Medical device recalls: March 2023
The FDA posted 113 medical device recall records in March 2023, from 68 recall events by 58 companies. 6 are Class I, the most serious category.
Each product in a recall gets its own record, so one recall event can cover several records. What recall classes mean.
Companies with the most recall events
- Datascope Corp. · 5 events, 12 records, 4 Class I
- St. Jude Medical · 2 events, 7 records
- CooperVision, Inc. · 2 events, 3 records
- Brainlab AG · 2 events, 2 records
- CareFusion 303, Inc. · 2 events, 2 records
- Intuitive Surgical, Inc. · 2 events, 2 records
- Preat Corp · 2 events, 2 records
- Becton Dickinson & Company · 1 event, 8 records
FDA root cause
- Under Investigation by firm · 36
- Device Design · 15
- Process control · 11
- Software design · 8
- Labeling Change Control · 6
- Use error · 4
- Employee error · 4
- Equipment maintenance · 3
Class I recalls (6)
The most serious: a reasonable probability that using the device will cause serious health problems or death.
- Z-1189-2023 · Avanos Medical, Inc. · posted Mar 13, 2023 · Terminated
Potential for product manifold to crack during use on patients, possibly causing leaks in the respiratory circuit and can lead to the patient receiving inadequate ventilation.
- Z-1190-2023 · Avanos Medical, Inc. · posted Mar 13, 2023 · Terminated
Potential for product manifold to crack during use on patients, possibly causing leaks in the respiratory circuit and can lead to the patient receiving inadequate ventilation.
- Z-1145-2023 · Datascope Corp. · posted Mar 9, 2023 · Open, Classified
An unexpected shutdown of the IABP may occur due to a failure of the connection between the Coiled Cord cable and the Cable Assembly backplane to the Coiled Cord cable which provides the communication between the display head and base unit.
- Z-1146-2023 · Datascope Corp. · posted Mar 9, 2023 · Open, Classified
An unexpected shutdown of the IABP may occur due to a failure of the connection between the Coiled Cord cable and the Cable Assembly backplane to the Coiled Cord cable which provides the communication between the display head and base unit.
- Cardiosave HybridClass IZ-1147-2023 · Datascope Corp. · posted Mar 9, 2023 · Open, Classified
An unexpected shutdown of the IABP may occur due to loss of communication between the Executive Processor PCBA and the Video Generator PCBA. This may result in an interruption to therapy which may threaten the hemodynamic stability of the supported patient…
- Cardiosave RescueClass IZ-1148-2023 · Datascope Corp. · posted Mar 9, 2023 · Open, Classified
An unexpected shutdown of the IABP may occur due to loss of communication between the Executive Processor PCBA and the Video Generator PCBA. This may result in an interruption to therapy which may threaten the hemodynamic stability of the supported patient…
Class II recalls (106)
The device may cause temporary or medically reversible health problems, or the chance of serious harm is remote.
- Z-1302-2023 · Atrium Medical Corporation · posted Mar 30, 2023 · Open, Classified
The Instructions for Use (IFU) for the Pneumostat Chest Drain Valve and the Express Mini 500 Dry Seal Chest Drains do not provide sufficient precaution against draining the device for continued use. Additionally, the IFUs do not provide sufficient…
- Z-1303-2023 · Atrium Medical Corporation · posted Mar 30, 2023 · Open, Classified
The Instructions for Use (IFU) for the Pneumostat Chest Drain Valve and the Express Mini 500 Dry Seal Chest Drains do not provide sufficient precaution against draining the device for continued use. Additionally, the IFUs do not provide sufficient…
- Z-1308-2023 · Quidel Corporation · posted Mar 30, 2023 · Open, Classified
Kits with affected microtiter plates have the potential to produce low OD values, causing the run to fail, per the Validation requirements of the Package Insert.
- Z-1309-2023 · Elekta Instrument AB · posted Mar 30, 2023 · Open, Classified
The incorrect IFU was distributed with the devices.
