Jan 30, 2017 and May 1, 2026 — classified as 11 deaths, 136 injuries, 22 malfunctions.
The most frequently reported specific device problem is “Leak/Splash” (135 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported ENDURANT problems
Device problems
- Leak/Splash135
- Adverse Event Without Identified Device or Use Problem25
- Migration or Expulsion of Device22
- Occlusion Within Device6
- Detachment of Device or Device Component5
- Failure To Adhere Or Bond4
- Fracture4
- Material Deformation2
Patient problems
- Injury62
- Rupture25
- Insufficient Information24
- Pain19
- No Clinical Signs, Symptoms or Conditions16
- Abdominal Pain10
- No Consequences Or Impact To Patient10
- Aneurysm9
ENDURANT models
46 models, most reported first. Each model has its own page with its reports, recalls and device details.
- ENDURANT® ENBF3216C166ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT15 reports
- ENDURANT® ENBF2816C166ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT13 reports
- ENDURANT® ENBF3616C166ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death11 reports
- ENDURANT® ENBF3216C145ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT11 reports
- ENDURANT® ENBF3616C145ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death7 reports
- ENDURANT® ENBF2816C145ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death7 reports
- ENDURANT® ENLW1620C93ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT6 reports
- ENDURANT® ENBF2516C145ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death6 reports
- ENDURANT® ENLW1624C124ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT5 reports
- ENDURANT® ENLW1624C93ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT5 reports
- ENDURANT® ENLW1620C124ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT5 reports
- ENDURANT® ENLW1613C124ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT5 reports
- ENDURANT® ENBF2516C166ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT5 reports
- ENDURANT® ENBF2513C166ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death5 reports
- ENDURANT® ENBF2313C166ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT5 reports
- ENDURANT® ENBF3620C166ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT5 reports
- ENDURANT® ENLW1616C124ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT4 reports
- ENDURANT® ENEW2020C82ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT4 reports
- ENDURANT® ENCF3232C49ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death3 reports
- ENDURANT® ENBF2316C145ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT3 reports
- ENDURANT® ENBF2820C145ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT3 reports
- ENDURANT® ENLW1616C93ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- ENDURANT® ENLW1616C82ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- ENDURANT® ENLW1613C93ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death2 reports
- ENDURANT® ENEW2424C82ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- ENDURANT® ENLW1628C124ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- ENDURANT® ENBF2813C166ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death2 reports
- ENDURANT® ENBF2813C145ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death2 reports
- ENDURANT® ENBF3620C145ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- ENDURANT® ENBF3220C166ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- ENDURANT® ENBF3216C124ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- ENDURANT® ENBF2820C166ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- ENDURANT® ENLW1628C93ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- ENDURANT® ENLW1628C82ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- ENDURANT® ENLW1620C82ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- ENDURANT® ENLW1613C82ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- ENDURANT® ENLW1610C124ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death1 report
- ENDURANT® ENLW1610C93ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- ENDURANT® ENTF3636C70ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death1 report
