Medical device recalls: September 2023
The FDA posted 155 medical device recall records in September 2023, from 72 recall events by 63 companies. 16 are Class I, the most serious category.
Each product in a recall gets its own record, so one recall event can cover several records. What recall classes mean.
Companies with the most recall events
- MEDLINE INDUSTRIES, LP - Northfield · 3 events, 3 records, 1 Class I
- Abbott Medical · 2 events, 9 records, 7 Class I
- Stryker Corporation · 2 events, 8 records
- Philips Medical Systems Nederland B.V. · 2 events, 4 records
- B. Braun Medical, Inc. · 2 events, 3 records
- Philips North America Llc · 2 events, 3 records
- Baxter Healthcare Corporation · 2 events, 2 records
- Keystone Industries · 2 events, 2 records
FDA root cause
- Under Investigation by firm · 80
- Process control · 16
- Nonconforming Material/Component · 16
- Device Design · 10
- Other · 8
- Software design · 6
- Radiation Control for Health and Safety Act · 4
- Component design/selection · 4
Class I recalls (16)
The most serious: a reasonable probability that using the device will cause serious health problems or death.
- Z-2631-2023 · Philips Respironics, Inc. · posted Sep 28, 2023 · Open, Classified
Power Management PCBAs may malfunction, causing a power failure leading to ventilator loss of function.
- Z-2525-2023 · Hamilton Medical, Inc. · posted Sep 20, 2023 · Open, Classified
Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or the capacitor to lose function and lead to interruption of ventilation.
- Z-2526-2023 · Hamilton Medical, Inc. · posted Sep 20, 2023 · Open, Classified
Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or the capacitor to lose function and lead to interruption of ventilation.
- Z-2527-2023 · Hamilton Medical, Inc. · posted Sep 20, 2023 · Open, Classified
Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or the capacitor to lose function and lead to interruption of ventilation.
- Z-2528-2023 · Hamilton Medical, Inc. · posted Sep 20, 2023 · Open, Classified
Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or the capacitor to lose function and lead to interruption of ventilation.
- Z-2529-2023 · Hamilton Medical, Inc. · posted Sep 20, 2023 · Open, Classified
Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or the capacitor to lose function and lead to interruption of ventilation.
- Z-2530-2023 · Hamilton Medical, Inc. · posted Sep 20, 2023 · Open, Classified
Degrading capacitors on the control board of ventilators and spare parts may leak electrolyte onto the control board causing a short circuit on the board and/or the capacitor to lose function and lead to interruption of ventilation.
- HUDSON RCI Addipak, UNIT DOSE VIALS, 5mL Sterile 0.9% NaCl Solution for Inhalation USP. REF RHUD59UClass IZ-2514-2023 · MEDLINE INDUSTRIES, LP - Northfield · posted Sep 14, 2023 · Open, Classified
Product dispositioned for scrap for sterility failure investigation that was inadvertently shipped to customers.
- Z-2505-2023 · Abbott Medical · posted Sep 11, 2023 · Open, Classified
Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2506-2023 · Abbott Medical · posted Sep 11, 2023 · Open, Classified
Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2507-2023 · Abbott Medical · posted Sep 11, 2023 · Open, Classified
Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2508-2023 · Abbott Medical · posted Sep 11, 2023 · Open, Classified
Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2509-2023 · Abbott Medical · posted Sep 11, 2023 · Open, Classified
Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2510-2023 · Abbott Medical · posted Sep 11, 2023 · Open, Classified
Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2511-2023 · Abbott Medical · posted Sep 11, 2023 · Open, Classified
Firm has received complaints from patients who are unable to exit MRI (Magnetic Resonance Imaging) mode on their IPGs (Implantable Pulse Generators).
- Z-2450-2023 · Mallinckrodt Manufacturing LLC · posted Sep 9, 2023 · Open, Classified
The One-Way Valve, 22F x 22M may stick and prevent or reduce the flow of ventilated air or oxygen.
Class II recalls (137)
The device may cause temporary or medically reversible health problems, or the chance of serious harm is remote.