- Z-1310-2023 · Iradimed Corporation · posted Mar 30, 2023 · Open, Classified
Certain Iradimed 1057 Syringe Adapter Sets, used with the MRidium MRI infusion pump, have a problem relating to a defective injection molded part which can limit the effectiveness of the syringe venting function which then can result in occlusion.
- Z-1311-2023 · Siemens Medical Solutions USA, Inc · posted Mar 30, 2023 · Open, Classified
In the event of any unintended table movement, the system may not detect the incorrect direction, could lead to the injury of a patient, staff member, operator, or equipment.
- Z-1312-2023 · Defibtech, LLC · posted Mar 30, 2023 · Open, Classified
A component of a sub-assembly used in the affected AEDs had not undergone durability and reliability testing, and if a malfunction occurs, therefore the device could fail to deliver therapy.
- Z-1290-2023 · Gaga Pro Lighting Equipment CO., · posted Mar 29, 2023 · Open, Classified
GAGA Pro LLS systems was not in compliance with the FDA's Performance Standard for laser products.
- Z-1294-2023 · Zimmer, Inc. · posted Mar 29, 2023 · Open, Classified
Update the compatibility matrix as referred to in the Instructions for Use (IFU) for the CoCr Femoral Head XS- removes the compatibility with the Epsilon Durasul Constrained Acetabular Liners from the matrix due to the range of motion in flexion/extension…
- Z-1295-2023 · Entopsis , Inc. · posted Mar 29, 2023 · Open, Classified
Presence of misleading label statements on the product label.
- Z-1296-2023 · Entopsis , Inc. · posted Mar 29, 2023 · Open, Classified
Presence of misleading label statements on the product label.
- Z-1297-2023 · Entopsis , Inc. · posted Mar 29, 2023 · Open, Classified
Presence of misleading label statements on the product label.
- Z-1298-2023 · Entopsis , Inc. · posted Mar 29, 2023 · Open, Classified
Presence of misleading label statements on the product label.
- Z-1299-2023 · Entopsis , Inc. · posted Mar 29, 2023 · Open, Classified
Presence of misleading label statements on the product label.
- Z-1300-2023 · Entopsis , Inc. · posted Mar 29, 2023 · Open, Classified
Presence of misleading label statements on the product label.
- Z-1301-2023 · Entopsis , Inc. · posted Mar 29, 2023 · Open, Classified
Presence of misleading label statements on the product label.
- Z-1291-2023 · Alcon Research, LLC · posted Mar 28, 2023 · Open, Classified
Sterility; Steril surgical procedure packs contain incomplete seals.
- Cirq Arm System 2.0Class IIZ-1292-2023 · Brainlab AG · posted Mar 28, 2023 · Open, Classified
Risk of mechanical instability due to potential manufacturing error of the device
- Z-1293-2023 · Intuitive Surgical, Inc. · posted Mar 28, 2023 · Open, Classified
Due to Universal Surgical Manipulator (USM) instrument carriage being loose as a result of the linear rail component not being manufactured within specifications.
- Z-1285-2023 · Preat Corp · posted Mar 24, 2023 · Open, Classified
Engaging titanium base contains a dimensional condition that allows vertical movement of the titanium base after the prosthetic screw is torqued to the recommended value, which if undetected and installed on the implant, may lead to abutment/screw…
- Z-1282-2023 · CooperVision, Inc. · posted Mar 23, 2023 · Open, Classified
The lenses manufactured in the affected lot were made with a misaligned axis resulting in lenses with the incorrect power.
- Z-1283-2023 · DeRoyal Industries Inc · posted Mar 23, 2023 · Open, Classified
The reason for the voluntary recall is due to shrinkage of the canister lid. This shrinkage causes the lid not to contact the outer shell to create a seal and thus, it does not create and hold vacuum.
- Z-1284-2023 · Biomet, Inc. · posted Mar 23, 2023 · Open, Classified
The outer package labeling and product etch are a 40 mm Size D liner, however, the implant is a 38 mm Size C liner.