- ENDURANT® ENCF2525C49ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- ENDURANT® ENEW2828C82ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- ENDURANT® ENEW1313C82ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- ENDURANT® ENEW1010C82ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- ENDURANT® ENBF2516C124ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- ENDURANT® ENBF2513C145ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- ENDURANT® ENBF3220C145ESYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
Recent ENDURANT adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
InjuryMay 1, 2026Leak/Splash
AN ENDURANT STENT GRAFT SYSTEM WAS IMPLANTED DURING AN UNKNOWN ENDOVASCULAR PROCEDURE. IT WAS REPORTED THAT A PATIENT REPRESENTATIVE CONTACTED TECHNICAL SERVICES APPROXIMATELY 14 YEARS LATER AND STATED THAT THE PATIENT EXPERIENCED AN ENDOLEAK THAT WAS REPAIRED 4 MONTHS PREVIOUSLY WITH AN ENDURANT CUFF. SUBSEQUENT INFORMATION RECEIVED CONFIRMED THAT THE ENDOLEAK WAS A TYPE IA INVOLVING THE ENDURANT BIFURCATED GRAFT. THE ENDOLEAK DID NOT RESOLVE FOLLOWING CUFF IMPLANTATION; THEREFORE, SIX ENDOANCHORS WERE PLACED, RESULTING IN A REDUCTION OF THE ENDOLEAK. THE PHYSICIAN LATER CONFIRMED THAT THE ENDOLEAK WAS FULLY RESOLVED ON FOLLOW-UP IMAGING. LACK OF WALL APPOSITION WAS NOTED IN THE LEFT LIMB; HOWEVER, NO TYPE IB ENDOLEAK WAS IDENTIFIED. ACCORDING TO THE PHYSICIAN, THE CAUSE OF THE TYPE IA ENDOLEAK WAS PROGRESSIVE DILATION OF THE AORTA SINCE THE INDEX PROCEDURE. NO ADDITIONAL CLINICAL SEQUELAE WERE REPORTED, AND THE PATIENT IS DOING WELL.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 25054506 ↗MalfunctionMar 30, 2026Fracture; Leak/Splash; Migration or Expulsion of Device; Detachment of Device or Device Component
AN ENBF3216C166E STENT GRAFT WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF AN AAA. IT WAS NOTED THAT THE PATIENT IS NOW BEING FOLLOWED UP BY A PHYSICIAN WHO WAS NOT THE INITIAL IMPLANTER. IT WAS REPORTED APPROXIMATELY 15 YEARS POST THE INDEX PROCEDURE, FOLLOW-UP CT SHOWED A IA ENDOLEAK WITH ANEURYSM SAC EXPANSION. REVIEW OF THE CT AGAIN 2 DAYS LATER DETERMINED THAT THE SUPRARENAL STENT HAD BECOME DETACHED FROM THE MAIN BODY AND THE MAIN BODY HAD MIGRATED AWAY FROM THE RENAL ARTERIES WITH A IA ENDOLEAK PRESENT. THE PHYSICIAN PLANS TO DISCUSS FURTHER TREATMENT OPTIONS. PER THE PHYSICIAN THE CAUSE OF THE DETACHED STENT AND TYPE IA ENDOLEAK IS UNDETERMINED. NO ADDITIONAL CLINICAL SEQUALAE WAS PROVIDED AND THE PATIENT WILL BE MONITORED.
Patient problems: Aneurysm expansion
MAUDE report 24711190 ↗InjuryDec 22, 2025Leak/Splash; Leak/Splash
AN ENDURANT STENT GRAFT SYSTEM WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF A 60MM AAA. THE DIAMETER OF THE AORTA AT THE RENAL ARTERY WAS 28MM. IT WAS REPORTED THAT THE PATIENT PRESENTED TO THE HOSPITAL APPROXIMATELY 14 YEARS AND 9 MONTHS LATER WITH PAIN AND ENDOLEAKS WERE IDENTIFIED. A TYPE IA ENDOLEAK WAS ASSOCIATED WITH THE ENBF2513C145E AND A TYPE IB WAS ASSOCIATED WITH THE ENLW1613C124E LIMB. INTERVENTION WAS PERFORMED ON THE SAME DATE AND AN ENDURANT CUFF AND ENDURANT II LIMB STENT GRAFT WERE IMPLANTED TO REPAIR THE ENDOLEAKS. PER THE PHYSICIAN, THE CAUSE OF THE EVENT WAS ATTRIBUTED TO DISEASE PROGRESSION OVER A 14 YEAR PERIOD. NO ADDITIONAL CLINICAL SEQUALAE WAS PROVIDED AND THE PATIENT IS FINE.
Patient problems: Pain
MAUDE report 23861839 ↗InjuryDec 22, 2025Leak/Splash; Leak/Splash
AN ENDURANT STENT GRAFT SYSTEM WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF A 60MM AAA ON . THE DIAMETER OF THE AORTA AT THE RENAL ARTERY WAS 28MM.IT WAS REPORTED THAT THE PATIENT PRESENTED TO THE HOSPITAL APPROXIMATELY 14 YEARS AND 9 MONTHS LATER WITH PAIN AND ENDOLEAKS WERE IDENTIFIED. A TYPE IA ENDOLEAK WAS ASSOCIATED WITH THE ENBF2513C145E AND A TYPE IB WAS ASSOCIATED WITH THE ENLW1613C124E LIMB. INTERVENTION WAS PERFORMED ON THE SAME DATE AND AN ENDURANT CUFF AND ENDURANT II LIMB STENT GRAFT WERE IMPLANTED TO REPAIR THE ENDOLEAKS. PER THE PHYSICIAN, THE CAUSE OF THE EVENT WAS ATTRIBUTED TO DISEASE PROGRESSION OVER A 14 YEAR PERIOD. NO ADDITIONAL CLINICAL SEQUALAE WAS PROVIDED AND THE PATIENT IS FINE.