- Z-2520-2023 · Philips Healthcare · posted Sep 30, 2023 · Open, Classified
Philips has identified three software issues with compliance concerns to Subchapter J: Issue 1: Coronary Computed Tomography Angiography (CTA) scan may not be triggered at the optimal time. Issue 2: Use of aborted surview for scan planning will result in…
- Z-2666-2023 · Siemens Healthcare Diagnostics, Inc. · posted Sep 30, 2023 · Open, Classified
There is a potential for a positive bias on Quality Control (QC) and patient sample results when using some IRON_2 reagent wedge pairs. When the issue occurs, the observed bias will vary wedge to wedge.
- Z-2648-2023 · Siemens Medical Solutions USA, Inc · posted Sep 29, 2023 · Open, Classified
In some cases, when lubricating grease is present within the headband of the over-ear headphones, it may cause visible, dot- or lineshaped, fat-isointense artifacts during head examinations only. These potential artifacts depend on the position of the…
- Z-2649-2023 · MEDLINE INDUSTRIES, LP - Northfield · posted Sep 29, 2023 · Open, Classified
The kits incorrectly contain CirClamp subassembly 345CRSAK which results in the kits containing an incorrect bell and base size.
- Z-2650-2023 · Icecure Medical Ltd · posted Sep 29, 2023 · Open, Classified
Updated User Manual DSR3200000 Rev. E to include the safety guidelines in case of any mechanical damage (e.g. bent cryoprobe)
- Z-2651-2023 · Covidien · posted Sep 29, 2023 · Open, Classified
Inadequate internal fixation of the power inlet port to the cuff pressure manager device causes the external power inlet to became dislodged within the device housing after several uses, which prevents the device from being charged, and could lead to…
- Z-2652-2023 · Ge Medical Systems, Israel Ltd. · posted Sep 29, 2023 · Open, Classified
Some Venue Go Standard Carts can develop an internal failure of the vertical/horizontal tilt adjustment mechanism which can result in the Venue Go system detaching from the cart and falling.
- Z-2653-2023 · Apellis Pharmaceuticals, Inc. · posted Sep 29, 2023 · Open, Classified
19-gauge x 1" inch filter needles showed appearances of a small fraction of non-preferred characteristics. A causal relationship has not been established between the structural variations in this 19-gauge filter needle and the rare events of retinal vasculitis
- Z-2654-2023 · Philips North America Llc · posted Sep 29, 2023 · Open, Classified
A software issue prevents the monitor from alarming when the high/low acoustic respiration rate (RRa) limits are violated.
- Z-2655-2023 · Philips North America Llc · posted Sep 29, 2023 · Open, Classified
A software issue prevents the monitor from alarming when the high/low acoustic respiration rate (RRa) limits are violated.
- Z-2656-2023 · GE Medical Systems China Co., Ltd. · posted Sep 29, 2023 · Open, Classified
There is a potential interruption of data communication between E-modules inserted in the F2-01 Frame and CARESCAPE ONE and CARESCAPE Canvas 1000 patient monitors if the F2-01 Frame has not been powered down within the last 120 days.
- Z-2657-2023 · Medtronic Neuromodulation · posted Sep 29, 2023 · Terminated
The original version of the A71100 Restore Clinician Programmer Application has been identified to have a compatibility issue with some legacy clinician programmer software resulting in the programmer having an inability to establish communication with the…
- Z-2658-2023 · Thoratec Corp. · posted Sep 29, 2023 · Open, Classified
Inability to start and/or complete the coring procedure due to inadequate sharpness of the Apical Coring Knife, provided with Left Ventricular Assist System, could result in an extended procedure or surgical time while the backup coring knife is acquired.