- Z-1276-2023 · Datascope Corp. · posted Mar 22, 2023 · Open, Classified
There is an issue related to the Safety Disk not meeting a performance requirement that may impact Intra-Aortic Balloon catheter (IAB) displacement volume. This potential failure of an impacted Safety Disk may lead to slightly reduced IAB inflation during…
- Z-1277-2023 · Datascope Corp. · posted Mar 22, 2023 · Open, Classified
There is an issue related to the Safety Disk not meeting a performance requirement that may impact Intra-Aortic Balloon catheter (IAB) displacement volume. This potential failure of an impacted Safety Disk may lead to slightly reduced IAB inflation during…
- Z-1278-2023 · Datascope Corp. · posted Mar 22, 2023 · Open, Classified
There is an issue related to the Safety Disk not meeting a performance requirement that may impact Intra-Aortic Balloon catheter (IAB) displacement volume. This potential failure of an impacted Safety Disk may lead to slightly reduced IAB inflation during…
- Z-1279-2023 · Datascope Corp. · posted Mar 22, 2023 · Open, Classified
There is an issue related to the Safety Disk not meeting a performance requirement that may impact Intra-Aortic Balloon catheter (IAB) displacement volume. This potential failure of an impacted Safety Disk may lead to slightly reduced IAB inflation during…
- Z-1280-2023 · Withings · posted Mar 22, 2023 · Open, Classified
A software bug eliminated the initial ECG activation and review of the ECG under a physician. However, the device is only cleared for use under the care of a physician.
- Z-1281-2023 · Raysearch Laboratories AB · posted Mar 22, 2023 · Open, Classified
It is possible to set a non-zero collimator angle in the Virtual Simulation module. The angle will be correct in the user interface but if the plan is DICOM exported by using the VSIM Export button, the angle will not be correct in the exported RT plan. In…
- Z-1207-2023 · CareFusion 303, Inc. · posted Mar 17, 2023 · Open, Classified
Automated dispensing cabinet drawer firmware may have inadvertently been downgraded to an earlier version of drawer firmware during new device installations or device replacement upgrades, which may lead to an increased frequency of drawer failures, which…
- Attune Revision Limb Preservation System (LPS) Tibial Insert XXSM 18MM, Part Number 151760118Class IIZ-1263-2023 · DePuy Orthopaedics, Inc. · posted Mar 17, 2023 · Open, Classified
The subject product lots are being recalled because they received a higher than specified irradiation dose. This exceeds the validated range for exposure to gamma radiation of these devices and may result in changes to the implant material properties.
- Attune Revision Limb Preservation System (LPS) Tibial Insert XSM 12MM, Part Number 151760212Class IIZ-1264-2023 · DePuy Orthopaedics, Inc. · posted Mar 17, 2023 · Open, Classified
The subject product lots are being recalled because they received a higher than specified irradiation dose. This exceeds the validated range for exposure to gamma radiation of these devices and may result in changes to the implant material properties.
- Attune Revision Limb Preservation System (LPS) Tibial Insert XSM 26MM, Part Number 151760226Class IIZ-1265-2023 · DePuy Orthopaedics, Inc. · posted Mar 17, 2023 · Open, Classified
The subject product lots are being recalled because they received a higher than specified irradiation dose. This exceeds the validated range for exposure to gamma radiation of these devices and may result in changes to the implant material properties.
- Z-1266-2023 · DePuy Orthopaedics, Inc. · posted Mar 17, 2023 · Open, Classified
The subject product lots are being recalled because they received a higher than specified irradiation dose. This exceeds the validated range for exposure to gamma radiation of these devices and may result in changes to the implant material properties.
- Z-1267-2023 · DePuy Orthopaedics, Inc. · posted Mar 17, 2023 · Open, Classified
The subject product lots are being recalled because they received a higher than specified irradiation dose. This exceeds the validated range for exposure to gamma radiation of these devices and may result in changes to the implant material properties.
- Z-1272-2023 · Vapotherm · posted Mar 17, 2023 · Open, Classified
There have been reports of excessive condensation associated with certain lots of the Low Flow Disposable Patient Circuits (DPCs) used with Precision Flow System which may lead to excessive rainout.