Patient problems: Pain
MAUDE report 23861835 ↗InjuryJan 3, 2025Leak/Splash; Leak/Splash
IT WAS REPORTED THAT A TYPE IB OCCURRED IN AN ENDURANT II LIMB WHICH WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF A 60MM ANEURYSM. ANOTHER ENDURANT LIMB WAS PLACED DURING THE PROCEDURE AS INTERVENTION. THE CAUSE OF THE EVENT WAS ATTRIBUTED TO DISEASE PROGRESSION AND VESSEL TORTUOSITY. THE EVENT WAS DISCOVERED WHEN THE PATIENT PRESENTED EMERGENTLY. THE ISSUE WAS RESOLVED, AND THE DEVICE REMAINS IMPLANTED AND IN SERVICE.
Patient problems: Insufficient Information
MAUDE report 21065749 ↗InjuryDec 10, 2024Leak/Splash; Leak/Splash
IT WAS REPORTED THAT A PATIENT WAS TREATED FOR AN ANEURYSM USING A ENDURANT STENT GRAFT SYSTEM. APPROX. 13 YEARS, 4 MONTHS POST INDEX PROCEDURE A COMPUTED TOMOGRAPHY CONDUCTED WITHOUT CONTRAST DUE TO THE PATIENT'S POOR KIDNEY FUNCTION, REVEALED A TYPE IB ENDOLEAK. THE PHYSICIAN'S FINDINGS WERE BASED ON WHAT APPEARED TO BE NON-OPPOSED LIMBS OBSERVED IN THE IMAGING. THE HEALTHCARE PROFESSIONAL IDENTIFIED ANATOMY AND DISEASE PROGRESSION AS THE CAUSE OF THE EVENT. IT WAS CONFIRMED THAT THERE WERE NO ALLEGATIONS OR ISSUES RELATED TO THE TWO ENDURANT CUFFS IMPLANTED DURING THE INITIAL PROCEDURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20890670 ↗InjuryNov 6, 2024Leak/Splash; Leak/Splash
AN ENDURANT STENT GRAFT SYSTEM WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF AN ABDOMINAL AORTIC ANEURYSM. IT WAS REPORTED A FOLLOW UP CT SCAN CONDUCTED APPTOX. 13 YEARS, 6 MONTHS POST INDEX PROCEDURE, REVEALED A SUSPECTED ENDOLEAK BUT IT WAS NOT CONFIRMED. THE PHYSICIAN SCHEDULED AN EXPLORATORY ANGIOGRAM 18 DAYS LATER WHICH IDENTIFIED A SUSPECTED TYPE IB ENDOLEAK ON THE LEFT ILIAC ENDURANT LIMB. INTERVENTION WAS PERFORMED ON THE SAME DAY AND A ENDURANT (ETLW1620C93E) LIMB EXTENSION WAS IMPLANTED TO ADDRESS THE ENDOLEAK FIX THE LEAK, EFFECTIVELY RESOLVING IT. PER THE PHYSICIAN THE CAUSE OF THE TYPE IB ENDOLEAK WAS ANATOMY RELATED DUE THE LEFT ILIAC ENLARGING OVER TIME EXCEEDING THE ORIGINAL STENT DIAMETER SINCE THE INITIAL IMPLANTATION. NO ADDITIONAL CLINICAL SEQUALAE WERE PROVIDED AND THE PATIENT IS FINE.
Patient problems: Insufficient Information
MAUDE report 20619647 ↗InjuryMay 3, 2024Leak/Splash; Leak/Splash
AN ENDURANT STENT GRAFT SYSTEM AND AN ANEURX LIMB WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF AN ABDOMINAL AORTIC ANEURYSM. IT WAS REPORTED APPROXIMATELY 14 YEARS POST THE INDEX PROCEDURE, THAT THE PATIENT PRESENTED EMERGENTLY EXPERIENCING ABDOMINAL PAIN. A CT SCAN REVEALED A TYPE IA ENDOLEAK WITH A 96MM ABDOMINAL AORTIC ANEURYSM. INTERVENTION WAS PERFORMED, AND AN ENDURANT II/IIS CUFF (ETCF3636C49E) WAS PLACED IN THE RIGHT RENAL ARTERY. THE LEFT RENAL ARTERY WAS COVERED, AND THE RIGHT RENAL WAS STENTED. A FINAL ANGIOGRAM WAS CONDUCTED, AND THE TYPE IA ENDOLEAK WAS RESOLVED. PER THE PHYSICIAN THE CAUSE OF THE TYPE IA ENDOLEAK WAS ANATOMY RELATED DUE TO THE PATIENTS AORTIC NECK DILATATION COMPROMISING THE SEAL OF THE STENT GRAFT. NO ADDITIONAL CLINICAL SEQUALAE WERE PROVIDED AND THE PATIENT IS FINE.