- Z-2659-2023 · Olympus Corporation of the Americas · posted Sep 29, 2023 · Open, Classified
Non-conformances in Veran devices (ig4 Image Guided System, SPiN Thoracic Navigation System, SPiN Planning Laptop Workstation, and all associated navigation instruments) manufacturing to design requirements and insufficient evidence to demonstrate…
- Veran Endobronchial:Class IIZ-2660-2023 · Olympus Corporation of the Americas · posted Sep 29, 2023 · Open, Classified
Non-conformances in Veran devices (ig4 Image Guided System, SPiN Thoracic Navigation System, SPiN Planning Laptop Workstation, and all associated navigation instruments) manufacturing to design requirements and insufficient evidence to demonstrate…
- Veran : PercutaneousClass IIZ-2661-2023 · Olympus Corporation of the Americas · posted Sep 29, 2023 · Open, Classified
Non-conformances in Veran devices (ig4 Image Guided System, SPiN Thoracic Navigation System, SPiN Planning Laptop Workstation, and all associated navigation instruments) manufacturing to design requirements and insufficient evidence to demonstrate…
- Veran : EndobronchialClass IIZ-2662-2023 · Olympus Corporation of the Americas · posted Sep 29, 2023 · Open, Classified
Non-conformances in Veran devices (ig4 Image Guided System, SPiN Thoracic Navigation System, SPiN Planning Laptop Workstation, and all associated navigation instruments) manufacturing to design requirements and insufficient evidence to demonstrate…
- Z-2663-2023 · Olympus Corporation of the Americas · posted Sep 29, 2023 · Open, Classified
Non-conformances in Veran devices (ig4 Image Guided System, SPiN Thoracic Navigation System, SPiN Planning Laptop Workstation, and all associated navigation instruments) manufacturing to design requirements and insufficient evidence to demonstrate…
- Z-2664-2023 · Olympus Corporation of the Americas · posted Sep 29, 2023 · Open, Classified
Non-conformances in Veran devices (ig4 Image Guided System, SPiN Thoracic Navigation System, SPiN Planning Laptop Workstation, and all associated navigation instruments) manufacturing to design requirements and insufficient evidence to demonstrate…
- Z-2665-2023 · Qiagen GmbH · posted Sep 29, 2023 · Open, Classified
Handbook Revision (Rev13) a dilution step is indicated as an Action when having the Flag SAMPLE_INT_CTRL_FAIL. A dilution of CRC tissue could lead to a false negative result. To remove ambiguity, an alteration must be made to the S the sample result with…
- Z-2636-2023 · J&T Health and Wellness LLC · posted Sep 28, 2023 · Open, Classified
In some cases the communication isolator installed in the Model 52X can cause a disturbance in the glass-filter safety circuit.
- Z-2645-2023 · Stryker Corporation · posted Sep 28, 2023 · Open, Classified
Expired Product distributed
- Z-2646-2023 · CareFusion 303, Inc. · posted Sep 28, 2023 · Open, Classified
After dispensing a timed dose medication for a patient, the automated dispensing cabinet software may continue to show the already dispensed medication dose is still available for dispense, which could lead to duplicate medication administration.
- Z-2647-2023 · Baxter Healthcare Corporation · posted Sep 28, 2023 · Open, Classified
Epiphany, now a Baxter Healthcare company, is issuing an Urgent Medical Device Correction for the Cardio Server E3 ECG Management System software listed below due to a report of the caliper tool becoming non-responsive, preventing the caliper function from…
- Z-2642-2023 · Wolf, Henke Sass, Gmbh · posted Sep 27, 2023 · Open, Classified
Sterile barrier might be damaged compromising the sterility of the device.
- Z-2643-2023 · B. Braun Medical, Inc. · posted Sep 27, 2023 · Open, Classified
The sterile blister packaging may be damaged, and sterility may be compromised
- Z-2644-2023 · B. Braun Medical, Inc. · posted Sep 27, 2023 · Open, Classified
The sterile blister packaging may be damaged, and sterility may be compromised
- Z-2637-2023 · 3M Company - Health Care Business · posted Sep 26, 2023 · Open, Classified
Specific lots of 3M Attest Super Rapid Readout Biological Indicators (1492V), 3M Attest Super Rapid 5 Steam-Plus Challenge (41482V, 41482VF), and 3M Attest Super Rapid Readout Steam Challenge (1496V) may contain biological indicators with a cap that melts,…
- Z-2638-2023 · 3M Company - Health Care Business · posted Sep 26, 2023 · Open, Classified
Specific lots of 3M Attest Super Rapid Readout Biological Indicators (1492V), 3M Attest Super Rapid 5 Steam-Plus Challenge (41482V, 41482VF), and 3M Attest Super Rapid Readout Steam Challenge (1496V) may contain biological indicators with a cap that melts,…
- Z-2639-2023 · 3M Company - Health Care Business · posted Sep 26, 2023 · Open, Classified
Specific lots of 3M Attest Super Rapid Readout Biological Indicators (1492V), 3M Attest Super Rapid 5 Steam-Plus Challenge (41482V, 41482VF), and 3M Attest Super Rapid Readout Steam Challenge (1496V) may contain biological indicators with a cap that melts,…
- Z-2640-2023 · 3M Company - Health Care Business · posted Sep 26, 2023 · Open, Classified
Specific lots of 3M Attest Super Rapid Readout Biological Indicators (1492V), 3M Attest Super Rapid 5 Steam-Plus Challenge (41482V, 41482VF), and 3M Attest Super Rapid Readout Steam Challenge (1496V) may contain biological indicators with a cap that melts,…
- Z-2641-2023 · Waldemar Link GmbH & Co. KG (Mfg Site) · posted Sep 26, 2023 · Open, Classified
Product is labeled with incorrect offset.