- Z-1259-2023 · Brainlab AG · posted Mar 16, 2023 · Open, Classified
Deep Inspiration Breath Hold (DIBH) functionality may not work as specified when based on a standard-workflow Treatment Template
- Z-1260-2023 · Bard Peripheral Vascular Inc · posted Mar 16, 2023 · Open, Classified
The external diameter of the biopsy instrument is larger than the internal diameter of the coaxial needle, which could lead to: 1) Procedural delay, 2) Requirement of an additional device, 3), Needle tip breakage, if used despite incompatibility.
- Z-1261-2023 · Limacorporate S.p.A · posted Mar 16, 2023 · Open, Classified
Due to the incorrect component, that is not cleared to be marketed in the U.S., being included in its elbow prosthesis.
- Z-1262-2023 · Intuitive Surgical, Inc. · posted Mar 16, 2023 · Open, Classified
Preventative maintenance data was used to identify instrument Arms, part of surgical systems, that allow surgeons to perform surgical tasks, that may be at risk of insertion ballscrew failure, allowing for uncontrolled carriage movement along the insertion…
- In Vitro Diagnostic (IVD) PanelClass IIZ-1251-2023 · BioFire Diagnostics, LLC · posted Mar 15, 2023 · Open, Classified
Due to temperature excursions with products (products being stored outside of the required temperature specifications) that may cause a reduction in performance. The temperature excursion was as a result of shipping delays.
- In Vitro Diagnostic (IVD) PanelClass IIZ-1252-2023 · BioFire Diagnostics, LLC · posted Mar 15, 2023 · Open, Classified
Due to temperature excursions with products (products being stored outside of the required temperature specifications) that may cause a reduction in performance. The temperature excursion was as a result of shipping delays.
- In Vitro Diagnostic (IVD) PanelClass IIZ-1253-2023 · BioFire Diagnostics, LLC · posted Mar 15, 2023 · Open, Classified
Due to temperature excursions with products (products being stored outside of the required temperature specifications) that may cause a reduction in performance. The temperature excursion was as a result of shipping delays.
- Z-1254-2023 · Fenwal Inc · posted Mar 15, 2023 · Open, Classified
Potential for centrifuge packs to develop a stress leak for certain lots of Amicus MNC Apheresis kit and Amicus Exchange kit (Therapeutic Kits) on the Amicus Separator.
- Amicus Exchange Kit Therapeutics. Component of Amicus Separator multiprocedural apheresis platformClass IIZ-1255-2023 · Fenwal Inc · posted Mar 15, 2023 · Open, Classified
Potential for centrifuge packs to develop a stress leak for certain lots of Amicus MNC Apheresis kit and Amicus Exchange kit (Therapeutic Kits) on the Amicus Separator.
- Z-1256-2023 · Stryker Medical Division of Stryker Corporation · posted Mar 15, 2023 · Open, Classified
Transport Cot has insufficient volume of epoxy to assemblies installed in the head section and foot sectioning system may result in separation of head end or foot end from the cot and result in unexpected disengagement while loading/unloading or transport.
- Access Immunoassay Systems ↗Class IIZ-1257-2023 · Beckman Coulter, Inc. · posted Mar 15, 2023 · Open, Classified
An increased incidence of damage to the nut band from a new vendor (Boamax) has led to an increased volume of complaints from consignees regarding wash arm motion failures, system check failures, and/or assay performance leading to a remote probability of…
- Z-1258-2023 · Siemens Healthcare Diagnostics, Inc. · posted Mar 15, 2023 · Open, Classified
Siemens Healthineers has received customer complaints and confirmed imprecision for Quality Control (QC) and patient samples with Dimension Tacrolimus (TAC) lots GA2286, GA3047 and GA3171. The health consequences of erroneous patient results are major,…
- Recreo Hair Growth Laser Comb ↗Class IIZ-1222-2023 · OMM Imports, Inc. dba Zero Gravity · posted Mar 14, 2023 · Open, Classified
The firm distributed the laser products without affixing the warning, aperture, certification, and identification labels. In addition, the firm failed to provide safety information, reproductions and locations of the labels, and a warning statement in the…
- Z-1250-2023 · Securitas Healthcare LLC · posted Mar 14, 2023 · Open, Classified
The mobile application for Android devices downloaded from the Google Play Store do not load per specifications and function on the Android devices.