Patient problems: Abdominal Pain
MAUDE report 19243522 ↗MalfunctionFeb 9, 2024Leak/Splash; Leak/Splash
AN ENDURANT STENT GRAFT SYSTEM AND ANEURX ILIAC LIMB WERE IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF AN AAA. IT WAS REPORTED APPROXIMATELY 13 YEARS POST THE INDEX PROCEDURE, THE PATIENT RANG TECHNICAL SERVICES AND SAID THAT ONE OF THE STENT GRAFTS WAS LEAKING. THE PATIENT IS UNSURE WHICH GRAFT BUT KNOWS THAT IT WAS IMPLANTED IN 2011. THE PATIENT STATED THAT THE ANEURYSM HAS GROWN FROM 50MM TO 80MM ON A RECENT CT. THE PATIENT DID NOT REPORT ANY SYMPTOMS. NO CAUSE WAS PROVIDED. NO ADDITIONAL CLINICAL SEQUALAE WERE PROVIDED AND THE PATIENT WILL BE MONITORED.
Patient problems: Aneurysm; No Clinical Signs, Symptoms or Conditions
MAUDE report 18675634 ↗InjuryFeb 6, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AN ENDURANT STENT GRAFT SYSTEM WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF A 106MM AAA. IT WAS REPORTED THAT A CT WAS TAKEN APPROXIMATELY 13 YEARS POST THE INDEX PROCEDURE SHOWED A TYPE IA ENDOLEAK. IT WAS NOTED THAT THE PATIENT HAD A NON-MDT CUFF AND LIMBS PRESENT WITHIN THE ENDURANT GRAFT WHICH WERE IMPLANTED ON AN UNKNOWN DATE. THE ENDURANT STENT GRAFTS AND NON-MDT STENT GRAFTS WERE EXPLANTED. THE PATIENTS CONDITION IS POST THE EXPLANT PROCEDURE WAS NOTED AS ALIVE AND WELL. PER THE PHYSICIAN THE CAUSE OF THE ENDOLEAK WAS ANATOMY RELATED AND DUE TO AORTIC NECK DEGENERATION. NO ADDITIONAL SEQUELAE WERE REPORTED AND THE PATIENTS IS FINE.
Patient problems: Insufficient Information
MAUDE report 18650670 ↗InjuryFeb 6, 2024Leak/Splash; Leak/Splash
AN ENDURANT STENT GRAFT SYSTEM WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF A 106MM AAA. IT WAS REPORTED THAT A CT WAS TAKEN APPROXIMATELY 13 YEARS POST THE INDEX PROCEDURE SHOWED A TYPE IA ENDOLEAK. IT WAS NOTED THAT THE PATIENT HAD A NON-MDT CUFF AND LIMBS PRESENT WITHIN THE ENDURANT GRAFT WHICH WERE IMPLANTED ON AN UNKNOWN DATE. THE ENDURANT STENT GRAFTS AND NON-MDT STENT GRAFTS WERE EXPLANTED. THE PATIENTS CONDITION IS POST THE EXPLANT PROCEDURE WAS NOTED AS ALIVE AND WELL. PER THE PHYSICIAN THE CAUSE OF THE ENDOLEAK WAS ANATOMY RELATED AND DUE TO AORTIC NECK DEGENERATION. NO ADDITIONAL SEQUELAE WERE REPORTED AND THE PATIENTS IS FINE.
Patient problems: Insufficient Information
MAUDE report 18650650 ↗InjuryJan 12, 2024Leak/Splash; Leak/Splash
AN ENDURANT BIFURCATE STENT GRAFT SYSTEM WAS IMPLANTED IN THE ENDOVASCULAR TREATMENT OF A UNKNOWN SIZED AAA. IT WAS REPORTED THE PATIENT PRESENTED TO ER, A CT WAS PERFORMED WHICH SHOWED BLOOD IN THE ABDOMEN DIAGNOSED AS A ANEURYSM RUPTURE AND ALSO AN ENDOLEAK. THE ENDOLEAK WAS THOUGHT TO BE TYPE II OR TYPE III ENDOLEAK. THE PATIENT WAS TRANSFERRED TO A SURGICAL HYBRID THEATRE TO PERFORMED A ANGIOGRAM. AFTER SEVERAL IMAGES AND VIEWPOINTS WERE COMPLETED, IT WAS THOUGHT THAT A POSSIBLE AREA OF CONTRAST WAS SEEN OUTSIDE THE STENT AND WITHIN THE ABDOMINAL SAC. THE AREA OF THE GRAFT WAS THE IPSILATERAL SIDE (RCIA) OF THE MAIN BODY BIFURCATE. THIS AREA WAS THEN RELINED WITH A 16X16X82 STENT GRAFT. FOLLOW-UP IMAGING WAS PERFORMED AND CONTRAST WAS NO LONGER FEEDING INTO THE SAC. OTHER IMAGING COULD NOT FIND ANY OTHER LEAKS. PER THE PHYSICIAN THE CAUSE OF THE SUSPECTED TYPE III ENDOLEAK COULD NOT BE DETERMINED. NO ADDITIONAL CLINICAL "SEQUELAE" WERE PROVIDED AND THE PATIENT IS FINE.