- Z-2632-2023 · Covidien LP · posted Sep 25, 2023 · Open, Classified
Some catheter kits labeled as 23 cm implant length incorrectly included catheters of 28 cm implant length; the actual catheter implant length is identifiable based upon the correct labeling on the catheter body.
- Z-2633-2023 · Exocad GmbH · posted Sep 25, 2023 · Open, Classified
A software library filtering error has been discovered which occurs when users are using the Step-by-Step Full Drill Protocol export functionality of exoplan 3.1 Rijeka. When a guided surgery treatment approach is selected, along with a Step-by-Step Full…
- Z-2634-2023 · Inmar Supply Chain Solutions, LLC · posted Sep 25, 2023 · Open, Classified
Various medical devices potentially exposed to rodent and rodent activity. In addition, medical devices may have been subjected to temperatures in excess of storage requirements on product labeling.
- Z-2635-2023 · Fresenius Kabi USA, LLC · posted Sep 25, 2023 · Open, Classified
Start-up time for the flow rate range greater than 50 ml/hr, and less than 200 ml/hr may exceed the specified 6 minutes, depending on the characteristics of air bubble entrapment within the Intermediate Pumping Chamber (IPC) of the administration set
- Z-2628-2023 · Ambu Inc. · posted Sep 22, 2023 · Open, Classified
Multiple impacts, for example from being dropped, can cause to the Ambu aView 2 Advance to short-circuit and under special circumstances make the lithium-ion battery in the device combust leading to smoke and flames
- Z-2622-2023 · Avanos Medical, Inc. · posted Sep 21, 2023 · Completed
Avanos has received an increase in complaints from customers for COOLIEF RF Generators producing F100 and F101 faults.
- Z-2623-2023 · Ortho-Clinical Diagnostics, INc. · posted Sep 21, 2023 · Open, Classified
Samples containing high levels of ALKP (or an interfering substance) could deplete the available substrate in the reagent layer of a VITROS ALKP Slide and not post the substrate deleption (DP) code, which may result in the System reporting an incorrect…
- Z-2624-2023 · Ortho-Clinical Diagnostics, INc. · posted Sep 21, 2023 · Open, Classified
Samples containing high levels of ALKP (or an interfering substance) could deplete the available substrate in the reagent layer of a VITROS ALKP Slide and not post the substrate deleption (DP) code, which may result in the System reporting an incorrect…
- Z-2625-2023 · Remote Diagnostic Technologies Ltd. · posted Sep 21, 2023 · Open, Classified
Full screen error message may occur on patient monitors with affected hardware version, either during or after laryngoscopes are unplugged from monitors, informing users a 60-100 second shutdown/restart are required. Error prevents: viewing graphical…
- Z-2626-2023 · O&M Halyard, Inc. · posted Sep 21, 2023 · Open, Classified
One respirator sample failed a filtration efficiency test. This respirator may not provide adequate protection to the user.
- Z-2627-2023 · B. Braun Medical, Inc. · posted Sep 21, 2023 · Open, Classified
Product may be mislabeled with an incorrect lid stock label.