- Z-1249-2023 · Scientia Vascular, Inc. · posted Mar 13, 2023 · Open, Classified
Microcatheters for embolic coil and diagnostic agent introduction to peripheral/neuro vasculature, due to manufacturing non-conformance, and due to flush, guidewire insertion and manipulation prior to placement, may have loose particles within catheter…
- Z-1237-2023 · Becton Dickinson & Company · posted Mar 10, 2023 · Open, Classified
Nonsterile syringe potentially exposing the patient to pathogenic microorganisms and a risk of local infection.
- Z-1238-2023 · Becton Dickinson & Company · posted Mar 10, 2023 · Open, Classified
Nonsterile syringe potentially exposing the patient to pathogenic microorganisms and a risk of local infection.
- Z-1239-2023 · Becton Dickinson & Company · posted Mar 10, 2023 · Open, Classified
Nonsterile syringe potentially exposing the patient to pathogenic microorganisms and a risk of local infection.
- Z-1240-2023 · Becton Dickinson & Company · posted Mar 10, 2023 · Open, Classified
Nonsterile syringe potentially exposing the patient to pathogenic microorganisms and a risk of local infection.
- Z-1241-2023 · Becton Dickinson & Company · posted Mar 10, 2023 · Open, Classified
Nonsterile syringe potentially exposing the patient to pathogenic microorganisms and a risk of local infection.
- Z-1242-2023 · Becton Dickinson & Company · posted Mar 10, 2023 · Open, Classified
Nonsterile syringe potentially exposing the patient to pathogenic microorganisms and a risk of local infection.
- Z-1243-2023 · Becton Dickinson & Company · posted Mar 10, 2023 · Open, Classified
Nonsterile syringe potentially exposing the patient to pathogenic microorganisms and a risk of local infection.
- Z-1244-2023 · Becton Dickinson & Company · posted Mar 10, 2023 · Open, Classified
Nonsterile syringe potentially exposing the patient to pathogenic microorganisms and a risk of local infection.
- Z-1245-2023 · Maquet Cardiovascular, LLC · posted Mar 10, 2023 · Open, Classified
One (1) Fusion Bioline Vascular graft from lot 25162546, which failed guideline straightness testing, was intermingled with lot 25162549 and distributed to customers. Use of the affected graft may result in reduction of blood flow or unwanted tension…
- Z-1246-2023 · Synthes (USA) Products LLC · posted Mar 10, 2023 · Open, Classified
TFNA Femoral Nails labeled and etched as 200mm may measure 170mm in length, and TFNA Femoral Nails labeled and etched as 170mm may measure 200mm in length
- Z-1247-2023 · Synthes (USA) Products LLC · posted Mar 10, 2023 · Open, Classified
TFNA Femoral Nails labeled and etched as 200mm may measure 170mm in length, and TFNA Femoral Nails labeled and etched as 170mm may measure 200mm in length
- Z-1248-2023 · Synthes (USA) Products LLC · posted Mar 10, 2023 · Open, Classified
TFNA Femoral Nails labeled and etched as 200mm may measure 170mm in length, and TFNA Femoral Nails labeled and etched as 170mm may measure 200mm in length
- Z-1236-2023 · Carefusion 2200 Inc · posted Mar 9, 2023 · Open, Classified
Product did not meet shelf-life testing requirements resulting in a breach of the sterility of the Genesis container holding surgical equipment.
- Monaco RTP System.Class IIZ-1233-2023 · Elekta Inc · posted Mar 8, 2023 · Open, Classified
Re-optimization, after adding contours without forced density outside the external structure, may result in inaccurate dose presentation.
- Z-1234-2023 · Stryker Leibinger GmbH & Co. KG · posted Mar 8, 2023 · Open, Classified
Device was shipped without having regulatory approval.