Patient problems: Rupture
MAUDE report 18501114 ↗MalfunctionDec 6, 2023Leak/Splash; Leak/Splash
AN ENDURANT STENT GRAFT SYSTEM WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF A 55 X 57MM ABDOMINAL AORTIC ANEURYSM. IT WAS REPORTED APPROXIMATELY 12 YEARS POST THE PROCEDURE, FOLLOW UP CT SCAN REVEALED A POSSIBLE TYPE III ENDOLEAK LOCATED IN THE DISTAL AORTA, HOWEVER IT IS UNCLEAR WHICH ILIAC LIMB CONTAINED THE AFFECTED. IT WAS NOTED THE PATIENT IS ASYMPTOMATIC. PER THE PHYSICIAN THE CAUSE OF THE SUSPECTED TYPE III ENDOLEAK IS DUE TO A HOLE WORN IN THE GRAFT. NO ADDITIONAL CLINICAL SEQUALAE WERE PROVIDED AND THE PATIENT WILL BE MONITORED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18272701 ↗InjuryApr 11, 2023Leak/Splash; Leak/Splash
AN ENDURANT II BIFURCATE, ENDURANT AORTIC EXTENSION AND LIMBS WERE IMPLANTED IN THE ENDOVASCULAR TREATMENT OF A 65MM AAA. IT WAS REPORTED THAT WHEN THE PATIENT RETURNED FOR FOLLOW-UP AT 10 YEARS POST-IMPLANT WHERE A TYPE III ENDOLEAK WAS NOTED IN THE LEFT ILIAC ARTERY AT THE OVERLAP OF AN ENDURANT LIMB ETLW1624C93E AND THE ENEW2828C82E CUFF. INTERVENTION WAS CARRIED OUT 3 DAYS LATER WHERE AN ILIAC EXTENSION LIMB ( SNV31076806) WAS PLACED TO CORRECT THE TYPE IIIA ENDOLEAK. PER THE PHYSICIAN THE CAUSE OF THE EVENT IS ANATOMY AND ALSO OFF LABEL USE OF THE ENDURANT CUFF IN THE ILIAC ARTERY. NO ADDITIONAL CLINICAL SEQUELAE WERE PROVIDED AND THE PATIENT IS FINE.
Patient problems: Insufficient Information
MAUDE report 16711464 ↗MalfunctionFeb 22, 2023Leak/Splash; Leak/Splash
AN ENDURANT BIFURCATE STENT GRAFT SYSTEM WAS IMPLANTED IN THE ENDOVASCULAR TREATMENT OF A AAA . A CTA WAS PERFORMED , WHICH IDENTIFIED A PROXIMAL TYPE IA ENDOLEAK AND BILATERAL TYPE IB ENDOLEAKS. PER THE PHYSICIAN THE CAUSE OF THE ENDOLEAKS IS DISEASE PROGRESSION. NO ADDITIONAL CLINICAL SEQUALAE WERE PROVIDED AND THE PATIENT WILL BE MONITORED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16416417 ↗
Other Medtronic, Inc. products
- CapSureFix Novus MRI SureScan29 models · 87,337 reports
- Medtronic Sprint Quattro Lead67 models · 45,880 reports · 1 recall
- Intellis AdaptiveStim3 models · 35,469 reports
- SYNCHROMED II11 models · 32,260 reports · 4 recalls
- CAPSUREFIX NOVUS17 models · 27,547 reports
- INTERSTIM30 models · 24,415 reports · 1 recall
- Sprint Quattro Secure S MRI SureScan7 models · 23,549 reports
- Medtronic LINQ Heart Monitor11 models · 19,366 reports · 3 recalls
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page