- Z-2618-2023 · Insulet Corporation · posted Sep 20, 2023 · Open, Classified
An error message was received when using the Omnipod 5 App on compatible smartphones that prevented phone control users from controlling the Omnipod 5 Automated Insulin Delivery System from their Omnipod 5 App which may cause a delay in therapy. To reduce…
- MINISCAV (tm) Vacuum Pump ↗Class IIZ-2619-2023 · R A Medical Services · posted Sep 20, 2023 · Open, Classified
Inadequate documentation of acceptance activity
- Z-2621-2023 · Smith & Nephew Inc · posted Sep 20, 2023 · Open, Classified
The firm conducting a recall due to a complaint received indicating that a package contained a LEGION NARROW PS OXIN SZ 4N LT implant instead of a LEGION NARROW PSvOXIN SZ 5N LT as described on the product label.
- Z-2596-2023 · Stryker Corporation · posted Sep 19, 2023 · Open, Classified
Potential for the Break-Away Femoral Nozzle the applicator tip connecting the cement cartridge, to disassemble or break off during use, can lead to the potential for loss of function of the ACM system and bio-incompatibility due to components falling into…
- Z-2597-2023 · Stryker Corporation · posted Sep 19, 2023 · Open, Classified
Potential for the Break-Away Femoral Nozzle the applicator tip connecting the cement cartridge, to disassemble or break off during use, can lead to the potential for loss of function of the ACM system and bio-incompatibility due to components falling into…
- Z-2598-2023 · Stryker Corporation · posted Sep 19, 2023 · Open, Classified
Potential for the Break-Away Femoral Nozzle the applicator tip connecting the cement cartridge, to disassemble or break off during use, can lead to the potential for loss of function of the ACM system and bio-incompatibility due to components falling into…
- Z-2599-2023 · Stryker Corporation · posted Sep 19, 2023 · Open, Classified
Potential for the Break-Away Femoral Nozzle the applicator tip connecting the cement cartridge, to disassemble or break off during use, can lead to the potential for loss of function of the ACM system and bio-incompatibility due to components falling into…
- Z-2600-2023 · Stryker Corporation · posted Sep 19, 2023 · Open, Classified
Potential for the Break-Away Femoral Nozzle the applicator tip connecting the cement cartridge, to disassemble or break off during use, can lead to the potential for loss of function of the ACM system and bio-incompatibility due to components falling into…
- Z-2601-2023 · Stryker Corporation · posted Sep 19, 2023 · Open, Classified
Potential for the Break-Away Femoral Nozzle the applicator tip connecting the cement cartridge, to disassemble or break off during use, can lead to the potential for loss of function of the ACM system and bio-incompatibility due to components falling into…
- Z-2602-2023 · Stryker Corporation · posted Sep 19, 2023 · Open, Classified
Potential for the Break-Away Femoral Nozzle the applicator tip connecting the cement cartridge, to disassemble or break off during use, can lead to the potential for loss of function of the ACM system and bio-incompatibility due to components falling into…
- Z-2603-2023 · Encore Medical, LP · posted Sep 19, 2023 · Open, Classified
Orthopedic device components were not subjected to final sterilization before shipment, which if implanted may lead to varying degrees of infection, which may require treatment, prolonged monitoring, and may lead to revision surgery
- Z-2604-2023 · Encore Medical, LP · posted Sep 19, 2023 · Open, Classified
Orthopedic device components were not subjected to final sterilization before shipment, which if implanted may lead to varying degrees of infection, which may require treatment, prolonged monitoring, and may lead to revision surgery
- Z-2605-2023 · Encore Medical, LP · posted Sep 19, 2023 · Open, Classified
Orthopedic device components were not subjected to final sterilization before shipment, which if implanted may lead to varying degrees of infection, which may require treatment, prolonged monitoring, and may lead to revision surgery
- DJO Surgical: Reverse Shoulder System (RSP) Semi Humeral Socket Insert, 32mm, REF: 508-01-032Class IIZ-2606-2023 · Encore Medical, LP · posted Sep 19, 2023 · Open, Classified
Orthopedic device components were not subjected to final sterilization before shipment, which if implanted may lead to varying degrees of infection, which may require treatment, prolonged monitoring, and may lead to revision surgery