- Sensus Healthcare Inc, SRT-100 Vision IPX 0, HFUS Module IPX 1, with software version 1.9.2 ↗Class IIZ-1235-2023 · Sensus Healthcare, Inc. · posted Mar 8, 2023 · Terminated
When the user pauses the beam delivery, the dose timer is reset (to zero), and as a result may deliver an unexpected dose to the patient.
- Z-1223-2023 · St. Jude Medical · posted Mar 6, 2023 · Open, Classified
Select CardioMEMS PA Sensors (Model CM2000) operate outside of the intended frequency range at higher elevations when readings are taken over approximately 2,000 ft. (610 meters) above sea level; operation outside of the intended radiofrequency has the…
- Z-1224-2023 · St. Jude Medical · posted Mar 6, 2023 · Open, Classified
Select CardioMEMS PA Sensors (Model CM2000) operate outside of the intended frequency range at higher elevations when readings are taken over approximately 2,000 ft. (610 meters) above sea level; operation outside of the intended radiofrequency has the…
- Z-1225-2023 · St. Jude Medical · posted Mar 6, 2023 · Open, Classified
Select CardioMEMS PA Sensors (Model CM2000) operate outside of the intended frequency range at higher elevations when readings are taken over approximately 2,000 ft. (610 meters) above sea level; operation outside of the intended radiofrequency has the…
- Z-1227-2023 · Aniara Diagnostica LLC · posted Mar 6, 2023 · Open, Classified
New warnings and precautionary statements on product labelling: Reagent 2 (R2) of BIOPHEN Protein C 5 contains the chemical substance - Cesium Chloride which changed classification and has become hazardous according to the CLP regulation ((EC) No…
- Z-1228-2023 · Covidien, LP · posted Mar 6, 2023 · Open, Classified
Affected lots have the potential for a broken sled vane, which may cause the reload to misfire leading to non-functional staple line closure, transecting tissue without forming staples, and tissue hang-up. These conditions may be associated to a delay to…
- Z-1229-2023 · Datascope Corp. · posted Mar 6, 2023 · Open, Classified
There have been reported failures of the high pressure helium regulator, which may cause a helium leak in the Cardiosave Hospital Cart. In instance of helium regulator failure, a Pump Console s internal reservoir of helium will not be replenished when…
- Z-1230-2023 · Datascope Corp. · posted Mar 6, 2023 · Open, Classified
There have been reported failures of the high pressure helium regulator, which may cause a helium leak in the Cardiosave Hospital Cart. In instance of helium regulator failure, a Pump Console s internal reservoir of helium will not be replenished when…
- Z-1231-2023 · Datascope Corp. · posted Mar 6, 2023 · Open, Classified
Firm has received reports of damaged, worn, or torn O-rings on the Cardiosave Pump Console quick disconnect fitting, which results in helium tank leaks. If the helium supply is depleted, therapy will be interrupted.
- Z-1232-2023 · Datascope Corp. · posted Mar 6, 2023 · Open, Classified
Firm has received reports of damaged, worn, or torn O-rings on the Cardiosave Pump Console quick disconnect fitting, which results in helium tank leaks. If the helium supply is depleted, therapy will be interrupted.
- Z-1211-2023 · Linet Spol. S.r.o. · posted Mar 4, 2023 · Open, Classified
Labeling being updated to assure user is securing the siderail to a locked position to prevent potential patient fall and injury.
- Z-1209-2023 · DiaSorin Molecular LLC · posted Mar 3, 2023 · Open, Classified
Direct amplification Discs , used with COVID-19 and Flu A/B & RSV assays, may leak and cause contamination, cross-contamination, invalid results, and error codes.
- Z-1210-2023 · DiaSorin Molecular LLC · posted Mar 3, 2023 · Open, Classified
Direct amplification Discs , used with COVID-19 and Flu A/B & RSV assays, may leak and cause contamination, cross-contamination, invalid results, and error codes.