- Z-2607-2023 · Encore Medical, LP · posted Sep 19, 2023 · Open, Classified
Orthopedic device components were not subjected to final sterilization before shipment, which if implanted may lead to varying degrees of infection, which may require treatment, prolonged monitoring, and may lead to revision surgery
- Z-2608-2023 · Philips North America Llc · posted Sep 19, 2023 · Open, Classified
Patient Information Center (PIC iX) Release 4.x Surveillance Crash Caused by Intel Graphics Driver Error-with a blank screen and subsequently require a manual reboot of the hardware to restart and continue central patient monitoring. Potential for a delay…
- Z-2609-2023 · Randox Laboratories Ltd. · posted Sep 19, 2023 · Open, Classified
there has been a transcription error in the Instructions for Use (IFU) for the Liquid Assayed Chemistry Control Premium Plus Level 3. For Caeruloplasmin, the one and two standard deviation values printed on the sheet are incorrect, which may lead to…
- Z-2610-2023 · Tytek Medical Inc · posted Sep 19, 2023 · Terminated
Updated IFU to inlclude: (1) identify the risks associated with the hazard of needle decompression and (2) improve the artwork showing placement site location
- Z-2611-2023 · Tytek Medical Inc · posted Sep 19, 2023 · Terminated
Updated IFU to inlclude: (1) identify the risks associated with the hazard of needle decompression and (2) improve the artwork showing placement site location
- Z-2612-2023 · Tytek Medical Inc · posted Sep 19, 2023 · Terminated
Updated IFU to inlclude: (1) identify the risks associated with the hazard of needle decompression and (2) improve the artwork showing placement site location
- Z-2613-2023 · GE Medical Systems Information Technologies Inc · posted Sep 19, 2023 · Open, Classified
A diode on the power supply of the Prucka 3 Amplifier used with CardioLab/ComboLab systems could reach elevated temperatures and fail, then power off and become inoperable.
- Z-2614-2023 · Abbott Medical · posted Sep 19, 2023 · Open, Classified
Due to Bluetooth malfunction on a subset of Implantable Cardioverter Defibrillator (ICD) and Cardia Resynchronization Therapy Defibrillator *CRT-D) devices that were manufactured prior to April 2022 as a result of crystal component issue within the…
- Z-2615-2023 · Abbott Medical · posted Sep 19, 2023 · Open, Classified
Due to Bluetooth malfunction on a subset of Implantable Cardioverter Defibrillator (ICD) and Cardia Resynchronization Therapy Defibrillator *CRT-D) devices that were manufactured prior to April 2022 as a result of crystal component issue within the…
- Z-2593-2023 · Aquila Corporation · posted Sep 18, 2023 · Open, Classified
Defective battery pack in wheelchair cushions can overheat resulting in property damage and one possible injury.
- Z-2594-2023 · Aquila Corporation · posted Sep 18, 2023 · Open, Classified
Defective battery pack in wheelchair cushions can overheat resulting in property damage and one possible injury.
- Z-2595-2023 · MEDLINE INDUSTRIES, LP - Northfield · posted Sep 18, 2023 · Open, Classified
4.5" Iris Scissors, Sterile, Curved (DYNJ04049) are being recalled due to the potential of the tip protector to fall off. The sharp tip of the scissors could compromise the sterile barrier system by puncturing large and/or small holes that may not be…
- Z-2589-2023 · Karl Storz Endoscopy · posted Sep 15, 2023 · Open, Classified
Flexible intubation endoscopes sterility assurance can not be confirmed.
- Z-2590-2023 · ARROW INTERNATIONAL Inc. · posted Sep 15, 2023 · Open, Classified
This recall has been initiated due to reports that the product code and product name were incorrectly listed on the lidstock of affected kits.
- Z-2591-2023 · ARROW INTERNATIONAL Inc. · posted Sep 15, 2023 · Open, Classified
This recall has been initiated due to reports that the product code and product name were incorrectly listed on the lidstock of affected kits.
- Z-2592-2023 · SenTec AG · posted Sep 15, 2023 · Open, Classified
During rework of components during the manufacturing process, an additional piece of material may have been left in the device, which may result in an impact on measurement performance.
- Z-2587-2023 · Philips Medical Systems Nederland B.V. · posted Sep 14, 2023 · Open, Classified
A damaged foot switch may cause instances where no or only intermittent x-ray radiation initiation is possible.
- Z-2582-2023 · Siemens Medical Solutions USA, Inc. · posted Sep 13, 2023 · Open, Classified
If a user-generated preset for an 18L6 transducer created on a 1.0 ultrasound system is used with a 2.0 ultrasound system, the 2.0 ultrasound system will display underestimated measurement results when using an 18L6 transducer and viewing in the Dual…
- Z-2538-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2539-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- nanoDot D2DNN, Model Numbers:Class IIZ-2540-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- nanoDot D2DNN, Model Numbers:Class IIZ-2541-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- nanoDot D2DNS, Model Numbers:Class IIZ-2542-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- nanoDot D2DNS, Model Numbers:Class IIZ-2543-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- nanoDot D2DNS, Model Numbers:Class IIZ-2544-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- nanoDot D2DXN, Model Numbers:Class IIZ-2545-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- nanoDot D2DXN, Model Numbers:Class IIZ-2546-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- nanoDot D2DXS, Model Numbers:Class IIZ-2547-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- nanoDot D2DXS, Model Numbers:Class IIZ-2548-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2549-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2550-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2551-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2552-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2553-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2554-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2555-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2556-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2557-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2558-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2559-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2560-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- nanoDot D2DNN , Model Numbers:Class IIZ-2561-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- nanoDot D2DNS, Model Numbers:Class IIZ-2562-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- nanoDot D2DNN, Model Numbers:Class IIZ-2563-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2564-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2565-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2566-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2567-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2568-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2569-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2570-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2571-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2572-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- NanoDots, Model Numbers:Class IIZ-2573-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- NanoDots, Model Number 04297-000Class IIZ-2574-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2575-2023 · Landauer · posted Sep 12, 2023 · Completed
LANDAUER received reports indicating that some nanoDots may potentially be outside of the specified range of +/-5.5% accuracy. Investigation of nanoDots indicated the presence of a potential non-conformance in the Optical Stimulated Luminescence (OSL)…
- Z-2578-2023 · Instrumentation Laboratory · posted Sep 12, 2023 · Open, Classified
Sample misidentification could occur under specific conditions and patient management altered based on an incorrectly assigned result
- Z-2579-2023 · Keystone Industries · posted Sep 12, 2023 · Open, Classified
A bottle of Copaliner Solvent was inadvertently packaged into a box labeled as Copaliner Varnish (0921526) and sold as Copaliner Varnish (0921526).
- Z-2580-2023 · Keystone Industries · posted Sep 12, 2023 · Open, Classified
The Hard Line Chairside Reline Kit (570-0718) (0921940HS) was labeled as Soft Line Chairside Reline Kit (570-0717) (0921250HS) on the outer box. The contents of the Kit and the IFU enclosed with the kit were correctly labeled as Hard Line materials
- Welch Allyn Connex Spot MonitorClass IIZ-2581-2023 · Baxter Healthcare Corporation · posted Sep 12, 2023 · Open, Classified
Product is being recalled due to the improper placement of a copper tape on the back of the liquid-crystal display.
- Z-2577-2023 · Ptw-Freiburg · posted Sep 11, 2023 · Open, Classified
Generated calibration file will not be correct in case of a relative calibration of an OCTAVIUS Detector 1000 or OCTAVIUS Detector 1600, if a Tiff file or a DICOM data set is used as reference matrix. Therefore, the measurement result will be incorrect by…
- ASG-001 ↗Class IIZ-2532-2023 · Advance Medical Designs, Inc. · posted Sep 9, 2023 · Open, Classified
Ultrasound gel mislabeled with inappropriate use.
- 50-GEL20 ↗Class IIZ-2533-2023 · Advance Medical Designs, Inc. · posted Sep 9, 2023 · Open, Classified
Ultrasound gel mislabeled with inappropriate use.
- Z-2534-2023 · Advance Medical Designs, Inc. · posted Sep 9, 2023 · Open, Classified
Ultrasound gel mislabeled with inappropriate use.
- Z-2535-2023 · Advance Medical Designs, Inc. · posted Sep 9, 2023 · Open, Classified
Ultrasound gel mislabeled with inappropriate use.