- Z-1212-2023 · LetsGetChecked Inc. · posted Mar 3, 2023 · Open, Classified
Users received sample collection kits that were assigned to another user. Incorrect shipping labels were applied to the collection kits. As a result, a number of users received sample collection kits that were assigned to another user resulting in a…
- Z-1213-2023 · Baxter Healthcare Corporation · posted Mar 3, 2023 · Open, Classified
MiniCap Disconnect Cap with Povidone-Iodine are packaged in foil pouches, which may have been incorrectly sealed, i.e., the pouches may have open or weak seals. This could lead to exposure to air, resulting in insufficient iodine/dry sponge inside the…
- epoc Host 2 as follows:Class IIZ-1214-2023 · Siemens Healthcare Diagnostics Inc · posted Mar 3, 2023 · Open, Classified
pO2 High Recovery in Quality Control When Adjusted for Barometric Pressure
- epoc Host 2 as follows:Class IIZ-1215-2023 · Siemens Healthcare Diagnostics Inc · posted Mar 3, 2023 · Open, Classified
pO2 High Recovery in Quality Control When Adjusted for Barometric Pressure
- LATITUDE NXT Remote Patient Management System, LATITUDE NXT System Server Software Model 6460.Class IIZ-1216-2023 · Boston Scientific Corporation · posted Mar 3, 2023 · Open, Classified
Under specific circumstances, the U.S. product registration system did not send up enablement requests to U.S. LATITUDE Customer Support during an 8-month interval in 2022. For these patients, the HeartLogic Index and any associated Yellow Alerts are…
- Z-1217-2023 · HeartSine Technologies Ltd · posted Mar 3, 2023 · Open, Classified
Automated external defibrillators were potentially distributed with the incorrect language configuration, which can lead to a delay in therapy or no therapy.
- Z-1218-2023 · St. Jude Medical · posted Mar 3, 2023 · Open, Classified
Radiated Radiofrequency (RF) emissions of the CardioMEMS Patient Electronics Systems (PES) Models CM1000, CM1010 and CM1100 and CardioMEMS Hospital Electronics Systems (HES) Model CM3000 exceed certain emissions limits and have the potential to cause…
- Z-1219-2023 · St. Jude Medical · posted Mar 3, 2023 · Open, Classified
Radiated Radiofrequency (RF) emissions of the CardioMEMS Patient Electronics Systems (PES) Models CM1000, CM1010 and CM1100 and CardioMEMS Hospital Electronics Systems (HES) Model CM3000 exceed certain emissions limits and have the potential to cause…
- Z-1220-2023 · St. Jude Medical · posted Mar 3, 2023 · Open, Classified
Radiated Radiofrequency (RF) emissions of the CardioMEMS Patient Electronics Systems (PES) Models CM1000, CM1010 and CM1100 and CardioMEMS Hospital Electronics Systems (HES) Model CM3000 exceed certain emissions limits and have the potential to cause…
- Z-1221-2023 · St. Jude Medical · posted Mar 3, 2023 · Open, Classified
Radiated Radiofrequency (RF) emissions of the CardioMEMS Patient Electronics Systems (PES) Models CM1000, CM1010 and CM1100 and CardioMEMS Hospital Electronics Systems (HES) Model CM3000 exceed certain emissions limits and have the potential to cause…
- Z-1201-2023 · Biomerieux Inc · posted Mar 2, 2023 · Open, Classified
For users with MYLA V4.8.X / V4.9 that use VITEK MS to identify organisms as part of their workflow, AST filter rules that have been activated are not always being applied to AST results when sending the results to the clinician.
- Z-1202-2023 · Sedecal SA · posted Mar 2, 2023 · Open, Classified
Sedecal was informed of 3 incidents of erratic movements related to X-ray mobile systems.
- Z-1203-2023 · Sedecal SA · posted Mar 2, 2023 · Open, Classified
Sedecal was informed of 3 incidents of erratic movements related to X-ray mobile systems.
- Med-Riser MR600 Patient LiftClass IIZ-1204-2023 · Med-Mizer, Inc. · posted Mar 2, 2023 · Open, Classified
Risk of boom pivot failing due to the nut securing the boom becoming loose and the bolt to be unsecure to the flange on the side.