- Z-2536-2023 · Advance Medical Designs, Inc. · posted Sep 9, 2023 · Open, Classified
Ultrasound gel mislabeled with inappropriate use.
- Z-2537-2023 · Advance Medical Designs, Inc. · posted Sep 9, 2023 · Open, Classified
Ultrasound gel mislabeled with inappropriate use.
- Z-2524-2023 · Medtronic Sofamor Danek USA Inc · posted Sep 8, 2023 · Open, Classified
The incorrect product labeling was applied to the product indicating the wrong size of product.
- Z-2531-2023 · Remel, Inc · posted Sep 8, 2023 · Open, Classified
On lot of Todd Hewitt Broth w/CNA (LIM) may exhibit no recovery of target organism during customer QC testing or use with patient samples
- Allura Xper series ↗Class IIZ-2402-2023 · Philips Medical Systems Nederland B.V. · posted Sep 7, 2023 · Open, Classified
A foot switch pedal may get stuck in the active position when the user releases the pedal, resulting in the emission of unintended radiation
- Azurion ↗Class IIZ-2403-2023 · Philips Medical Systems Nederland B.V. · posted Sep 7, 2023 · Open, Classified
A foot switch pedal may get stuck in the active position when the user releases the pedal, resulting in the emission of unintended radiation
- MultiDiagnost-Eleva ↗Class IIZ-2404-2023 · Philips Medical Systems Nederland B.V. · posted Sep 7, 2023 · Open, Classified
A foot switch pedal may get stuck in the active position when the user releases the pedal, resulting in the emission of unintended radiation
- Z-2519-2023 · Zimmer, Inc. · posted Sep 7, 2023 · Open, Classified
The outer package labeling and product etch are for a Size 6, however, the implant is a Size 4, and vice versa.
- Z-2522-2023 · Aomori Olympus Co., Ltd. · posted Sep 7, 2023 · Open, Classified
The Distal Attachment contain di-2-ethylhexyl phthalate (DEHP), which exceeds the permissible exposure level calculated according to ISO 10993-17: 2002
- Reusable distal attachmentsClass IIZ-2523-2023 · Aomori Olympus Co., Ltd. · posted Sep 7, 2023 · Open, Classified
The Distal Attachment contain di-2-ethylhexyl phthalate (DEHP), which exceeds the permissible exposure level calculated according to ISO 10993-17: 2002
- Z-2517-2023 · Philips Ultrasound, Inc. · posted Sep 6, 2023 · Completed
Transducer, an ultrasound system accessory, consists of two parts that are bonded together that may come apart due to chassis bonding issue, which may pose risk to users and patients of tissue damage, and electric shock if the built-in safety measures to…
- Z-2518-2023 · Aesculap Implant Systems LLC · posted Sep 6, 2023 · Open, Classified
Trocar manufactured with the shaft too long and does not meet manufacturing specifications. As a result, when used with the 30 neuroendoscope, a portion of the visual field is obscured.
- ISee Ortho-K Lens ↗Class IIZ-2515-2023 · PARAGON VISION SCIENCES, Inc · posted Sep 5, 2023 · Open, Classified
Manufactured lenses are not covered by existing FDA approval
- Fargo Ortho-K Lens ↗Class IIZ-2516-2023 · PARAGON VISION SCIENCES, Inc · posted Sep 5, 2023 · Open, Classified
Manufactured lenses are not covered by existing FDA approval
- Z-2513-2023 · Cook Vandergrift, Inc. · posted Sep 1, 2023 · Open, Classified
Sterility of device may be compromised due to breach of the chevron seal of the packaging
Class III recalls (2)
Using the device is not likely to cause health problems, but it violates FDA rules.
- Z-2576-2023 · Microbiologics Inc · posted Sep 11, 2023 · Open, Classified
One lot of KWIK STIK ANA (3 strains) QC Set is missing one of the strains, 6018P Parabacteroides distasonis.
- Z-2521-2023 · Diversatek Healthcare · posted Sep 7, 2023 · Open, Classified
GI Software labelled as revision 3.3.0 is incorrectly labeled and is in fact revision 3.2.0.
Source: FDA Medical Device Recalls and FDA enforcement reports (recall class), via openFDA. Records are grouped by the date the FDA posted them. Methodology · Not medical advice.