- Sit to Stand STS500 Patient LiftClass IIZ-1205-2023 · Med-Mizer, Inc. · posted Mar 2, 2023 · Open, Classified
Risk of boom pivot failing due to the nut securing the boom becoming loose and the bolt to be unsecure to the flange on the side.
- Z-1206-2023 · Carestream Health, Inc. · posted Mar 2, 2023 · Open, Classified
After pressing and releasing the Z-Axis Motorized buttons on the Tube Head Display, the Overhead Tube Crane (OTC) could potentially continue the movement unexpectedly to a certain distance which could potentially result in a injury
- Z-1208-2023 · Coltene Whaledent Inc · posted Mar 2, 2023 · Open, Classified
Screw connection between the turbine head and the push button may loosen and fall off during the treatment, and increase the risk of swallowing or inhaling part of the turbines head or the push button
- Z-1191-2023 · Stryker GmbH · posted Mar 1, 2023 · Open, Classified
Stryker has identified a nonconformance in specific lots of Hoffmann LRF Bone Transport Struts. Specifically, the thread pitch is oversized at the distal end of the threaded rod, and as a result the distal ring fixation cannot be locked between 0- 50mm of…
- Z-1192-2023 · CareFusion 303, Inc. · posted Mar 1, 2023 · Open, Classified
Infusion pump PCs with specific software/network cards/IP addresses can have network/wireless connection failure. Could cause inability to receive new datasets and inability to transfer retrospective analytics data to connected systems. Users with…
- Z-1193-2023 · Unetixs Vascular, Inc. · posted Mar 1, 2023 · Open, Classified
The current luer fittings and adaptors allow for the possibility of the air line to be misconnected to an intravenous line, which may cause an air embolism.
- Z-1194-2023 · Unetixs Vascular, Inc. · posted Mar 1, 2023 · Open, Classified
The current luer fittings and adaptors allow for the possibility of the air line to be misconnected to an intravenous line, which may cause an air embolism.
- MultiLab Series II ROODRA non-invasive vascular diagnostic device, Model Number 11986-0000-01 ↗Class IIZ-1195-2023 · Unetixs Vascular, Inc. · posted Mar 1, 2023 · Open, Classified
The current luer fittings and adaptors allow for the possibility of the air line to be misconnected to an intravenous line, which may cause an air embolism.
- MultiLab Series II REVO non-invasive vascular diagnostic device, Model Number 12950-0000-01 ↗Class IIZ-1196-2023 · Unetixs Vascular, Inc. · posted Mar 1, 2023 · Open, Classified
The current luer fittings and adaptors allow for the possibility of the air line to be misconnected to an intravenous line, which may cause an air embolism.
- Z-1197-2023 · CooperVision, Inc. · posted Mar 1, 2023 · Open, Classified
Manufactured with misaligned axis resulting in lenses with the incorrect power, users may experience poor visual acuity
- Biofinity XR Toric Single Diagnostic lens- Soft (hydrophilic) Contact Lens (extended wear) ↗Class IIZ-1198-2023 · CooperVision, Inc. · posted Mar 1, 2023 · Open, Classified
Manufactured with misaligned axis resulting in lenses with the incorrect power, users may experience poor visual acuity
- Z-1199-2023 · Beaver Visitec International, Inc. · posted Mar 1, 2023 · Open, Classified
Device packaging may contain open seals, compromising product sterility.
- CustomEyes kits ↗Class IIZ-1200-2023 · Beaver Visitec International, Inc. · posted Mar 1, 2023 · Open, Classified
Device packaging may contain open seals, compromising product sterility.
Class III recalls (1)
Using the device is not likely to cause health problems, but it violates FDA rules.
- Z-1226-2023 · Preat Corp · posted Mar 6, 2023 · Open, Classified
Product is labeled with an incorrect expiration date.
Source: FDA Medical Device Recalls and FDA enforcement reports (recall class), via openFDA. Records are grouped by the date the FDA posted them. Methodology · Not medical advice.